Iniciar sesión:
Votos - 4, Puntuación media: 4.3 ( )

Manual de usuario NuTone, modelo 672R

Fabricar: NuTone
Tamaño del archivo: 280.18 kb
Nombre del archivo:
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


FAN MUST NOT BE INSTALLED IN A CEILING INSULATED TO A VALUE GREATER THAN R-40. SUITABLE FOR USE OVER TUB OR SHOWER ENCLOSURE WHEN INSTALLED IN A GFCI PROTECTED BRANCH CIRCUIT. FOR BEST RESULTS When installing the Exhaust Fan in a new construction site, install the housing during the rough-in construction. The blower unit and grille should be installed after the finished ceiling is in place. To install the Exhaust Fan in an existing finished building, an accessible area is required above the planned location (attic or crawl space). IMPORTANT SAFETY INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE. ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have questions, contact the manufacturer. B. Before servicing or cleaning unit, switch power off at service panel and lock service panel to prevent power from being switched on accidentally. When the service disconnecting means cannot be locked, securely fasten a prominent warning device, such as a tag, to the service panel. CAUTION: For general ventilating use only. Do not use to exhaust hazardous or explosive materials and vapors. WARNING: To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control. INSTALLATION INSTRUCTIONS WARNING: TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Installation work and electrical wiring must be done by qualified person(s) in accordance with all applicable codes and standards, including fire-rated construction. B. Sufficient air is needed for proper combustion and exhausting of gases through the flue (chimney) of fuel burning equipment to prevent back drafting. Follow the heating equipment manufacturer's guideline and safety standards such as those published by the National Fire Protection Association (NFPA), and the American Society for Heating, Refrigeration and Air Conditioning Engineers (ASHRAE), and the local code authorities. DUCT COLLAR HOUSING MOUNTING TAB COLLIER DE GAINE BOITER PATTES DE MONTAGE SLOTS FENTES POWER UNIT/BLOWER ASSEMBLY TABS GRILLE ENSEMBLE MOTEUR/ VENTILATEUR LA GRILLE PATTES FIGURE 1 C. When cutting or drilling into wall or ceiling, do not damage electrical wiring and other hidden utilities. D. Ducted fans must always be vented to the outdoors. E. If this unit is to be installed over a tub or shower, it must be marked as appropriate for the application and be connected to a GFCI (Ground Fault Circuit Interrupter) protected branch circuit. F. NEVER place a switch where it can be reached from a tub or shower. PLANNING DUCTWORK AND WIRING DUCT COLLAR Ductwork 1. Use 4" round duct. 2. Plan to run duct from discharge opening of fan to the outside. For best fan performance, make the duct run as short as possible and use a minimum number of elbows. 3. Use optional ducting accessories as required. Wiring Plan to run 120vAC house wiring (with ground) from the power source through a standard wall switch. Preparation 1. Refer to Figure 1. Remove blower/power unit assembly from the housing. (a) Unplug the power unit. (b) Remove the screw (located next to plug-in receptacle) which holds blower/power unit mounting plate in place. Do not misplace this screw. (c) Lift the mounting plate at the end near the plug-in receptacle until blower wheel clears the scroll. (d) Remove plate by pulling its tabs out of slots in the housing. Set blower/power unit aside until needed. 2. Remove one of the wiring knockouts from housing. MOUNTING THE HOUSING Mounting Using Mounting Tabs Refer to Figure 2. 1. Locate fan housing next to ceiling joist. 2. Using wood screws (not provided) loosely attach the housing to ceiling joist through the keyhole slots in mounting tabs. 3. Adjust housing so that it will be flush with the finished ceiling. For the grille to fit properly, the housing’s rim must not extend beyond finished ceiling surface. 4. When housing is properly adjusted, tighten screws in slots. Mounting Using Hanger Bars (hanger bars sold separately, ...

Otros modelos de este manual:
Los aficionados - 671R (280.18 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría