Resumen del manual


Trouble Shooting TROUBLE PROBABLE CAUSE SUGGESTED REMEDY 1. Fan will not start. 1. Fuse or circuit breaker blown. 2. Loose power line connections to the fan, or loose switch wire connections in the switch housing. 1. Check main and branch circuit fuses or circuit breakers. WARNING: Make sure main power is turned off. 2. Check line wire connections to fan and switch wire connections in the switch housing. ! 2. Fan sounds noisy. 1. Blades not attached to fan. 2. Loose screws in motor housing. 3. Screws securing fan blade flanges to motor hub are loose. 4. Wire connectors inside switch housing rattling. 5. Screws holding blades to flanges are loose. 1. Attach blades to fan before operating. 2. Check to make sure all screws in motor housing are snug (not over-tight). 3. Check to make sure the screws which attach the fan flanges to the motor hub are tight. WARNING: Make sure main power is turned off. 4. Check to make sure wire connectors in switch housing are not rattling against each other or against the interior wall of the switch housing. 5. Tighten screws securely. ! 3. Fan wobbles 1. Setscrew in motor coupling is loose. 1. Raise motor cover and tighten setscrew excessively. 2. Setscrew in hanger ball/downrod assembly is loose. 3. Screws securing fan blade flanges to motor hub are loose. 4. Fan blade flanges not seated properly. 5. Hanger bracket and/or ceiling outlet box is not securely fastened. 6. Fan blades out of balance. securely. 2. Tighten the setscrew in the hanger ball/ downrod assembly. 3. Check to be sure screws which attach the fan blade flanges to the motor hub are tight. 4. Check to be sure the fan blade flanges seat firmly and uniformly to the surface of the motor hub. If flanges are seated incorrectly, loosen the flange screws and retighten according to step 15 or 17 in Sections “A” or “B” “Assembly Instructions”. 5. Tighten the hanger bracket screws to the outlet box, and/or secure outlet box. 6. Interchanging an adjacent (side-by-side) blade pair can redistribute the weight and result in smoother operation. Or use supplied balancing kit to balance blades. Maintenance IMPORTANT CARE INSTRUCTIONS for your Ceiling Fan Do not use water when cleaning your ceiling fan. It could damage the motor or the blades and create the WARNING ! Periodic cleaning of your new ceiling fan is the only maintenance that is needed. possibility of an electrical shock. When cleaning, use only a soft brush or lint free cloth to avoid scratching the finish. Abrasive cleaning agents are not required and should be avoided to prevent damage to finish. 13 Repair Parts WARNING ! 1 2 18 3 The use of any other control not specifically approved for this fan could result in fire, shock and personal injury. 15 20 4 26 9 8 30 19 20 29 27 22 17 5 23 24 7 12 1128 10 25 6 21 16 19 WARNING ! This product is designed to use only those parts supplied with this product and/or any accessories designated specifically for use with this product by Emerson. Substitution of parts or accessories not designated for use with this product by Emerson could result in personal injury or property damage. ACCESSORIES 1. Ceiling Fan Light Kits (see store or catalog). 2. Ceiling Fan/Light Controls (see store or catalog). 3. Downrod Extension Kits (see store or catalog). Before discarding packaging material, be certain all parts have been removed. HOW TO ORDER REPAIR PARTS WHEN ORDERING REPAIR PARTS, ALWAYS GIVE THE FOLLOWING INFORMATION: • NAME OF ITEM • MODEL NUMBER • THE PART NUMBER • THE PART DESCRIPTION For repair parts, phone 1-800-654-3545. 14 13 14 Repair Parts List Ref. No. Description Botanica Models CF2500OB01 CF2500S01 CF2500HTW01 CF2500TG01 1 2 3 Hanger Pack, containing: Bracket, Hanger (1) Hanger Ball Assembly (1) Downrod (1) 761655-9 — — — 761655-16 — — — 761655-12 — — — 761655-13 — — — 4 Cover, Ceiling 761620-9 761620-24 761620-12 761620-23 5 Hub, Rubber 760601 760601 760601 760601 6 Blade Assembly (Full set for one fan) * * * * 7 Flange Set (Full set for one fan) 761885 761885-1 761885-2 761885-3 8 Switch Housing Assembly 761902 761902 761902-1 761902 9 Cover, Motor 761621-9 761621-16 761621-12 761621-13 10 Motor 762304 762304 762304 762304 11 12 13 14 15 16 17 18 19 20 21 22 23 24 25 26 Parts Bag, containing: Pin, Clevis (1) Clip, Hairpin (1) Coupling (1) Pendant (1) Wire Connector (3) Wrench, Hex, 3/16” Wrench, Hex, 5/32” Stud, Threaded 1-1/4” (2) Lockwasher (4) Knob, Knurled (4) Screw, 10-32 x 5/8" (11) Screw, Flathead, 8-32 x 3/8" (4) Screw, 10-24 x 3/8" (16) Washer, Flat (16) Setscrew, 7/16-18 x 1/4" (1) Stud, Threaded, 1” (2) 761907-1 — — — — — — — — — — — — — — — — 761907-1 — — — — — — — — — — — — — — — — 761907 — — — — — — — — — — — — — — — — 761907-1 — — — — — — — — — — — — — — — — 27 Cover, Switch Housing Assembly 761889 761889-1 761889-2 761889-3 28 Aux. Capacitor 761453 761453 761453 761453 29 Screw, #8 Washerhead, 8-32 x 3/8” (4) — — — — 30 Uplight Lead Assembly 761790 761790 761790 761790 — Owner's Manual BP7220-3 BP7220-3...

Otros modelos de este manual:
Los aficionados - CF2500OB01 (317.97 kb)
Los aficionados - CF2500HTW01 (317.97 kb)
Los aficionados - CF2500S01 (317.97 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría