Iniciar sesión:
Votos - 3, Puntuación media: 4.7 ( )

Manual de usuario Lifebreath, modelo 195TRV

Fabricar: Lifebreath
Tamaño del archivo: 271.38 kb
Nombre del archivo: b72c0c00-ebb0-fa64-01af-77f70d00c8de.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The TRV is specifically designed for moderate/ temperate geographies with winter temperatures below freezing and summer conditions that are hot and humid. (Typically >75°F and 65% R.H.) The TRV is a new concept in ventilation that provides the compounded benefits of moisture transfer with unmatched heat recovery in a single unit. This new configuration is the only way to ensure year round temperature and moisture transfer. TRV TOTAL RECOVERY VENTILATOR • ASHRAE 62.2 Ventilation Standards • Sensible and Latent transfer for all 12 months • Adjustable ventilation rates with ControlAir 15 - 5 selectable speeds • Automatic damper defrost • Intermittent operation WWW .LIFEBREA TH.COM Today’s homes require controlled ventilation to improve the Indoor Air Quality and maximize energy efficiency. The TRV is specifically designed for moderate/ temperate geographies with winter temperatures below freezing and summer conditions that are hot and humid. (Typically >75°F and 65% R.H.) The TRV is a new concept in ventilation that provides the compounded benefits of moisture transfer with unmatched heat recovery in a single unit. This new configuration is the only way to ensure year round temperature and moisture transfer. TRV TOTAL RECOVERY VENTILATOR • ASHRAE 62.2 Ventilation Standards • Sensible and Latent transfer for all 12 months • Adjustable ventilation rates with ControlAir 15 - 5 selectable speeds • Automatic damper defrost • Intermittent operation Total Recovery Ventilator Model 195TRV/300TRV ENGINEERING DATA MOTORS AND BLOWERS -Each air stream has one centrifugal blower driven by a common PSC motor. 5 speed fan operation. 120 VAC, 1.5 Amps. FILTERS -Washable air filters in exhaust and supply air streams. MOUNTING THE TRV -Four threaded inserts at corners of case designed to accept four reinforced polyester straps that are supplied with the unit. DEFROST -Damper defrost system. DEHUMIDISTAT -Adjustable Internal Dehumidistat. CASE -Twenty gauge prepainted galvanized steel (G60) for superior corrosion resistance. Insulated to prevent exterior condensation. Drain connections 2 -1/2" (12 mm) OD. CONTROLS -ControlAir 15 -Standby/ON mode, 20 ON/ 40 OFF mode, Recirculation mode (on compatible units), (each mode has 5 speeds). Control pad can be removed from HRV and remotely mounted. WEIGHT 106 lbs. (48 kg) SHIPPING WEIGHT 108 lbs. (49 kg) PERFORMANCE Net supply airflow in cfm (L/s) against external static pressure 195TRV 300TRV E.S.P @ 0.1” (25 Pa) @ 0.2” (50 Pa) @ 0.3” (75 Pa) @ 0.4” (100 Pa) @ 0.5” (125 Pa) cfm L/s 203 (96) 191 (90) 182 (86) 167 (79) 155 (73) cfm L/s 265 (125) 260 (123) 250 (118) 235 (111) 220 (104) VAC @ 60HZ 120 120 WATTS / Low speed 100 150 WATTS / High speed 173 333 Amp rating 1.5 2.9 HIGH SPEED* MEDIUM HIGH SPEED MEDIUM SPEED MEDIUM LOW SPEED LOW SPEED 4 5 3 2 1 4 3 2 1 5 *Manufacturers Data 300TRV HIGH SPEED* MEDIUM HIGH SPEED MEDIUM SPEED MEDIUM LOW SPEED LOW SPEED 4 5 3 2 14 3 2 1 5 195TRV 125 75 100 50 75 0.1 0.2 0.3 0.4 0.5 0.6 0.7 ...

Otros modelos de este manual:
Los aficionados - 300TRV (271.38 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría