Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Air King, modelo 6C507B/9145B

Fabricar: Air King
Tamaño del archivo: 111.56 kb
Nombre del archivo: b1ae6276-cc69-4e66-b02b-1da9c21d562c.pdf
Idioma del manual:es
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This work must be done only by a qualified electrician, using copper wire only. WARNING: USE OF A THREE-PRONG TO TWO-PRONG ADAPTER IS NOT RECOMMENDED. IMPROPER CONNECTION MAY CREATE THE RISK OF ELECTROCUTION. USE OF SUCH ADAPTERS IS NOT PERMITTED IN CANADA. 3. Where possible, avoid the use of extension cords. If they must be used, minimize the risk of overheating by ensuring that they are UL listed and of the proper gage and length. Never use a single extension cord to operate more than one fan. 4. Do not insert fingers or foreign objects into the fan. Do not block or tamper with the fan in any manner while it is in operation. Rev. C (Color) 2/97 1 5. Unplug power cord before installing or servicing the fan. WARNING: DO NOT DEPEND UPON THE ON-OFF SWITCH AS THE SOLE MEANS OF DISCONNECTING POWER WHEN INSTALLING OR SERVICING THE FAN. ALWAYS UNPLUG THE POWER CORD. 6. This fan is intended for general use ONLY. It must NOT be used in potentially dangerous locations such as flammable, explosive, chemical-laden or wet atmospheres. DO NOT use fan in a window. Rain may create an electrical hazard. WARNING: TO REDUCE THE RISK OF FIRE OR ELECTRIC SHOCK, DO NOT USE THIS FAN WITH ANY SOLID STATE SPEED CONTROL DEVICE. ASSEMBLY 1. Remove T-Knob from Fan Head Assembly while being careful to retain the Hex Nut on the opposite side. ( Figure 1) 2. Insert the Fan Head Assembly into the Slot on the Clip Assembly. 3. Reinstall the T-Knob. Tighten securely. Figure 1 4. WALLMOUNT USE: Install a Screw (#8 x 3/4" Wood Screw or equivalent...not supplied) in the wall and hang the Clip Assem- Figure 2 bly on the Screw. (Figure 2) 2085299A MODEL 6C507B/9145B MANUAL DE INSTRUCCIONES DE OPERACION Y PARTES MODEL 6C507B/9145B MANUAL DE INSTRUCCIONES DE OPERACION Y PARTES OPERATION 1. Clip fan to a structure that is between 3/4" and 1 1/8" thick. Clipping the fan to structures with greater or lesser widths may lead to instability. 2. SPEED: Speed is controlled by three position rotary switch located on rear of motor housing. 3. ANGLE ADJUSTMENT: Loosen knob under fan head. Tilt head to desired air flow position. Retighten knob. 4. POWER SUPPLY CORD: Plug power supply cord into wall outlet (120V AC, 60 Hz). MAINTENANCE WARNING: ALWAYS UNPLUG THE CORD BEFORE MOVING OR SERVICING THE FAN. CLEANING Use a soft cloth moistened with a mild soap solution. Avoid use of gasoline, benzine, thinner, chlorinated solvents, harsh cleaners, etc. This will result in damge to the fan. LUBRICATION Precision bearings are sealed at the factory for life and will not require any further lubrication. STORAGE When not in use, keep unit in a clean, dry place. 1920 WARNING: TO AVOID THE RISK OF FIRE OR ELEC- TRIC SHOCK, DO NOT USE FAN WITH ANY SOLID STATE SPEED DEVICE. REPLACEMENT PARTS LIST REF NO. PART NO. DESCRIPTION QTY. REF NO. PART NO. DESCRIPTION QTY. 1 2011739 Ornament 1 14 2091138 Rear Motor Cover Screw 2 2 2096065 Front Grill 1 15 2011724 Switch Knob 1 3 2011754 Fan Blade 1 16 2050099W Cordset 1 4 2090588 Blade Clamp 1 17 2011704A Adjustment Knob 1 5 2090123 M4 Hex Nut 2 18 2011397 Neck 1 6 2091156 8-32 Hex Nut 1 19 2009102 Foot 2 7 2011684 Motor Housing & Rear Grill 1 20 2091116 Screw #8 x 5/8 HWH 1 8 2030078H Motor Assembly 1 Type 25 9 2090117 Lockwasher #8 Ext. Tooth 1 21 2091149B Clip Spring 1 10 2091119 #6 x 3/8" Ground Screw 1 22 2011377 Top Clip 1 11 2057062 Switch 1 23 2011387 Bottom Clip 1 12 2011764 Rear Motor Cover 1 VENTILADOR DE MORDAZAS DE 6" (15.2 cm) MODELO 6C507B/9145B LEA Y GUARDE ESTAS INSTRUCCIONES LEALAS CUIDADOSAMENTE ANTES DE INTENTAR ARMAR, INSTALAR, OPERAR O DAR MANTENIMIENTO AL PRODUCTO DESCRITO. PROTEJASE A SI MISMO Y A LOS DEMAS OBSERVANDO TODA LA INFORMACION SOBRE SEGURIDAD. .NO SEGUIR LAS INSTRUCCIONES PODRIA RESULTAR EN LESIONES PERSONALES Y/O DANOS A LA PROPIEDAD! GUARDE LAS INSTRUCCIONES PARA REFERENCIAS FUTURAS. DESCRIPCION 5. Desenchufe el cordon electrico antes de instalar o dar servicio al El ventilador AirKing de mordazas de 6" (15.2 cm) es de operacion ventilador. silenciosa, tiene un control de conjuntor rotatorio, inclinacion vertical ADVERTENCIA: NO DEPENDA DEL INTERRUPTOR DE ENCENDIDO ajustable y un movimiento de la cabeza de 360°. Su unidad giratoria de 3 Y APAGADO COMO EL UNICO MEDIO PARA INTERRUMPIR LA paletas, de seis pulgadas (15.2 cm), es accionada por un motor ALIMENTACION ELECTRICA CUANDO INSTALE O DE SERVICIO AL permanentemente prelubricado. VENTILADOR. SIEMPRE DESENCHUFE EL CORDON ELECTRICO. 6. Este ventilador es para uso general EXCLUSIVAMENTE. NO debera ESPECIFICATIONES Y FUNCIONAMIENTO usarse en localidades potencialmente peligrosas tales como atmosferas inflamables, explosivas, cargadas de gases o humedas. NO utilice el Motor...................................120V, 50/60 Hz ventilador en una ventana, ya que la lluvia podria crear un peligro Tamano de paletas ............. 6" ( 15.2 cm) electrico. Cordon electrico .................6 pies (1.8 m), 18/3 ADVERTENCIA: PARA REDUCIR EL RIESGO DE INCENDIOS O Ve...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría