Iniciar sesión:
Votos - 5, Puntuación media: 4.8 ( )

Manual de usuario KitchenAid, modelo 2005

Fabricar: KitchenAid
Tamaño del archivo: 493.14 kb
Nombre del archivo: 9763380.pdf
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Remove the power supply cable knockout using a flat-blade screwdriver. Attach strain relief in power supply cable opening so that clamping screws are inside of range hood. Tip hood back to its bottom surface. 2. If roof or wall cap does not have a damper, attach damper to exhaust opening on top of the range hood using 2 small screws from hardware package. 3. Place the range hood mounting screws close to the holes in the cabinet bottom. 4. Lift range hood into place while feeding wiring through strain relief. 5. Insert the screws through the clearance holes and start them into the hood. Then, tighten screws securely. 6. Connect vent system, for either vented or recirculating, to range hood. 7. Seal all joints with duct tape. 8. For recirculating installations, install the vent cover included in Recirculation Kit Part Number 4396565 in soffit or cabinet top vent opening. Make Electrical Connection WARNING Electrical Shock Hazard Disconnect power before servicing. Replace all parts and panels before operating. Failure to do so can result in death or electrical shock. 1. Disconnect power at the circuit breaker of fused circuit box. 2. Connect the white wire of the power supply cable with the white lead in the range hood using a twist-on connector. 3. Connect the black wire of the power supply cable with the black lead in the range hood using a twist-on connector. WARNING Electrical Shock Hazard Electrically ground blower. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. 4. Connect the green power supply ground wire to the unused, green ground screw. D E A B C F A. Green ground screw B. Hood wiring C. White wires D. Twist-on connectors E. Black wires F. Power supply cable 5. Tighten strain relief screws. 6. Replace the terminal box cover. Install Filters 1. For recirculating installations only, install the charcoal filters included in Recirculation Kit Part Number 4396565. Place the charcoal filter against the blower cover and rotate to the right (clockwise) to attach to cover. Repeat with other charcoal filter. A A. Filter 2. Replace metal filter. Turn knob on metal filter to the right (clockwise) to attached to range hood. Check Operation 1. Check operation of the range hood by turning on the power. 2. The range hood controls are located on the right-hand underside of the range hood. A B A. Controls B. Filters 3. Move the light switch to “1” position. The light should turn on. 4. Move blower switch to “1” position. The blower should operate. 5. Move the blower speed switch to “1” position for low speed, “2” position for medium speed or “3” position for high speed. 6. Move blower and light switches to “0” position to turn blower and light off. 7. If range hood does not operate, check to see whether a circuit breaker has tripped or a household fuse has blown. Disconnect power supply and check that the wiring is correct. NOTE: To get the most efficient use from your new range hood, read the “Range Hood Use” section. RANGE HOOD USE The range hood is designed to remove smoke, cooking vapors and odors from the cooktop area. For best results, start the hood before cooking and allow it to operate several minutes after the cooking is complete to clear all smoke and odors from the kitchen. The hood controls are located on the right-hand underside of the range hood. A BCD A. Controls B. Light switch C. Blower switch D. Blower speed switch Range HoodControls Operating the light 1. Move the light switch to the “1” position to turn range hood light ON. 2. Move the light switch to the “0” position to turn range hood light OFF. Operating the blower 1. Move the blower switch to the “1” position to turn the blower ON. The blower will begin operating at the speed set on the blower speed switch. 2. Move the blower switch to the “0” position to turn the blower OFF. Adjusting the blower The blower has 3 speed controls. Move the blower speed switch to “1” position for low speed, “2” position for medium speed or “3” position for high speed. RANGE HOOD CARE Range Hood Lamps Replacing a Halogen Lamp This hood uses four 12-volt, 20-watt halogen lamps. Turn off the range hood and allow the hallogen lamps to cool. Replace bulb using a tissue to handle bulb, or wearing cotton gloves. Do not touch bulb with bare fingers. To Replace: 1. Disconnect power. 2. Remove 2 screws from the circular metal trim around the lamp assembly. 3. Pull the trim and lamp assembly down far enough so that the lamp can be pulled out of the socket clips. A A B A. Remove 2 screws B. Pull trim with lamp assembly down 4. Insert the new lamp into the socket clips and push the lamp assembly back up into the hood. 5. Replace the screws. 6. Reconnect the power. Cleaning Exterior surfaces: Do not use steel wool or soap-filled scouring pads. Rub in direction of the grain line to avoid scratching the surface. Always wipe dry to avoid water marks. ¦ Stainless Steel Cleaner & Polish. ¦ Mild liquid detergent a...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría