Manual de usuario CFM, modelo HRV-24

Fabricar: CFM
Tamaño del archivo: 416.65 kb
Nombre del archivo: fe96db40-2a50-4ce7-b736-68704f5e7832.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


INSIDE BASE E B A FAN PANEL DIMENSION G DAMPER (OPTIONAL) CURB DIMENSIONS IN INCHES* PERFORMANCE RATING WT (LBS) MAX MTR MINIMUM MAXIMUM MAXIMUM CFM MODEL A B D E G LESS MTR FRAME HP MODEL CFM CFM WITH FILTERS HRV-24 30 54 x 64 41.5 39 25.5 324 145T 1/4 - 1 HRV-24 800 6,700 4,861 HRV-30 36 60 x 76 41.5 45 25.5 365 145T 1/3 - 11/2 HRV-30 800 11,800 11,800 HRV-36 42 72 x 82 45.5 51 27.5 410 145T 1/3 - 2 HRV-36 1,800 15,376 13,889 HRV-42 48 80 x 89 45.5 57 27.5 503 184T 1/2 - 3 HRV-42 3,300 22,296 16,000 HRV-48 54 87 x 95 49.5 63 29.5 630 184T 3/4- 5 HRV-48 4,283 30,900 18,750 HRV-54 60 92 x 98 50.5 69 29.5 870 215T 1 - 5 HRV-54 8,000 35,238 19,333 HRV-60 66 90 x 107 54.5 75 31.5 1140 215T 1 - 10 HRV-60 9,600 47,000 21,333 *DO NOT USE FOR CONSTRUCTION CONSULT FACTORY FOR CERTIFIED PRINTS H HHR RRV VV H HHO OOO OOD DDE EED DD R RRO OOO OOF FF V VVE EEN NNT TTI IIL LLA AAT TTO OOR RRS SS P PPR RRO OOD DDU UUC CCT TT S SSP PPE EEC CCI IIF FFI IIC CCA AAT TTI IIO OON NN G GGU UUI IID DDE EE 1 11. ..0 00 G GGE EEN NNE EER RRA AAL LL A. Fans shall be model HRVD Direct Drive or HRVB Belt Drive Hooded Roof Ventilators as manufactured by Continental Fan Manufacturing Inc., of Buffalo, NY, and of the size and capacity as indicated on the drawings and fan schedule. B. HRVD or HRVB Hooded Roof Ventilators shall be furnished as either supply or exhaust as indicated on the drawings and fan schedule. C. HRVD or HRVB Hooded Roof Ventilators configured for supply shall be furnished with filters as indicated on the drawings and fan schedule. D. Fans shall be rated and tested in accordance with ANSI/AMCA Standard 210-99. E. All motors and electrical components shall conform to NEMA standards. 2 22. ..0 00 F FFA AAN NN H HHO OOU UUS SSI IIN NNG GG - --D DDI IIR RRE EEC CCT TT D DDR RRI IIV VVE EE M MMO OOD DDE EEL LL H HHR RRV VVD DD A. Fan shall be axial flow, roof mount, and direct drive configuration consisting of a hood section and fan housing with curb base. B. Fan housing and curb base shall be of welded heavy gauge steel construction. C. Fan motor base shall consist of heavy gauge steel welded directly to fan housing. D. Fan housing and motor base shall be coated with an air dried gray enamel finish. E. Fan shall have an aluminum hood with bird screen. 2 22. ..1 11 F FFA AAN NN H HHO OOU UUS SSI IIN NNG GG - --B BBE EEL LLT TT D DDR RRI IIV VVE EE M MMO OOD DDE EEL LL H HHR RRV VVB BB A. Fan shall be axial flow, roof mount, and belt drive configuration consisting of a hood section and fan housing with curb base. B. Fan housing and curb base panel shall be of welded heavy gauge steel construction. C. Fan motor, shaft and bearings support base shall consist of heavy gauge steel welded directly to fan housing. D. Fan housing and motor base shall be coated with an air dried gray enamel finish E. Fan shall have an aluminum hood with bird screen. 3 33. ..0 00 F FFA AAN NN I IIM MMP PPE EEL LLL LLE EER RR A. Axial impeller shall be constructed of spark resistant, die c...

Otros modelos de este manual:
Los aficionados - HRV-0904 (416.65 kb)
Los aficionados - HRV-30 (416.65 kb)
Los aficionados - HRV-36 (416.65 kb)
Los aficionados - HRV-42 (416.65 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría