|
Resumen del manual
For vented installations, go to Step 11. For non-vented installations, go to “Make electrical connection”. up to 1” (2.5 cm) top/back edge pivot side-to-side adjustment pivot damper/vent connector VERTICAL vent position HORIZONTAL vent position 11. Rectangular vent only: Attach damper/vent connector over knockout opening. Make sure damper pivot is nearest to top/back edge of hood. Remove tape from damper flap. Note: For horizontal vent systems, it is recommended that the rectangular ventwork be attached to the damper/vent connector and sealed with duct tape before installing the hood. 12. Round vent only: Re-install round vent plate removed in Step 5 under “Prepare the hood” section. Install a 7" (17.8 cm) round damper (must be purchased separately). Damper flap must open freely in direction of air flow (away from range hood). Note: Damper/vent connector and round vent plate can be installed up to 1" (2.5 cm) on either side of hood center if ventwork is off- center. In extreme off-center installations, one end of the vent connector may need to be trimmed to clear the electrical strain relief. Make electrical connection WARNING Electrical Shock Hazard Disconnect power before making electrical connections. Connect ground wire to green ground screw in terminal box. Failure to do so can result in death or electrical shock. Do not turn on power until installation is complete. If not previously done, run wiring through wall or cabinets according to electrical codes and ordinances. protective cover 13. Stand hood up as shown. (Keep on protective cover to protect hood or cooking surface.) green ground screw 14. Connect the white and black wires of the power supply cable to the white and black leads in the hood with twist-on connectors. Connect the power supply ground wire to the green screw under the wiring cover. Securely tighten the strain relief. Using a U.L.-listed power supply cord-connection kit (U.S. only): Follow Power Cord Kit instructions for connecting wiring. 15. Replace wiring cover. Install the hood WARNING Excessive Weight Hazard Use two or more people to move and install range hood. Failure to do so can result in back or other injury. 1/4" (6.4 mm) 16. Remove the 4 hood mounting screws from the parts bag and install in pilot holes. Leave screw heads away from shim strips about 1/4" (6.4 cm). mounting screw keyhole slots (4) keyhole slots (4) 17. Lift range hood into final position, feeding electrical wire through wiring opening. To avoid damage, DO NOT PUSH ON FAN BLADE. Position the range hood so that the large end of the keyhole slots are over the screws. Then push the hood toward the wall so that the screws are in the neck of the slots. Tighten mounting screws to cabinet, making sure mounting screws are in narrow neck of slots. Make sure that damper blade opens and closes freely. 18. Connect ventwork to hood. Seal joints with duct tape to make them secure and air tight. center flange of cap center flange of cap 19.Remove both light socket caps. Use pliers to grip the center flanges of each cap, twist while pulling down. Discard the caps. Install (2) PAR20, 50W maximum halogen bulbs or (2) R16, 40W maximum incandescent bulbs. Bulbs must be purchased separately. 20.Replace filters. Note: Filter slot must be toward front of hood. For non-vented recirculating installations, make sure you have installed the non-vented filters on the back sides of the aluminum mesh filters. (See Step 6.) Make sure fan blade turns freely. 21.Turn power supply on and check for proper operation. To get the most efficient use from your new range hood, read the “Use and Care Information” section. Keep your Whirlpool Installation Instructions and Use and Care Guide close to range hood for easy reference. Use and Care Information WARNING — To reduce the risk of Always turn hood ON when fire or electrical shock, do not use cooking at high heat or when this fan with any solid-state speed cooking flaming foods. control device. Clean ventilating fans frequently. WARNING — TO REDUCE THE Grease should not be allowed to RISK OF FIRE, ELECTRIC accumulate on fan or filter. SHOCK, OR INJURY TO Use proper pan size. Always use PERSONS, OBSERVE THE cookware appropriate for the size FOLLOWING: of the surface element. Use this unit only in the manner WARNING — TO REDUCE THE intended by the manufacturer. If RISK OF INJURY TO PERSONS you have questions, contact the IN THE EVENT OF A RANGE manufacturer. Before servicing or TOP GREASE FIRE, OBSERVE cleaning unit, switch power off at THE FOLLOWING: service panel and lock switch SMOTHER FLAMES with a close- power off at service panel and lock fitting lid, cookie sheet, or metal service panel to prevent power tray, then turn off the burner. BE from being switched on CAREFUL TO PREVENT BURNS. accidentally. When the service If the flames do not go out disconnecting means cannot be immediately, EVACUATE AND locked, securely fasten a CALL THE FIRE DEPARTMENT. prominent warning device such as a tag to ...
Otros modelos de este manual:Los aficionados - GZ5730 (278.28 kb)