Iniciar sesión:
Votos - 5, Puntuación media: 4.6 ( )

Manual de usuario Hunter Fan, modelo 82048

Fabricar: Hunter Fan
Tamaño del archivo: 4.94 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


B20 B21 F G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. B22 B22 ENGLISH H H Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. Connect wiring from the motor to the wiring cover plate. B25 B24 I Turn on the power source. Secure the motor by tightening the 2 screws. B26 B27 Go to step on page 18 to attach grille. ON E1 OFF Test the motor. If the motor does not run, check the plug connection. 8”8.5” Existing Construction – accessible from above C11 EXISTING FAN NO EXISTING FAN ENGLISH OR Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). Use the motor housing as a template to mark position. C12 E D Cut out an opening for the housing. Slide the mounting rails into brackets. 5/81/25/81/2 1/8" Bit C13 C14 Position the correct depth mark at the bottom edge of the joist based on the thickness of your sheetrock. Mark position of screws by using holes as a template. C16 C15 ENGLISH Drill a hole in the center of each outline. Insert screws, leaving space between the screw head and the joist. Screws are not provided. C18 C17 Attach the rails onto the screws. Tighten screws. C19 C20 Connect 4” duct and vent to the outside. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. Pull wires through the strain relief. C21 ENGLISH Tighten the strain relief screws. C22 Ground Black Green 2 Pin A Bare Copper White Black Main Switch 1 (AC In) Fan Motor White F White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. C24 C23 H F G Install the wiring cover plate. Make sure all wiring connections are inside the box or under the wiring cover plate. Connect wiring from motor the motor to the wiring cover plate. C25 C26 ENGLISH H I Secure the motor by tightening the 2 screws. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. C28 C28 C27 ON OFF Test the motor. If the motor does not run, check the plug connection. Turn on the power source. C29 Go to step on page 18 to attach grille. E1 21 Existing Construction – accessible only from below D11 D12 EXISTING FAN ENGLISH E Move the housing into position above the ceiling. Remove an existing fan and check to make sure the opening is large enough to accommodate the new motor housing (8”x 8.5”). D13 D14 Pull wires through strain relief. Attach existing ducting to duct connector. Tape joints. If ducting does not fit securely, an adapter may need to be purchased. D15 E Install the housing flush with the sheetrock and secure by tightening the pre-loaded screws into the joist. D16 Ground ENGLISH Black Green 2 Pin A Bare Copper White Black Main Switch 1 (AC In) Fan Motor White F White 3 Pin Black Light Light *Option Black Switch 2 (AC In) *Option Fan & Main Light Together Connect wires as shown. D18 D17 F H G Connect wiring from the motor to the wiring cover plate. Install the wiring cover plate. D19 D20 H I Secure the motor by tightening the 2 screws. Reinstall the motor by inserting the tabs and pushing up into position. Make sure the wires are not pinched between the motor and the housing. D22 D21 ENGLISH ON OFF Test the motor. If the motor does not run, check the plug connection. Turn on the power source. D23 Go to step on page 18 to attach grille. E1 E1 E2 L K Remove the thumbscrews. Connect wiring harness. E4 E3 ENGLISH J K Remove the strain relief bracket screw. Position the strain relief bracket under the motor as shown. E6 E5 Align posts A, B, C and D (stamped into motor housing) with posts A, B, C and D (stamped into light fixture). Slide light fixture over posts. Insert the strain relief bracket’s dog-leg tab so that it hooks over the lip of the motor. Reinstall the strain relief bracket screw. E8 E7 N Attach thumbscrews. WARNING: To reduce the risk of electrical shock, all 4 thumbscrews MUST be properly installed. Install 2 Max 60 Watt A15 bulbs (Not Included). E10 E9 ENGLISH O M Align glass dome and push up. Screw glass stop into position. E11 E12 P Complete. Screw Finial into position Trouble Shooting Problem: Fan does not come on. Solution: • Hunter Fan Bath Ventilators are extremely quiet. To confirm that the fan is running, place your hand near the vents to feel the air movement. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the wiring to make sure it matches the wiring diagram. Problem: Light does not come on. Solution: • Replace the light bulb with a new bulb. • Turn power on, replace fuse, or reset breaker. • Check all plug connections to be sure they are secure. • Check the ...

Otros modelos de este manual:
Los aficionados - 43042-01 (4.94 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría