Manual de usuario Faber, modelo 500 CFM

Fabricar: Faber
Tamaño del archivo: 542.71 kb
Nombre del archivo:
Idioma del manual:enfr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


For best results, use no more than three 90° elbows. Make sure that there is a minimum of 24" of straight duct between elbows if more than one is used. Do not install two elbows together. If you must elbow right away, do it as far away from the hood's exhaust opening as possible. 45. Elbow 3.0 feet 90. Elbow 5.0 feet 90. Flat Elbow 12.0 feet Wall Cap0.0 feet FIGURE 2 9 Feet Straight Duct 9.0 feet 2 - 90. Elbows 10.0 feet Wall Cap 0.0 feet Total System 19.0 feet FIGURE 3 Version 03/08- Page 5 INSTALLATION DIMENSIONS PREPARE THE WALPREPARE THE WALL The Synthesis chimneys are adjustable and designed to meet varying ceiling heights as indicated in FIGURE 4. The chimneys can be adjusted for ceilings between 7' 8 1/2" and 9' 5 7/8" depending on the distance between the bottom of the hood and the cooktop (distance x in FIGURE 4). upper 1” min chimney16 3/8” max min & max ceiling height examples x = 24" x = 26" x = 28" x = 30" 22” lower chimney min 7' 8 1/2" max 8' 11 7/8" min 7' 10 1/2" max 9' 1 7/8" min 8' 1/2" max 9' 3 7/8" min 8' 2 1/2" max 9' 5 7/8" For shorter ceilings, have the chimney 9 1/2” canopy cover(s) cut at a sheet 19 1/4” metal shop. For higher ceiling installations, the x = distance from hood to cooktop High Ceiling Chimney (varies depending on installation) x min -24”, suggested max -30” Kit includes a new 40” also consult cooktop upper chimney which manufacturer's recommendation would replace the 16 3/8” upper chimney thatcame with the hood. 36” cabinet base FIGURE 4 FIGURE 5 1. Disconnect and move freestanding range from cabinet opening to provide easier access to upper cabinet and rearwall. Put a thick, protective covering over cooktop, set-inrange or countertop to protect from damage or dirt. 2. Determine and clearly mark with a pencil the center lineon the wall where the rangehood will be installed. 3. The canopy attaches to the wall by two mounting brackets(1 in FIGURE 5). The canopy of the rangehood hangs on the two brackets which must be mounted with the flanges on the top of the bracket and pointing away from the wall. Before installing the brackets, the adjustment screws must be installed into the bottom of the bracket. These two screws are provided in the hardware package and have hexagon heads with a slot for a flat blade screwdriver. The dimensions illustrate mounting the canopy 24" above the cooking surface. If a Backsplash is to be used with this rangehood, it must beinstalledbeforetherangehood. Installationinstructions for the Backsplash are supplied in its box. The height of the Backsplash will determine the bottom edge of the canopy. 4. The chimney mounts by two brackets (2 in FIGURE 5). Note the position of the brackets. The top bracket shouldbe installed about 1/8" away from the ceiling. The bottombracket must be installed at the bottom point of the upperchimney sleeve. Determine the proper location for each bracket and installthe brackets on the wall. MAKE SURE THAT THE BRACKETS ARE SECURELY FASTENED TO THE WALL. 5. Determineandmakeallnecessarycutsinthewallforthe ductwork. Install the ductwork before the rangehood. 6. Determine the proper location for the Power Supply Cable (FIGURE 6). Use a 1 1/4" Drill Bit to make thishole. Run the Power Supply Cable. Use caulking to seal around the hole. DO NOT turn on the power until installation is complete. 30 MODELS 36 MODELS FIGURE 6 Version 03/08- Page 6 INSTALL THE RANGEHOOD FOR DUCTLESS INSTALLATIONFOR DUCTLESS INSTALLATIONS 1. Remove the unit from the carton and place on a flat surface for assembly. Cover the surface to prevent accidental damage. Remove all parts including the mounting hardware before discarding the carton. 2. Remove the grease filters from the unit and set aside. The grease filters are removed by pressing the handle in front of the filter (FIGURE 7). When replacing, make sure that the filters are properly positioned with the handles in front and visible. FIGURE 7 3. Removethecoverfromthefieldwiringcompartment. Remove thewiringelectricalknockoutusingaflat-bladescrewdriver. Feed the Power Supply Cable through the electrical knockout. 4. Hang the canopy on the brackets (1 in FIGURE 8). There are two rectangular holes on the rear of the canpoy. The brackets pass through these holes and the canopy hangs from the flanges on the brackets. Due to the weight of the canopy, two people should lift it to avoid injuries. Make sure that the canopy is secure on the brackets before releasing. 5. Level the canopy. The height and level of the canopy can be adjusted by rotating the adjustment screws (W in FIGURE 8) on each side of the blower inside the rangehood. FIGURE 8 6. Connect the Power Supply Cable to the rangehood. Attach the White lead of the power supply to the White lead of the rangehood with a twist-on type wire connector. Attach the Black lead of the power supply to the Black lead of the rangehood with a twist-on type wire connector. Connect the Green (Green and Yellow) ground wire under the Green grounding screw. 7. Re...

Otros modelos de este manual:
Los aficionados - 280 CFM (542.71 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría