Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario GE, modelo GE Monogram ZVB30SN

Fabricar: GE
Tamaño del archivo: 315.97 kb
Nombre del archivo:

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


Use this kit when the blower and motor assembly will be located outside of the cabinet, such as below the cabinet floor. The assembly will fit between 16" floor joists. JXBC67 Outdoor cover accessory for remote installation of the blower/motor assembly on an outside wall. Ductwork Prepare the ductwork to vent to the outdoors. • Plan the shortest and straightest route for venting exhaust to the outdoors. • The maximum permissible length for the duct run is 150 feet. • Use metal ductwork only. • The downdraft blower system is designed to use 3-1/4" x 10" duct. It can be transitioned to 6" round. • Install a wall cap or roof cap with damper at the exterior opening. Order the wall cap and any transition needed in advance. 605Dia160Cover PanelBase SinkEndPanelCountertop Overhang per CooktopClearances Must be Maintained Island or peninsula installation Use an extra-deep countertop. The countertop overhang at the front can be adjusted to meet setback to cutout requirements. Venting Options The downdraft vent is shipped with the discharge outlet pointing straight down and can be changed to a left- or right-side discharge. For even more flexibility, the entire blower and mounting plate can be adjusted 3-1/2" to the left or right sides. Electrical and Gas Locations Plan the placement of the electrical outlet and gas (if used) carefully. Gas or electrical outlets cannot be located on the back wall of the cabinet because they may interfere with the downdraft plenum. • Install a standard electrical outlet within reach of the vent’s two-foot-long power cord. Locate the outlet inside the cabinet on the right side wall. • If the vent is installed in combination with a Monogram® gas cooktop, it may operate from the same 120V standard duplex outlet. • If the vent is installed in combination with a Monogram electric cooktop, the vent must operate from a separate 120V outlet. 34" for 36" Models28-1/2" for 30" Models29-1/2" ElectricalOutlet12" AboveCabinet FloorDo Not Locate Gas or ElectricalConnections Within Shaded Area682Dia47 Features and Benefits • Raises To 8-1/2” Over Cooktop Surface When You Cook, Then Retracts When Not in Use • 500-CFM Performance Helps Keep Your Kitchen Free of Fumes and Excess Heat • Remote-Mounted Control Provides Design Flexibility • Variable-Speed Blower with Electronic Controls Complements Most Monogram Cooktops • Removable Grease Filters Trap Airborne Grease Particles • Optional Remote Blower Capabilities • Stainless Steel Vent Body Offers a Smooth and Polished Appearance • Model ZVB30SNSS - Stainless steel (shown) • Model ZVB30BNBB - Black on black ZVB30SNSS ...

Otros modelos de este manual:
Los aficionados - GE Monogram ZVB30BN (315.97 kb)
Los aficionados - GE Monogram ZVB30BNBB (315.97 kb)
Los aficionados - GE Monogram ZVB30SNSS (315.97 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría