Iniciar sesión:
Votos - 2, Puntuación media: 4.5 ( )

Manual de usuario Wolf Appliance Company, modelo PW482718R

Fabricar: Wolf Appliance Company
Tamaño del archivo: 213.5 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


See warranty details at the end of this guide. WOLF PRO VENTILATION HOOD USE & CARE RECESSED CONTROLS Controls for Pro ventilation hoods and hood liners are recessed under the front edge of the hood. Refer to the illustration below. LIGHT CONTROL The left rotary switch operates the halogen lights. There are two settings, HIGH and LOW. The LOW setting can be used as a night-light. From the OFF position, turn the switch to the desired light setting, left for LOW and right for HIGH light setting. HEAT LAMP CONTROL If your hood is equipped with heat lamps, a center rotary switch will control the lamps. Each heat lamp may function independently or both lamps may be activated simultaneously from the single switch. From the OFF position, simply turn the switch to the right to activate the right heat lamp or to the left to activate the left lamp. When the switch is in the vertical position, both heat lamps will be activated. BLOWER CONTROL The right rotary switch that operates the blower is variable, allowing infinite control of the blower speed. Rotate the switch fully counterclockwise to turn the blower off. HEAT SENTRY FEATURE Heat Sentry feature turns the ventilation hood on when heat is sensed and adjusts the blower speed automatically. The Heat Sentry feature is activated when the exhaust temperature from the hood reaches 200°F (95°C) and deactivated when the exhaust temperature decreases to 186°F (85°C). At 200°F (95°C) the blower motor will automatically adjust to HIGH speed. When the sensor cools down to 186°F (85°C) it adjusts the blower back to the setting on the blower control. For example, if blower motor is in LOW speed and threshold temperature is reached, the blower will increase to HIGH speed. FILTER REMOVAL To remove the stainless steel filters, push each filter up at the angle it is placed in and rotate down. Remove the center filter first. Take out the grease cups (if applicable) placed on the bottom edge of the hood coinciding with the bottom edge of the filters. Gloves should be worn to provide the proper grip. Reinstall using the reverse procedure as shown in the illustration below. Outer filters may need to be pushed over while the center filter is reinstalled. IMPORTANT NOTE: DO NOT operate the ventilation hood without the filters. This may cause damage to the blower or other internal components of the hood. Grease Cup SIDE VIEW Filter Spring Blower ControlHeat Lamps ControlHalogen Lights Control Recessed controls Filter reinstallation—27" (686) deep wall hood shown WOLF PRO VENTILATION HOOD USE & CARE HALOGEN LIGHTING All Wolf Pro ventilation hoods and hood liners have halogen lighting with two settings. Halogen bulbs are included with the hood. Pro wall hoods, 30" (762), 36" (914) and 42" (1067) wide require two 50W, 120V par 20 halogen bulbs. 48" (1219), 54" (1372), 60" (1524) and 66" (1676) wide hoods require three 50W, 120V par 20 halogen bulbs. Pro wall chimney hoods, 36" (914) and 42" (1067) wide require two 50W, 120V par 20 halogen bulbs. 48" (1219) and 54" (1372) wide hoods require three 50W, 120V par 20 halogen bulbs. Pro island hoods, 36" (914) and 42" (1067) wide require two 50W, 120V par 20 halogen bulbs. 54" (1372) and 66" (1676) wide hoods require three 50W, 120V par 20 halogen bulbs. Pro hood liners, 34" (864), 40" (1016) and 46" (1168) wide require two 50W, 120V MR-16 halogen bulbs. 52" (1321) and 58" (1473) wide hood liners require three 50W, 120V MR-16 halogen bulbs. To replace halogen bulbs, turn off the ventilation hood blower and lights. Once the halogen bulb is cool, use a soft cloth to unscrew the bulb and replace. Be sure that the bulb is cool before replacing. Halogen bulbs get hot instantly and adjacent parts may retain heat. HEAT LAMPS Wolf Pro 27" (686) deep wall hoods are equipped with two heat lamp locations that require R40, 250W maximum bulbs. Heat lamp bulbs are not included with the hood. To replace, turn off the ventilation hood blower and lights. Once the heat lamp bulb is cool, use a soft cloth to unscrew the bulb and replace. Be sure that the heat lamp bulb is cool before touching. Dimensions in parentheses are in millimeters unless otherwise specified. WOLF PRO VENTILATION HOOD USE & CARE SIGNATURE POLISH Signature Polish is available from Signature Limited Laboratory, P.O. Box 13436, Dayton, Ohio 45413-0436, or call 877-376-5474 (toll free). CLEANING AND CARE Most surfaces of your Wolf Pro hood are stainless steel. Although resistant to most stains, it is not totally impervious to damage. GENERAL CLEANING Salt and some cooking liquids may pit and stain the surface. Always remove any film or spills immediately. Avoid using abrasive cleaners. Th...

Otros modelos de este manual:
Los aficionados - PW482210R (213.5 kb)
Los aficionados - PW482210R (213.5 kb)
Los aficionados - PWC482418R (213.5 kb)
Los aficionados - PW482718R (213.5 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría