|
Resumen del manual
10 Electrical The HRV unit should be plugged into a standard designated (120VAC) electrical outlet with a ground. The outlet should be serviced by a separate 15 amp/120V circuit. An extension cord should not be used with this appliance. A qualified service technician should make any required electrical connections. Remote Control Connections Prior to connecting remote devices, it is advisable to run self test on the HRV/ERV. Low voltage connections between the remote controls, the dehumidistat, or the fan timer should be made by a qualified service technician. Low voltage wires from the remote controls are connected to the HRV micro-processor board. In order to prevent electric shock when cleaning or servicing the HRV, it is extremely important to confirm the polarity of the power line that is switched by the safety (disconnect) switch. The hot line (black) is the proper line to be switched. To confirm the proper polarity, use a voltmeter or test lamp to ensure there is no power after the switch when the door is open. Check between that point and ground (on the cabinet). Always make sure that the HRV is properly grounded. WARNING 11 Ventilation Dehumidistat PART NO. 99-116 The High/Low Speed Switch initiates High or Low speed ventilation. This control also has an ON/OFF Switch and a Dehumidistat Dial (refer to "The ON/OFF Switch" and "The Dehumidistat Dial" descriptions). Recirculation Control PART NO. 99-RECIRC Note: For use with RNC5-TPD only The Recirculation Switch will toggle from continuous low speed ventilation to recirculation mode (closes the fresh air damper and circulates the building air). The Dehumidistat Dial will initiate High Speed ventilation when the indoor humidity level exceeds the set point (regardless position of the RECIRC Switch.). This control also has an ON/OFF Switch and a Dehumidistat Dial (refer to "The ON/OFF Switch" and "The Dehumidistat Dial" descriptions). Remote Control Devices 20 Minute Timer PART NO. 99-132 Connects to RED, BLACK and GREEN (LED drive) terminals. Use a minimum of three 20 gauge low voltage wire. Connect up to 4 on 100 ft (91 m) wire max. Mounts in a 2 x 4 box. DEHUMIDISTAT Off 10 20 30 50 40 60 Optional Main Controls The amount of ventilation required in your home will fluctuate according to the activity level in the house. Higher activity levels require more ventilation. Main controls can be mounted in a central location of the home (i.e. beside the furnace thermostat) which will provide the user with complete control over their ventilation system from a convenient location. The ON/OFF Switch The ON/OFF Switch will turn the HRV ON or OFF. Controls with an ON/OFF switch can be modified to ON/Standby by adjusting the circuit board DIP Switches (Refer to "Mode DIP Switch Settings"). The Dehumidstat Dial Main controls feature a dehumidistat dial. The dehumidistat is used to reduce high winter humidity levels. The dehumidistat activates high speed ventilation when the indoor humidity level exceeds selected setting. Optional Timers Timers should be present when the HRV is exhausting from specific locations i.e bathrooms, laundry rooms. The 20 Minute Timer is the best selection, however, the crank timer will be necessary if only 2 lead low voltage wires are present. Only one main control can be installed on your system. ATTENTION Dehumidistat Dial High/Low Speed Switch ON/OFF Switch Crank Dial Rotate the dial for up to 60 minutes high speed operation. Dehumidistat Dial Recirculation Switch ON/OFF Switch 20/40 ON/OFF Dehumidistat PART NO. 99-2040 The 20/40 Switch will toggle from continuous low speed ventilation to an intermittent mode of 20 minutes fan ON (in low speed) and 40 minutes fan OFF. The Dehumidistat Dial will initiate High Speed ventilation when the indoor humidity level exceeds the set point (regardless position of the 20/40 Switch.). This control also has an ON/OFF Switch (refer to "The ON/OFF Switch" description). Remote Dehumidistat PART NO. 99-130 White The Remote Dehumidistat activates high speed ventilation when the indoor humidty level exceeds the set point. Dehumidistat Dial 20/40 Switch ON/OFF Switch Dehumidistat Dial Crank Timer PART NO. 99-101 Connects to RED and BLACK terminals. Use a two 18 gauge low voltage wire. Mounts in a 2 x 4 box. The crank timer provides a solution to installing a system where only 2 wires are present for the timers. 20 Minute Status Lights The 20 Minute Status Light indicates high speed operation is activated. Touch Pad The Touch Pad initiates high speed operation. 12 13 Wiring the Controls Red to Red Green LED Drive to Green Black to Black DEHUMIDISTAT Red to Red Orange to Orange Black to Black Dehumidistat Ventilation Control (DVC) 20 Minute Timer (shown in a Decora Cover Plate)*** Red to Red Black to Black Remote Dehumidistat Remove factory installed jumper when installing this control* Factory installed jumper* Factory installed jumper* Circuit Board Terminal Strip** Circuit Board Terminal Strip** Circuit B...
Otros modelos de este manual:Los aficionados - RNC5-TPF (1.4 mb)