Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Dacor, modelo EI30WC40GS

Fabricar: Dacor
Tamaño del archivo: 291.05 kb
Nombre del archivo: 316488521en.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Do not have a fuse in the neutral or ground circuit. IMPOR IMPORIMPORIMPORIMPORIMPORT TTTTTANT ANTANTANTANTANT Save Installation Instructions for electrical inspector’s use. The range hood must be connected with copper wire only. The range hood should be connected directly to the fused disconnect (Or circuit breaker) box through metal electrical conduit. Wire sizes must conform to the requirements of the National Electrical Code ANSI/NFPA 70 — latest edition*, or CSA Standards C22.1-94, Canadian Electrical Code Part 1 and C22.2 No. 0-M91 - latest edition** and all local codes and ordinances. A U.L.- or C.S.A.-listed conduit connector must be provided at each end of the power supply conduit (at the range hood and at the junction box). Copies of the standards listed may be obtained from: * National Fire Protection Association Batterymarch Park Quincy, Massachusetts 02269 ** CSA International 8501 East Pleasant Valley Road Cleveland, Ohio 44131-5575 Before installing the hood • Use the shortest and straightest duct route possible. Refer to “Ductwork installation guidelines Ductwork installation guidelinesDuctwork installation guidelinesDuctwork installation guidelinesDuctwork installation guidelines Ductwork installation guidelines” paragraph for further informations. Vent unit to outside of building, only. 2. 2.2.2.2. 2. At least two people are necessary for installation. 3. 3.3.3.3. 3. The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall. 4. 4.4.4.4. 4. Do not use flex ducting. 5. 5.5.5.5. 5. COLD WEATHER installations should have an additional backdraft damper installed to minimize backward cold air flow and a nonmetallic thermal break to minimize conduction of outside temperatures as part of the ductwork. The damper should be on the cold air side of the thermal break. The break should be as close as possible to where the ducting enters the heated portion of the house. 6. 6.6.6.6. 6. Make up air: Local building codes may require the use of Make-Up Air Systems when using Ducted Ventilation Systems greater than specified CFM of air movement. The specified CFM varies from locale to locale. Consult your HVAC professional for specific requirements in your area. List of Materials List of Materials Parts Included with your Hood Parts Included with your HoodParts Included with your HoodParts Included with your HoodParts Included with your HoodParts Included with your Hood • Hood Canopy Assembly with Round Metal Transition installed. • Rectangular Metal Transition with Back draft dampers. • Care & Use /Installation Instructions • 2 Filters • Fitting Screws. Parts Not Included with your Hood Parts Not Included with your HoodParts Not Included with your HoodParts Not Included with your HoodParts Not Included with your HoodParts Not Included with your Hood • Lamps are not supplied, use ONLY 120 Volt, 50 Watt (maximum) 50° halogen light made or a GU10 base. Optional Accessories Optional AccessoriesOptional AccessoriesOptional AccessoriesOptional AccessoriesOptional Accessories • Charcoal Filter T TTTTTools/Materials r ools/Materials rools/Materials rools/Materials rools/Materials rools/Materials requir equirequirequirequirequired ededededed 1/2" Conduit Wire Nuts Flat blade and Phillips screwdrivers Pencil Metal snips (in some applications) Electric drill Saw (saber or keyhole) Duct tape Pliers Level Caulking Tape measure 1/4.pivoting hex socket Flashlight Wire stripper 1/4. Nutdriver Small hammer Round or Rectangular Duct. Round back draft damper Wiring clamp Installing the hood Installing the hood • •••••For the most efficient air flow exhaust, use a straight run or as few elbows as possible. Refer to “Ductwork installation guidelines Ductwork installation guidelinesDuctwork installation guidelinesDuctwork installation guidelinesDuctwork installation guidelines Ductwork installation guidelines” paragraph for further informations. Vent unit to outside of building, only. • •••••On avarage 2 hours are necessary to complete installation (without considering cut to be done on wall and or on cabinet, installation of ducts , conduit and electrical connections to the mains). • •••••The hood is fitted with Screws and Drywall Anchors suitable for most surfaces, consult a Qualified Installer, check if they perfectly fit with your cabinet/wall. • ••••• Do not use flex ducting. • •••••COLD WEATHER installations should have an additional backdraft damper in...

Otros modelos de este manual:
Los aficionados - EI30WC40GS (291.05 kb)
Los aficionados - EI30WC40GS (291.05 kb)
Los aficionados - 316488521 (291.05 kb)
Los aficionados - EI30WC40GS (291.05 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría