|
Resumen del manual
To record on a tape again, cover the tab hole with adhesive tape. ED Safety tab Tips • To edit more precisely, press the II PAUSE buttons on the units to release pause. • To cut out unwanted scenes while editing, press II PAUSE on this unit when an unwanted scene begins. When that scene ends, press I PAUSE again to resume recording. Note • (SLV-XA147PS and XF247ME/PS only) You can record tapes only in SP mode. 20 Additional Operations Additional Information Troubleshooting If you have any questions or problems not covered below, please consult your nearest Sony service facility. Symptom Remedy The ON/STANDBY switch does not function. • Connect the mains lead securely The power is turned on but the unit does not operate. • Moisture condensation occurs. Turn the power off, unplug the mains lead and leave the unit to dry for over an hour. g The VCR enters standby mode ow or turns off automatically. Cl • The auto safety system is triggered to protect your tape and the unit's mechanism when there is something wrong with the tape or when the mechanism is overloaded. Press ON/STANDBY to restart the unit. If the unit does not work after pressing ON/STANDBY again, disconnect the mains lead from the mains. Wait for at least 15 seconds. Then reconnect mains, and press ON/STANDBY again. If the unit still does not work, please consult your nearest Sony service facility The playback picture does not appear on the TV screen. • Make sure the TV is set to the video channel. If you are using a monitor, set it to video input. The picture is not clear. c a b y Cl • Adjust the tracking with the $/4 TRACKING NORMAL/SLOW buttons. • Make sure the COLOR SYSTEM switch is set to the position corresponding to the colour system which the tape was recorded with. • The video heads are dirty (see the next page). Clean the video heads using a video head cleaning cassette. If a cleaning cassette is not available in your area, have the heads cleaned at your nearest Sony service facility (a standard service charge will be required). Do not use a commercially available wet-type cleaning cassette, as it may damage the video heads. • The video heads may have to be replaced. Consult your local Sony service facility for more information. The picture rolls vertically during picture search. • Adjust the vertical hold control on the TV or monitor. The picture has no sound. • The tape is defective. Use a new tape. continued Additional Information 21 Troubleshooting (continued) Symptom Remedy The tape starts playing as soon as it is inserted. • The safety tab has been removed. To record on this tape, cover the tab hole. Recording The tape is ejected when you press 0 REC. • Check that the safety tab has not been removed. Nothing happens when you press 0 REC. • Make sure the tape is not at its end. • (SLV-XF247ME/PS only) Select the correct source with the INPUT SELECT switch, LINE 1 or LINE 2. No tape can be inserted. • Check that a tape isn't already in the tape compartment. Others The remote commander does not function. • Make sure you are pointing the remote commander at the remote sensor on the unit. • Replace all the batteries in the remote commander with new ones if they are weak. The unit needs to be cleaned. • Clean the cabinet, panel, and controls with a dry soft cloth, or a soft cloth slightly moistened with a mild detergent solution. Do not use any type of solvent, such as alcohol or benzine. Auto head cleaner The unit incorporates an auto head cleaner which cleans the video heads when a tape is loaded or unloaded. When the heads are not sufficiently clean, even after a tape has been loaded/unloaded several times, use a video head cleaning cassette. Symptoms caused by contaminated video heads • Normal picture • Rough picture • Unclear picture • No picture (or black & white screen appears) initial -terminal Sapphire tape cleaner The unit incorporates a sapphire tape cleaner which cleans a video tape when it is loaded. This cleaner can prevent the video heads from contamination by removing dust or mold from a tape with the sapphire edge. 22 Additional Information Specifications System RF output signal UHF channels 30 to 39 Aerial out 75-ohm asymmetrical aerial socket Inputs and outputs LINE IN (SLV-XA147JE/MJ/PS) LINE 1 IN/LINE 2 IN (SLV-XF247ME/PS) VIDEO IN, phono jack (1) Input signal: 1 Vp-p, 75 ohms, unbalanced, sync negative AUDIO IN, phono jack (1) (SLV-XA147JE/MJ/PS) phono jack (2) (SLV-XF247ME/PS) Input level: 327 mVrms Input impedance: more than 47 kilohms LINE OUT (SLV-XA147JE/MJ/PS) LINE 1 OUT (SLV-XF247ME/PS) VIDEO OUT, phono jack (1) Output signal: 1 Vp-p, 75 ohms, unbalanced, sync negative AUDIO OUT, phono jack (1) (SLV-XA147JE/MJ/PS) phono jack (2) (SLV-XF247ME/PS) Standard output: 327 mVrms Load impedance: 47 kilohms Output impedance: less than 10 kilohms General Power requirements 110 - 240 V AC, 50/60 Hz Power consumption 10 W Operating temperature 5°C to 40°C Sto...
Otros modelos de este manual:VCR / vídeo - SLV-XF247ME (323.42 kb)