Iniciar sesión:
Votos - 4, Puntuación media: 3.8 ( )

Manual de usuario Venmar, modelo 700 cfm

Fabricar: Venmar
Tamaño del archivo: 1.64 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


VK0003F 12.00"[305] Couvercle duboitier PTSVRC 1200i NOYAU POLYavec module recirc. VRC 1200i NOYAU ALUavec module recirc. LBS247 Kg112 PTSTOTAL LBS269 122Kg TOTAL NOTES: Dimensions in [ ] are in millimeters Appendix B Continued Unit Dimensions B-5: 700 cfm Page 14 HRV700iLBS Kg 32.74 14.85 68.46 31.05 35.20 15.97 73.60 33.38 210.00 ABCDTOTAL 95.25PTS 14 gauge wire nutCondensate drain fitting (2x) AB 3/4" mpt CONNECTION TABLECONNECTION SIZES 10.000"[254] Center of gravityDirection of airflow1.875"[48] EXHAUST AIROPENINGSUPPLY AIROPENING20.750"[527] 8.000"[203]10.750"[273]7.500"[191] 10.605"[269] 12.104"[307]2.157"[55] 2.000"[51] 37.000"[940] 24.736"[628]31.080"[789] 51.000"47.000"[1194] 8.000"[203] DEFROST AIROPENING EXHAUSTAIR OUTDOOR AIROUTDOOR AIROPENINGRETURN AIROPENING RETURN AIRCONDENSATE DRAIN SUPPLYAIR 3.625"[92] 2.000"[51] 14.000"[356]1.875"[48] 3.750"[95] 40.500"[1029] 8.000"[203]12.250"[311]8.000"[203] 15.250"[387] B A 2.000"[51] Line Voltage InA minimum of 12.00" [305] clearance from anyobstruction is required for power hook-up, lowvoltage remote connection, and control panel access.Low VoltageTerminal Strips 8.000" [203] 22.500"[572] A B C D TOP [1295] LEFT SIDE FRONT RIGHT SIDE A minimum of 21.00" [533] clearance from any obstruction is required for removal of heat recovery cores, fans, etc. The access door can be removed from cabinet with only 2.00" [51] of clearance. 21.000" VK0002A ACCESS DOOR [533] HEAT RECOVERY CORE Appendix C Flow Station Positions 600 cfm and 1200 cfm Flow Measuring Station (FMS) Balancing Damper Canvas Vibration Isolator Min. 12" (305mm) Min. 30" (762mm) Reverse Door Option Exhaust Air From Building Fresh Air From Outside Min. 8" (203mm) (Optional) Canvas Vibration Isolator Min. 12" (305mm) VP0001A 700 cfm Min.12" (304mm) Flow Measuring Station (FMS) Balancing Damper (not supplied) Canvas Vibration Isolator Dry Contacts Min. 12" (304mm) Min. 30" (762mm) VP0002A Page 15 Appendix D Drain Connections 600 cfm and 1200 cfm Note: Plastic Hose Plastic Drain FittingsAll hose, pipe & couplers to be 3/4"NPT supplied by others Coupler To Drain Copper or Plastic Pipe Water Trap TD i 700 cfm All hose, pipe, and couplers to be supplied by others. Plastic Hose Water Trap 3/4" NPT To Drain Copper or Plastic Pipe Plastic Drain Fitting Note: Coupler To Drain Page 16 Appendix E Terminal Control Diagrams E-1: Terminal Label E-2: Wall Control Connection A low voltage remote control wiring interface is provided on the unit. The connections for the low voltage remote wiring are located on two terminals adjacent to the exhaust fan outlet (or adjacent to the supply fan outlet on the 700 cfm unit). All field installed wiring must be low voltage class II. Remote Wall Control Optional wall control requires a 4 wire LVT-24 gauge (or equivalent). This remote wall control runs on 12 VDC. Low Voltage Controls All other terminals are dry contacts. Low Voltage terminal control consists of the following: Wall Control 4 wire LVT 24 gauge minimum Occupied (Night set back) Timer/Sensor 24 VAC, needs dry contact LOW - COM - HIGH Remote fan switching requires a single pole, double throw switch (SPDT) Fan Interlock Relay Output (FF) Dry contact closes on ventilation or defrost. Used to control external fan. WALL CONTROL CLASS 2 VOLTAGE Black OCCUPIED TIMER/ SENSOR F F LOW COMMON HIGH Red Green Yellow NOTE: Connections are all dry contacts except wall control and 24VAC power supply. Use of 24VAC circuit requires isolating contacts (ex. thermostat) to prevent interconnection of Class 2 outputs. Four types of remote wall controls are available: 1. Slide Switch Wall Control with fan switch and dehumidistat control 2. Push Button Electronic Wall Control with fan mode selection, dehumidistat control and maintenance indicator 3. Pollutant Wall Control with fan mode selection and air pollutant sensor/control 4. Pool Wall Control with fan mode selection, dehumidistat control and high speed recirculation mode. The remote wall controls work with the microprocessor electronic control within the unit to control ventilation sequences. Each wall control has different features and require 4-wire connection to the unit as shown below. Without the wall control, fans can be operated with a remote fan switch as shown in Appendix E-4. NOTE: An occupied timer or sensor device cannot be used with the push button pool or pollutant wall controls. Wall Control JUMPER WALL CONTROL CLASS 2 VOLTAGE Black OCCUPIED TIMER/ SENSOR F F LOW COMMON HIGH Red Green Yellow NOTE: Connections are all dry contacts except wall control and 24VAC power supply. Use of 24VAC circuit requires isolating contacts (ex. thermostat) to prevent interconnection of Class 2 outputs. VE0006A VE0002A Page 17 Appendix E Continued Terminal Control Diagrams E-3: Occupied Timer/Sensor Connection Occupancy control is achieved by connection to the terminal interface shown below. These terminals require a dry contact which could be provided by a number of types of controls s...

Otros modelos de este manual:
Los aficionados - 1200 cfm (1.64 mb)
Los aficionados - 600 cfm (1.64 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría