Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario KitchenAid, modelo Pro Line Pro LineTM Range Hood

Fabricar: KitchenAid
Tamaño del archivo: 574.28 kb
Nombre del archivo: 9763385.pdf
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


to cooking surface 48" (121.9 cm) hood 5a.Optional vent cover installation: Attach the full-width vent cover to the top of the range hood with the screws provided. The vent cover must be attached to the top of the range hood before mounting the range hood to the wall. CL Top (27.9 cm) of hood 11" A B CL Mounting brackets A 30" (76.2 cm) hood: 13-15/32" (34.2 cm) 36" (91.4 cm) hood: 16-15/32" (41.8 cm) 42" (106.7 cm) hood: 19-15/32" (49.4 cm) 48" (121.9 cm) hood: 22-15/32" (57.1 cm) B 30" (76.2 cm) hood: 26-15/16" (68.4 cm) 36" (91.4 cm) hood: 32-15/16" (83.7 cm) 42" (106.7 cm) hood: 38-15/16" (98.9 cm) 48" (121.9 cm) hood: 44-15/16" (114.1 cm) Install each bracket on the wall as shown. Make sure that the screws and brackets are securely fastened to the wall. Install only the brackets. Do not install the hood. 5b. If chimney extension is used: Attach the extension brackets as shown. 10-5/8" ceiling (27 cm) 8-1/8" (20.6 cm) 8-1/8" (20.6 cm) brackets top of hood 23" (58.4 cm) max. 12" (30.5 cm) min. Make sure that the screws are securely fastened to the wall. 6. Determine and make all necessary cuts in the wall for the vent system. Install the vent system before the canopy hood. See venting methods on Page 4, and hood vent opening dimensions on Page 6. 7. Determine the required height for the power supply cable and cut a 1-1/4" (3.2 cm) hole at this location. Run wire through hole according the National Electrical Code or CSA Standards and local codes and ordinances.There must be enough power supply cable from the fused disconnect (or circuit breaker) box to make the connection in the hood’s electrical box. Use caulking to seal all openings. Do Not turn on power until installation is completed. 8. Remove the terminal box cover from the canopy hood. Remove the power supply cable knockout using a flat-blade screwdriver. Attach conduit connector into power supply cable opening so that conduit connector clamping screws are inside of canopy hood. WARNING Excessive Weight Hazard Use two or more people to move and install range hood. Failure to do so can result in back or other injury. 9. If roof or wall cap does not have a damper, attach damper to exhaust opening(s) on top of the hood using two Phillips-head screws. 10. If 48" (121.9 cm) hood is to be connected to 10" (25.4 cm) round vent system, install the vent transition piece now. bracket V1 V2 wall mounting hood screw 30" (76.2 cm) hood has two brackets 36" (91.4 cm) hood has two brackets 42" (106.7 cm) hood has four brackets 48" (121.9 cm) hood has four brackets 11. The hood attaches to the wall by screws discussed earlier in the installation instructions at Step 5.The hood hangs from these screws by brackets inside the range hood. Before attempting to hang the hood, use a Phillips screwdriver to rotate the adjustment screw marked V1 counterclockwise to extend the brackets from the canopy. Hang the range hood by inserting the brackets into the mounting screws as shown. Note: These screws must be installed into solid wood to support the weight of the hood as described in Step 5. Rotate the screws marked V1 to tighten the range hood against the wall. Make sure that the range hood is securely tightened against the wall. 12. The brackets are also used to adjust the level of the canopy. Using a Phillips screwdriver, rotate the screw V2 to adjust the level of the canopy. 13. Connect vent system to hood. Seal all joints with duct tape. 14. If your installation uses the optional vent cover, fit the cover flanges over the brackets. If installation uses the chimney extension, fit the extension over the brackets. Install the upper section first, then fit the lower section over the upper section. Seal extension to hood with duct tape. Electrical connection WARNING Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. 15. Make electrical connection: . Connect the power supply cable to hood terminal box through the U.L.- or C.S.A.-listed conduit connector. . Connect the white wire of the power supply cable with the white lead in the hood using a twist-on connector; connect the black wire of the power supply cable with the black lead in the hood using a twist-on connector. . Connect the power supply green ground wire under the green, ground screw. . Tighten conduit connector screws. . Replace the terminal box cover. 16. Install the filters. • Remove the filters from the box and remove the white protective coating from the filters. Note: Use two hands to install filter, one to pull and turn the knob, the other to hold the filter in place so that it doesn’t fall onto the cooktop. • Grasp one of the filters so that the knob faces down and toward the back of the hood. • Insert the filter end without the knob into the retaining channel in the front of the hood. • Pull and turn the knob to the left (counterclockwise) so that the locking...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría