Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Hunter Fan, modelo PERFECT WINDOW ER150

Fabricar: Hunter Fan
Tamaño del archivo: 508.58 kb
Nombre del archivo: 0bc1a7cb-7a27-4cde-983a-5adaf3acbe66.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


At the end of the 25-minute run cycle, when the core can experience some nominal frost buildup, the timer activates a motor-driven damper door that simultaneously opens the defrost port and closes off the supply air port. . DUCTING (4 PORTS) MAIN MOTOR SQUIRREL CAGE FAN CORE GUIDE CHANNEL (4) DRAIN PANS INSULATED ACCESS DOOR PLATE (2) M29852 DEFROST DAMPER (MOTOR AND DOOR) CABINET FILTERS (2) DRAIN P TRAP DRAIN LINE DOOR KEEPER DEFROST PORT (NON-DUCTED) CORE INSTRUCTIONS ENERGY TRANSFER CORE 69-1188—03 4 5a. Energy Transfer Core 5a. Energy Transfer Core 5b. Heat Transfer Core As the exhaust and fresh air pass through opposite sides of the Heat Transfer Core heat is transferred from the warm side to the cold side. This heat transfer reduces the cost of conditioning the fresh outside air that is brought into your home. This increases the temperature of the fresh air brought inside in the winter and cools the fresh air brought inside in the summer. The core removes easily for cleaning. Operating your Fresh Air Ventilation System Changing Fan Speed Depending on the control installed with your ERV, you might be able to change the fan speed. Check the manual of your control for more information. Connecting a Remote Device Your ventilator comes equipped with a low voltage terminal strip for connection to several optional control devices. EXTERNAL REMOTE WALL CONTROL (DEHUMIDISTAT) The dehumidistat (connected to your ventilator) is designed to control the operation of the ventilator fan to help keep the humidity level in your home comfortable. If an independent humidifier is installed and set at 30% (a normal indoor winter level) then the dehumidistat (for the ventilator) should be set at least 10% higher, in this case 40%. With the ventilator operating on low speed and no one at home to produce humidity, the humidifier will keep the humidity level at its setpoint. If the humidity levels rise (due to occupant activity) above the 40% level, then the dehumidistat will automatically increase the speed of the ventilator fan to high until the humidity level falls below 40%. NOTE: During the winter months, the air inside your home usually contains more moisture than the outside air even though the outside relative humidity is higher than the inside relative humidity. The ventilator will automatically turn off the dehumidistat feature during the summer months when the outside air contains more moisture than the inside air. TIMER For your convenience, Honeywell provides an optional timer control that can fit a wide variety of needs, for example, exhaust humid air from the bathroom or kitchen (see the timer instructions for selection and part numbers). 5 69-1188—03 WALL SWITCH WALL SWITCH The remote device can be wired to run the ventilator at either the high or low speed. Getting the most from your Fresh Air Ventilation System HOW MUCH VENTILATION DO I NEED? During the seasons that your windows and doors are closed (winter and summer if you have air conditioning), the ventilator should operate continuously when the home is occupied, and either continuously or intermittently when not occupied. For most installations, the ventilator will normally be set to operate continuously on low speed with the option of going to high speed as the need arises. For example, if you are entertaining and there is a large...

Otros modelos de este manual:
Los aficionados - PERFECT WINDOW ER150 (508.58 kb)
Los aficionados - PERFECT WINDOW ER200 (508.58 kb)
Los aficionados - PERFECT WINDOW ER200 (508.58 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría