Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Miele, modelo DA 6480

Fabricar: Miele
Tamaño del archivo: 1.46 mb
Nombre del archivo: DA64x0_us.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Note all installation dimensions and guidelines regarding ventilation systems. - Be aware of kitchen cabinets, back splashes and/or racks in the area of the ventilation system and the cooktop. Ensure that the area where the vent rises is free of obstacles. - Make sure that any required minimum distance between the front edge of the countertop and the front edge of the cooktop is maintained. - If there is a drawer in the way, it must be shortened or removed. The front panel of the drawer could also be installed to permanently cover the drawer cut-out. 23 Appliance dimensions Installation using the DAG 500 internal blower DAG 500 mounted in front of the DAG 500 mounted behind the exhaust exhaust system. system. Note that the blower must be accessible to install the venting ductwork. 24 Appliance dimensions Installation using the DAG 1000 external blower connection plate Exhaust air ducting to the front. Exhaust air ducting to the rear. Note that the back must be accessible for the installation of the vent duct. 25 Installation The ventilation system is installed directly behind the cooktop. For easiest installation, install the ventilation system first, then the cooktop. The ventilation system must not be installed in an area where there are strong drafts, for instance near windows, doors, etc. Before installation, please read the "Appliance dimensions" and "Important safety instructions". ■ Remove the connection plate from the front of the appliance. Installation preparation ■ Remove the side screws at the top of the housing, put the top mounting brackets in place and screw them into place. ■ Screw the bottom mounting brackets to the side of the housing using 2 screws each. Do not tighten the screws. The brackets are different for the right and the left side. Attach them with mounting clip "A" pointing up. ■ Alternatively the bracket can be attached to the front of the appliance. Use the housing screws which were initially removed. 26 Installation ■ With the assistance of another person, lift the appliance into the prepared cutout. The top mounting brackets should rest on the countertop. ■ Secure the appliance to the countertop with 2 screws. Alternatively, or additionally, the appliance can also be attached underneath the countertop with the angle brackets provided. ■ First, loosely screw the brackets into the sliding nuts in the housing, then push them up under the countertop. ■ Now tighten the brackets on the housing. ■ Carefully pre-drill the mounting holes into the countertop from underneath. Using screws of the appropriate length. ■ Level and align the appliance. ■ Push the bottom mounting bracket on each side down against the cabinet floor. Mark the top edge of the mounting bracket on the housing and the mounting holes on the cabinet floor. 27 Installation ■ Remove the screws from the countertop. ■ Lift the appliance back out of the cabinet. ■ Pre-drill the marked mounting holes on the cabinet floor. ■ Tighten the mounting brackets on the appliance at the marked position. ■ Lay the vent housing on the floor on a blanket or other suitable protection in order to mount the DAG 500 blower or DAG 1000 blower adapter. Decide on the venting direction. If the ventilation system is installed in a cabinet, the vent duct can go through the floor, the right or left side, or to the rear of the cabinet. Installing the DAG 500 blower box on the front Venting to the side or downwards: ■ Plug the connection cable from the ventilation system into the blower motor. ■ Turn the blower box so that the vent collar faces in the desired direction -left, right or downwards. ■ Mount the blower box to the housing with 4 screws. 28 Installation Venting direction towards the rear: In this case, the DAG 500 blower box must be modified. ■ Loosen the two screws holding the blower in the box. ■ Take the blower out of the box. ■ Remove the small cover on the rear of the ventilation system. ■ Mount the blower on the front of the ventilation system housing using the 2 screws while positioning the vent collar in the opening of the cover. 29 Installation ■ Plug the connection cable from the ventilation system into the blower motor. ■ Remove the vent collar of the blower box. ■ Close the opening in the blower box with the cover you removed from the rear of the ventilation system housing. Fasten it with 4 screws. ■ Mount the vent collar on the rear of the ventilation system. ■ Mount the blower box to the housing with 4 screws. 30 Installation Installing the DAG 500 blower box on the rear The blower box can also be installed on the back of the ventilation system: ■ When finished, mount the previously removed cover on the front. ■ Remove the large cover on the rear. Mounting is the same as if installing on the front. ■ Mount the blower on the rear the same way as described for mounting on the front. 31 Installation Preparing the electrical connection box. ■ Decide wh...

Otros modelos de este manual:
Los aficionados - DA 6490 (1.46 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría