|
Resumen del manual
Please call Frigidaire at 1.800.944.9044 to order this kit. *2: “Dimension A” in the chart represents the height from cook top to where the bottom screw mounting holes would be located. *3: Recommended mounting height *4: Recirculation Kit cannot be installed. Step 2: • Install the range hood (1) either with wood screws or long screws, depending on the wall type: Wall type Required screws Wood 4 wood screws (11) Brick/Concrete 4 long screws (8) • Insert 2 screws (8 or 11) in the top location, but do not fully insert the screws (fig. ). Mount the range hood (1) to the wall and tighten the screws. Insert and tighten the 2 remaining screws on the bottom location of the range hood (fig. / ). • Attach the collar (5) to the range hood (1). Secure with 2 short screws (8) (fig. ). 0.08” 0.08” fig. fig. fig. fig. NOTE Sometimes, sponge tape covers the holes. If the holes are located behind the sponge tape, simply insert the screw through the sponge tape. Step 3: • Mount upper and lower brackets (3, 4) on the wall. Secure with the remaining 4 sets of long screws (8). The notches of the lower bracket should be facing up towards the ceiling (fig. ). • Attach the exhaust duct. In the example below a round metal duct furnace pipe has been used. The airtight connection of the exhaust duct should then be improved with a duct tape. This ensures tight fit and that no grease vapors will escape from the duct (fig. ). fig. fig. 9 GB Electrical connections DANGER Danger of electric shock! All fittings must be installed by a competent person in accordance with current wiring regulations and local building regulations. If in doubt, consult a qualified electrician. IMPORTANT Always switch off the electricity supply at the mains during installation, cleaning and maintenance. We recommend that the fuse is withdrawn or circuit breaker switched off at the distribution board while work is in progress. Step 4: • Loosen the 2 short screws from the junction box (fig. ). ffigig.. • Connect the incoming positive, neutral and ground cables to the respective terminals. The ground cable is already pre-assembled onto the junction box to provide grounding (fig. ). fig. L (live) = Black (ground) = Green N (neutral) = White L N • Mount the junction box onto the range hood using 2 short screws (13) (fig. ). fig. Step 5: • Insert the upper chimney (2) into the lower chimney (3) from top to bottom (fig. ). • Mount lower chimney (2) on the range hood (1). • Fit the tab, which is bend by 90 degrees, into the lower bracket notch and mount to the lower bracket (4) (fig. / ). • Fix it with 2 screws (12) (fig. ). fig. fig. fig. • Pull the upper chimney (2) to the upward position to match the screw hole of the upper bracket. Mount to the upper bracket (3) with 2 side screws (10) (fig. ). Installing the hood 10 Installing the hood fig.fig. CAUTION Danger of injury. The chimney skirts may have some sharp edges. Exhaust operation • During exhaust operation, the range hood removes air from a room. If ...
Otros modelos de este manual:Los aficionados - FHWC3655LSA (1.59 mb)
Los aficionados - FHWC3055LSA (1.59 mb)
Los aficionados - FHWC3055LSA (1.59 mb)
Los aficionados - FHWC3055LSA (1.59 mb)