|
Resumen del manual
1 - --Energy Recovery Ventilators NOTE TO EQUIPMENT OWNER: For your convenience, please record the model and serial numbers of your new equipment in the spaces provided. This information, along with the installation data and dealer contact information, will be helpful should your system require maintenance or service. ENERGY RECOVERY VENTILATOR INSTALLATION INFORMATION: Model # _____________________________________ Date Installed ________________________________ Serial # ______________________________________ DEALERSHIP CONTACT INFORMATION: Company Name_______________________________ ACCESSORIES (List type and model #) Address______________________________________ _____________________________________________ Phone Number _______________________________ NOTE TO INSTALLER: This manual must be left with the equipment owner. 1 INTERMITTENTMAXMINAIR EXCHANGE OFF LOW INTERMITTENT ON % RELATIVE HUM. EXT. TEMP. 21 C+ / 70 F+ 10 C / 50 F 0 C / 32 F 60% 55% 45% INTERMITTENTMAXMINAIR EXCHANGE OFF LOW INTERMITTENT ON % RELATIVE HUM. EXT. TEMP. 21 C+ / 70 F+ 10 C / 50 F 0 C / 32 F 60% 55% 45% OneTouch Control Latent Control A05367 Fig. 2 - --Controls SAFETY CONSIDERATIONS Recognize safety information. This is the safety- --alert symbol When you seethissymbolon theunitand in instructions ormanuals, be alert to the potential for personal injury. Understand these signal words; DANGER, WARNING, and CAUTION. These words are used with the safety- --alert symbol. DANGER identifies the most serious hazards which will result in severe personal injury or death. WARNING signifies hazards which could result in personal injury or death. CAUTION is used to identify unsafe practices which may result in minor personal injury or product and property damage. NOTE is used to highlight suggestions which will result in enhanced installation, reliability, or operation. ! OPERATING YOUR ENERGY RECOVERY VENTILATOR (ERV) WITH ONETOUCH CONTROL Press “PUSH” until the desired ventilation operation is selected. There are three selections: High, Low, Intermittent. The power indicator light indicates which mode has been selected. High: This mode is recommended for the removal of excess pollutants and humidity. The ventilator will operate at its maximum speed continuously. The power indicator light will be lit red when this mode is selected. Low: This mode is recommended for normal daily operation. The ventilator will operate at its minimum speed continuously. The power indicator light will be lit yellow when this mode is selected. Intermittent: This mode is recommended when the inside air is too dry in the heating season or too humid in the cooling season. The ventilator will operate at its minimum speed for 20 minutes per hour and be off for 40 minutes per hour. The power indicator light will be lit green when this mode is selected. Off: To turn the ventilator off, press “Push” until the power indicator light is turned off. OPERATING YOUR ENERGY RECOVERY VENTILATOR (ERV) WITH BASIC, STAN...
Otros modelos de este manual:Los aficionados - ERVCCLHU (135.93 kb)
Los aficionados - ERVCCSVA (135.93 kb)