Iniciar sesión:
Votos - 3, Puntuación media: 4.3 ( )

Manual de usuario ADT Security Services, modelo PowerSeries SCW9047-433

Fabricar: ADT Security Services
Tamaño del archivo: 506.74 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Ensure that no zones are unintentionally 4 bypassed when arming your system. Zones cannot be bypassed once the system is armed. Bypassed zones are automatically cancelled each time the system is disarmed and must be bypassed again, if required, before the next arming. Bypassing Zones With the system disarmed. 1. Press to enter the function menu. The keypad will display “Press 4 for < > Zone Bypass”. 2. Press or , then your [access code] (if required). The keypad will display “Scroll to < > Bypass Zones”. 3. Enter the two-digit number of the zone(s) to be bypassed (01-34). You can also use the keys to find the zone to be bypassed, and then press to select the zone. The keypad will display “Zone Name”. “B” will appear on the display to show that the zone is bypassed. If a zone is open (e.g., door with door contact is open), the keypad will display “Zone Name” O”. If you bypass the open zone, a “B” will replace the “O”. 4. To unbypass a zone, enter the two-digit number of the zone(s) to be bypassed (01-34). You can also use the keys to find the zone, and then press to select the zone. The “B” will disappear from the display to show that the zone is no longer bypassed. 5. To exit bypassing mode and return to the Ready state, press . Activating All Bypassed Zones To remove bypass (all zones): 1. Press , then your [access code] (if necessary). 2. Press . 3. To exit bypassing mode and return to the Ready state, press . Recalling Bypassed Zones To recall the last set of bypassed zones: 1. Press , then your [access code] (if necessary). 2. Press . 3. To exit bypassing mode and return to the Ready state, press . Bypass Group A Bypass Group is a selection of zones programmed into the system. If you bypass a group of zones on a regular basis, you can program them into the Bypass Group, so that you do not have to bypass each zone individually every time. Only one Bypass Group can be programmed. NOTE: If a group has already been bypassed before programming a Bypass Group, you will be unable to recall that group after programming the new group. To program a Bypass Group: 1. Press , then your [access code] (if necessary). 2. Enter the two-digit numbers (01-34) of the zones to be included in the Bypass Group or use the keys to find the zone to be included in the bypass group, then press to select the zone. 3. To save the selected zone into the group, press . 4. To exit bypassing mode and return to the Ready state, press . NOTE: If an access code is required to enter bypassing, only the Master Code and codes with Supervisory enabled can set the Bypass Group. 5 To select a Bypass Group when arming the system: 1. Press , then your [access code] (if necessary). 2. Press . The next time the system is armed, the zones in this group will be bypassed. 3. To exit bypassing mode and return to the Ready state, press . NOTE: A Bypass Group is only recalled if the system is armed/disarmed after programming the bypass group. NOTE: This feature is not to be used in UL Listed installations. Trouble Conditions When a trouble condition is detected, the Trouble ( ) indicator will turn on, and the keypad will beep every 10 seconds. Press the key to silence the beeps. Press to view the trouble condition. The Trouble ( ) indicator will flash. Use the keys to view troubles. Trouble Condition Comments Action Service Required (Press [1] for more information) Indicates Low Battery, System Trouble, System Tamper or RF Jam detected. Call for service Loss of AC Power If the building and/or neighbourhood has lost electrical power, the system will continue to operate on battery for several hours. Check AC connection Call for service Telephone Line Fault The system has detected that the telephone line is disconnected. Call for service Failure to Communicate The system attempted to communicate with the monitoring station, but failed. This may be due to Telephone Line Fault. Call for service Sensor (or Zone) Fault The system is experiencing difficulties with one or more sensors on the system. Press [5] to display zone(s). Call for service Sensor (or Zone) Tamper The system has detected a tamper condition with one or more sensors on the system. Press [6] to display zone(s). Call for service Sensor (or Zone) Low Battery If the system has been equipped with wireless sensors, one or more has reported a low battery condition. Press [7] to display the zone(s). Press [7] again to display WLS keys. Call for service Loss of Time & Date If complete power was lost (AC and Battery), the time and date will need to be re-programmed. Press [*] Re-program Time & Date (page 4) Alarm Memory When an alarm occurs, the Alarm Memory Message will be displayed. To view which sensor(s) generated the alarm, press . For the system keypad use the scroll keys to view the sensors in alarm memory. Press to exit. To clear the memory, arm and disarm the system. If an alarm sounded while armed, the system will automatically go to alarm memory when you disarm the system. In this instance, yo...

Otros modelos de este manual:
Vídeo - PowerSeries SCW9045-433 (506.74 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría