Iniciar sesión:
Votos - , Puntuación media: ( )

Manual de usuario Haier, modelo 3000

Fabricar: Haier
Tamaño del archivo: 4.32 mb
Nombre del archivo: hhv3330_manual.pdf

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


Securely tighten cable clamp onto house wiring. KEYHOLE (4) MOUNTING SCREW Green Ground Screw 10 GREEN GROUND SCREW DUCT TAPE PAR20, 50W MAX. HALOGEN BULB -or- PAR20, 8W MAX. LED BULB KEYHOLE (4) MOUNTING SCREW (4) ! English GREEN GROUND SCREW DUCT TAPE PAR20, 50W MAX. HALOGEN BULB -or- PAR20, 8W MAX. LED BULB KEYHOLE (4) MOUNTING SCREW (4) ! Installing Hood GREEN GROUND SCREW DUCT TAPE KEYHOLE (4) MOUNTING SCREW (4) ! 1. Hang hood from (4) Mounting Screws (from parts bag). Be sure to place a washer (included) onto each screw before driving in the screw. Slide hood towards wall until mounting screws are engaged in narrow end of (4) Keyholes. Tighten mounting screws securely. 2. Replace bottom cover. 3. Connect ductwork to hood. Use Duct Tape to make joints secure and air tight. 4. If you have a 4000 series model, install (2) dimmable PAR 20, 8W LED lights. Please note that the LED lights must be dimmable in order to adjust light settings. If you have a 3000 series model, install (2) PAR 20, 50W halogen lights. CAUTION : Bulbs may be hot! Refer to bulb packaging for further information. 5. Replace filters*, turn on power at service panel, and test range hood for proper operation. * If hood is to be installed Non-Ducted, install either the HEPA or charcoal filters (whichever are included with your model) in place of the aluminum filters that were removed earlier. The HEPA or charcoal filters can be found in a plastic bag labeled as such included with your unit. For Ducted installations, reinstall the aluminum filters. 11 English Operating the Range Hood 4000 series models (For 3000 series models, see next section.) Light Settings Press the “on/off” button to turn on lights. Once lights are turned on, there are three light settings from which to select. Use “–“ or “+” buttons to set lights to desired brightness level. Press the “on/off” button a second time will turn off lights. Fan Speed Settings Your new Haier range hood comes equipped with 3 different fan speeds: “low”, “med”, or “high”. To turn on the fan, simply press the button corresponding to the desired fan speed. Each fan speed button has a light above the button that will illuminate to indicate the fan speed that has been selected. To turn off the fan, press the button corresponding to the speed the fan is currently running (press the button under the light that is illuminated). Auto-off function Pressing “auto-off” while the fan is on activates the auto-off function. You can select 15 or 30 minutes as the auto-off time. Pressing “auto-off” button one time will illuminate the left-most indicator light above the button to show that the 15 minute auto-off time has been selected. Pressing “auto-off” again selects the 30 minute auto-off time and will turn on the second indicator light. A third press cancels the auto-off function. Hold 3 secs to reset Hold 3 secs to reset 12 English Heat Sensor This unit is equipped with a Heat Sensor that automatically turns off the fan if a certain temperature is reached from cooktop heat. The fan will go up to high speed until the temperature comes back down to a normal temperature level. Once the normal temperature has been reached, the unit will return to the previous setting before the heat sensor was activated. Filter change signal reset If the filter change signal is on, press and hold “filter” for 3 seconds to reset once the filter has been changed. Hold 3 secs to reset 13 English o low high o low med lter high 3000 series models (For 4000 series models, see previous section.) Light Settings There are 2 light settings available, “low” and “high” To turn on, simply position the slider to the desired brightness level. To turn off the light, move slider back to the “off” position. Fan Speed Settings Your new Haier range hood comes equipped with 3 different fan speeds: “low”, “med”, or “high”. To turn on the fan, simply position the slider below the desired fan speed. To turn off the fan, move slider back to the “off” position. Filter Change Signal Reset If the filter change signal is on, press “filter” to reset once the filter has been changed. Hold 3 secs to reset 14 English Use and Care Aluminum Filter For highest efficiency, this filter should be removed and cleaned periodically. Soak the filter in hot water and mild soap or detergent. Rinse thoroughly and repeat if necessary. Heavy grease buildup may not be cleaned easily, thus the filter may need to be replaced. Hint: It is recommended to clean the aluminum filter ever time the filter change signal is activated. HEPA/Charcoal Filter This filter should be changed when the filter change signal is activated. This filter cannot be cleaned and must be replaced when it becomes saturated. Contact Haier at 1-877-337-3639 or check with your local retailer or dealer to purchase replacement filters. Please note that if power is lost on 3000 series, the filter change signal timer also resets. If this happens, you may need to replace the filter before the change signal is ...

Otros modelos de este manual:
Los aficionados - 4000 (4.32 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría