After it has reached a height of 180 mm from the cooketop, press OFF, to stop the extraction then the Timer and after 2 sec. the OFF button. The downdraft will carry out the calibration of its aspiration panel rising and retracting for some centim- 18 eters. During this phase, the buttons on the pushbutton control panel blink. At the end of the calibration, the aspiration panel get back to the previous position and the button end to blink. Wait until the aspiration panel stops moving before re-activating the extraction. UTILISATION This product is intended to extract fumes, fats, and steam from cooking. It is designed to work in both suction-ing mode, with outside evacuation, and filtering mode. VERSION EVACUATION exterieure The hood is equipped with an air outlet to convey smoke outwards (the flue pipe and fixing flange are not supplied). Check valve blockage Warning: Before connecting the air exhaust hose, make sure that the check valves are free to turn over freely. For hoods with outside air exhaust, fit a check valve to prevent wind and returning air from entering. Filtering mode In case fumes and vapour cannot be evacuated outside, the appliance can be used in the filtering mode. Carbon filters are required for this type of hood. Air recycled through the charcoal filters is reintroduced into the kitchen, thanks to a duct conveying the air on one side of the cabinet (Fig. 14 bis). Installation must conform to the regulations in force regarding the ventilation of enclosed environments. In particular, discharged air must not be channelled into a conduit used for exhaust discharge or discharge from devices that operate with gas or other combustible materials. The use of unused conduits is not permissible without the approval of a qualified technician. - CREASE FILTER REMOVAL - MOUNTING THE CARBON FILTER The removal and fitting of the grease and carbon filters need to be carried out with the downdraft in the open position. To open the downdraft, push the ON/1 key. Then remove the front panel, pushing the upper part of each side at the same time. The panel will rotate forwards to make it possible to access the grease filters (Fig. 16). Remove the grease filters to access the carbon filters (Fig. 17). /The replacement of the charcoal filters has to be carried out accordingly to the effective use of the Downdraft, and in any case at least once every 6 months. After having replaced the filters, reinstall the front stainless steel panel, otherwise the Downdraft is not enabled to function. 19 - ELECTRIAL HOOK UP OF THE HOOD WARNING: Place the metal box containing the electronic components at a distance of no less than 65 cm from gas-operated cook tops or in any case, 65 cm from the extraction point of the hood. RECOMMENDATION: We recommend installing the metal box containing the electronic components at least 10 cm above floor level and at a suitable distance from all heat sources (e.g. oven sides or cook top). This appliance is fitted with an H05 VVF 3 conductor, 0.75 mm2 (neutral, phase, and ground) power cable. This can be hooked up to a 220 - 240 V mono-phase electrical network by way of a CEI 60083 regulation power socket that must remain accessible after installation, in conformity to installation regulations. We decline all responsibility in case of accident caused by a lack of ground connection or incorrect ground connection. The appliance must be fed through a differential protection device (RCD), with a nominal residual current not exceeding 30mA. If the power cable is damaged, call the after-sales service to avoid any risk. The connection of Downdraft to the electric network must be carried out by qualified and skilled technicians. The cooker hood can only be connected to one electric network, properly arranged and installed. The electric system must comply with the VDE0100 standard. Attention If the hood presents some form of anomaly, unplug the appliance or remove the fuse corresponding to the appliance’s power line. If the appliance has no plug or if the plug is not easily accessible, then a device needs to be fitted to cut it off from the mains electricity; this device must have an opening distance between contacts on all poles of at least 3 mm. ELECTRIAL HOOK UP This appliance conforms to the European Directives 2006/95/EC (Low Voltage Directive) and 2004/108/EC (Electromagnetic Compatibility). When you install the appliance and carry out maintenance, it must be unplugged from the power source or the fuses must be disengaged or removed. Electrical hook up must be carried out before the appliance is installed in the cabinet. Check that: - the power source is sufficient, - power cords are in good condition, - The diameter of the cables conforms to installation regulations. 20 3/ HOW THE HOOD WORKS EN Model S.DD2 STANDARD VERSION (Fig. 22) A: Extraction panel down/OFF switch This serves to close the extraction panel either completely or in intermediate positi...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría