Manual de usuario Invacare, modelo Jasmine JLS5

Fabricar: Invacare
Tamaño del archivo: 545.15 kb
Nombre del archivo: 1152408B.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


In case of shipping damage, DO NOT use. Contact carrier/dealer for further instruction. To ensure the safe installation, operation and use of the Jasmine Scale, these instructions MUST be followed: WARNING DO NOT use this equipment without first reading and understanding these instructions. If you are unable to understand the Warnings, Cautions, and Instructions, contact distributor before attempting to use this equipment, otherwise, injury or damage may result. The weight capacity is limited to the lowest rated capacity of any one of the components in use (i.e., Patient Lift, Sling or Scale). The patient’s weight MUST NOT exceed the lowest rated capacity of any component. After ANY adjustments, repair or service and before use, make sure that all attaching component parts are secure. ACCESSORIES WARNING Invacare products are specifically designed and manufactured for use in conjunction with Invacare accessories. Accessories designed by other manufacturers have not been tested by Invacare and are not recommended for use with Invacare products. Kit Description DESCRIPTION QUANTITY Load Cell Assembly 1 Nylon Washers 2 Swivel Bar Pin 1 Locknut 1 Mounting Screw 1 Small Steel Washer 1 Specifications Weight Range: Up to 500 lbs (226.7 Kg) Resolution: +/- 0.2 lbs (0.1 Kg) Display: Liquid Crystal Digital Automatic Power Down: Two minutes Size: 5-3/4 L X 3-5/8 W X 4 H Weight: .55 lbs Power: 9-Volt Alkaline battery (included) Battery Life: Approximately 1500 readings Temperature Range: 50° To 104°F (10° To 40°C) For more information regarding Invacare products, parts, and services, please visit Part No 1152408 1 Jasmine™ Scale JLS5 Removing the Swivel Bar/Cradle Attachment NOTE: For this procedure, refer to FIGURE 1. 1. Remove the side rubber caps. NOTE: Support the swivel bar or cradle attachment from underneath while removing the attaching hardware. 2. Remove the socket head screw, washer, bushings, top rubber cap, nylon spacers, washer and nut that attach the swivel bar or cradle attachment to the boom. NOTE: When the attaching hardware is removed, the pin, washer and o.ring will become loose. NOTE: Save the socket screw, small steel washer and locknut to secure the Jasmine Scale to the boom. NOTE: Save the remaining hardware for future use of the swivel bar or cradle attachment without the scale. Top Rubber Cap Side Rubber Cap Nut Washer Nylon Spacer Nylon SpacerSide Rubber Cap Socket Head Screw Washer Bushing Swivel Bar Bottom Rubber Cap Pin O-ring Washer Optional Cradle AttachmentBushing FIGURE 1 Removing the Swivel Bar/Cradle Attachment Jasmine™ Scale JLS5 2 Part No 1152408 Installing the Jasmine Scale NOTE: For this procedure, refer to FIGURE 2. WARNING Patient and sling MUST be removed from the lift during ALL installation procedures. 1. Position the load cell assembly of the Jasmine Scale into the boom mounting bracket (Detail .A. of FIGURE 2). 2. Secure the Jasmine Scale to the boom mounting bracket with a bolt, washers, bushings, nylon washers, locknut and the top rubber cap. Securely tighten. Install the small rubber cap. NOTE: Refer to Detail .A. of FIGURE 2 for washer and small rubber cap orientation. NOTE: Ensure the shaft of the bolt passes through both sides of the boom mounting bracket. 3. Insert swivel bar pin with an o.ring and a washer through the swivel bar (Detail .B. of FIGURE 2). 4. Align the mounting holes in the swivel bar pin with the mounting holes in the load cell assembly (Detail .B. of FIGURE 2). 5. Secure swivel bar pin to the load cell assembly with a screw and locknut. Tighten securely (Detail .B. of FIGURE 2). WARNING After ANY adjustments, repair or service and BEFORE use, make sure all attaching hardware is tightened securely - otherwise injury or damage may occur. 6. Weigh the patient. Refer to Operating the Scale and Weighing the Patient in the Jasmine Patient Lift Owner’s Manual, Invacare P/N 1150704. Locknut Swivel Bar Washer Swivel Bar Pin Screw Jasmine Scale Jasmine Scale Load Cell Assembly Bolt DETAIL “B”DETAIL “A” Locknut Nylon Washers Washer O-Ring Top Rubber Cap Bushing Small Rubber Cap Boom Mounting Bracket Bushing Washer FIGURE 2 Installing the Jasmine Scale Part No 1152408 3 Jasmine™ Scale JLS5 Operating the Scale Keypad Functions KEY INDICATOR DISPLAYED INDICATOR LOCATION DEFINITION ON OFF OFF Center of Display Window Pressing this key will apply power to the scale and turn the unit on. When the scale is already on, pressing the button will turn the unit off. ZERO ZERO Lower Left Corner of the Display Window Pressing this key when the scale is on will reset the weight shown in the display window to zero. UNITS lb or kg Upper Right Corner of the Display Window The function of this key is to change the unit of measurement from pounds (lb) to kilograms (kg). LOCK UNLOCK LOCK Lower Right Corner of the Display Window This key is used to LOCK or UNLOCK a weight value in the display window. NOTE: Weight displayed is a STORED weight and not the current...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría