Fabricar: Emerson
Tamaño del archivo: 203.29 kb
Nombre del archivo: 84a63e93-63f1-4cee-8335-9e077d7b532f.pdf
|
Resumen del manual
Figure 4 NOTE: If you are using an Emerson Light Fixture with your fan, see Light Fixture Owner’s Manual for wiring. 2. Securely connect the fan motor white wire to the supply white (neutral) wire using wire connector supplied (Figure 4). Securely connect the fan motor black wire and blue wire to the supply black (hot) wire using wire connector supplied (Figure 4). After connections have been made, turn leads upward and carefully push leads into the outlet box, with the white and green leads on one side of the outlet box and the black and blue leads on the other side of the outlet box. WARNING ! Check to see that all connections are tight, including ground, and that no bare wire is visible at the wire connectors, except for the ground wire. Do not operate fan until blades are in place. Noise and fan damage could result. 3. Screw the two 1-1/4” threaded studs (provided) into the tapped holes in the hanger bracket. 4. Lift the ceiling cover up to the threaded studs and turn until studs protrude through the holes in the 5. Secure the ceiling cover in place by sliding lock- washers over the threaded studs and installing the two knurled knobs (supplied). (Figure 5.) Tighten the knurled knobs securely until the ceiling cover fits snugly against the ceiling and the hole in the ceiling cover is clear of the downrod. Your fan is now wired to be turned on and off from the fan switch. KNURLED KNOB CEILING COVER LOCKWASHERS (2) 1-1/4" THREADED STUD Figure 5 ! WARNING To avoid possible fire or shock, make sure that the electrical wires are completely inside the outlet box and not pinched between the ceiling cover and the ceiling. 6. Slip the switch pull chain through the hole in the snapping the coupling (supplied) onto the end of the chain. Using Your Ceiling Fan 1. Restore electrical power to the outlet box by turning the electricity on at the main fuse box. 2. Check the operation of the fan by gently pulling on the pull chain switch. 3. If airflow is desired in opposite direction, turn your fan off and wait for the blades to stop turning, then slide the reversing switch to opposite position, and turn fan on again. The fan blades will turn in the opposite direction and reverse the airflow. Your fan model is equipped with a 4-position pull chain switch. The operating sequence is as follows: THREE-SPEED 1st Pull—HIGH 2nd Pull—Medium 3rd Pull—Low 4th Pull—OFF pendant (supplied), then secure the pendant by SPEEDCONTROLREVERSIBLESWITCH SWITCH ceiling cover (Figure 5). 8 Attaching Light Kit WARNING ! To avoid possible electrical shock, be sure electricity is turned off at the main fuse box before wiring. To install an accessory light kit, remove the three screws securing the switch cup assembly to the fan, remove the switch cup assembly, and disconnect the connector. Remove the screw plug from the bottom of the switch cup and install the light kit in accordance with the light kit Owner's Manual. Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Periodic cleaning of your new ceiling fan is the only maintenance that is needed. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish. WARNING ! Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the possibility of an electrical shock. Accessories 1. Ceiling Fan Light Kits (see store or catalog). 2. Ceiling Fan/Light Controls (see store or catalog). 3. Downrod Extension Kits (see store or catalog). WARNING ! WARNING ! The use of any other control not specifically approved for this fan could result in fire, shock and personal injury. This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson Company. Substitution of parts or accessories not designated for use with this product by Emerson Company could result in personal injury or property damage. 9 Repair Parts 1 2 16 13 14 18 17 18 15 19 8 24 5 4 23 12 11 25 26 30 28 20 29 21 22 9 10 7 Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS 3 WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • NAME OF ITEM • MODEL NUMBER 6 • THE PART NUMBER • THE PART DESCRIPTION For repair parts, phone 1-800-654-3545. 27 10 11 Repair Parts List Ref.No. Description 52” “ APOLLO” Series ModelsCF3900WW01 CF3900AB01 CF3900PB01 CF3900WPB01 CF3900OB01 CF3900HTW01 CF3900BS01 CF3900BQ01 CF3900TG01 CF3900AW01 CF3900CK01 123 Hanger Pack,containing:Bracket, Hanger (1)Hanger Ball Assembly (1)Downrod (1) 761655——— 761...
Otros modelos de este manual:Los aficionados - CF3900AB01 (203.29 kb)
Los aficionados - CF3900AW01 (203.29 kb)
Los aficionados - CF3900BS01 (203.29 kb)
Los aficionados - CF3900CK01 (203.29 kb)