Iniciar sesión:
Votos - 5, Puntuación media: 3.8 ( )

Manual de usuario Panasonic, modelo AWRP301

Fabricar: Panasonic
Tamaño del archivo: 587.73 kb
Nombre del archivo: AWRP301.PDF
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Various pan/tilt control signals can be sent and received through a single 10BASE-T (UTP category 5) cable per pan/tilt head. ' • The maximum distance from this control panel to the camera and pan/tilt head is 500 meters. • Head pan/tilt and lens zoom/focus can be controlled at varying speeds with the servo control, and can be preset at up to 10 points per pan/tilt head. With the auxiliary control input connector (AUX CONTROL IN), pan/tilt, zoom, focus, and iris operations can be externally controlled. PRECAUTIONS • Use only with AC Adaptor AW-PS301. • Handle the control panel with care. Dropping the control panel or subjecting it to a strong shock can cause a failure or an accident. • Operating temperature range -10°C to +45°C Avoid using it in a cold place below -10°C or a hot place above +45°C because low or high temperature will adversely affect the parts inside. • Switch power off before power cable connection or disconnection. Be sure to switch power off before connecting or disconnecting the power cable. • Avoid outdoor use. • Install the control panel more than 1 meter away from the monitors. * Care Pull out the power cable plug, and wipe the control panel clean with a dry cloth. If it is extremely dirty, dtp a cloth into a diluted solution of kitchen detergent, squeeze it hard, and wipe the product surfaces carefully. — Note- • Do not use benzine, paint thinner, or other volatile liquids. • When using a chemical duster, carefully read the caution notes on its use. — Precautions in Using Halogen Lamp- Set the power control switch to the OFF position after setting the lamp switch to the OFF position. Halogen lamp power will not be switched off if the AC adapter for the AW-RP301 .AW-RP305 is disconnected or if the main circuit breaker is opened while the halogen lamp is in MAJOR OPERATING CONTROLS AND THEIR FUNCTIONS l Control Panel AW-RP301 AW-RP305 Ftanasofric -4- O Power Indicator [POWER] Lights red when POWER ON/OFF Switch 0 is in the ON position, and goes out when the same switch is set to the OFF position. O Power CONTROL Switch [POWER, ON/OFF] All the connected pan/tilt heads are switched on when this switch is set to the ON position. (The power indicator lights.) The pan/tilt head are partially switched off when this switch is set to the OFF position. Note: When the switch is set to the OFF position, the communication line between the pan/tilt head and this control panel remains live. To disconnect all power supply, pull out the power plug from the electrical outlet. O Tally Indicator [TALLY] On the AW-RP305, the LED corresponding to the TALLY Terminal €) from a Special Effect Generator (SEG) or video switcher. On the AW-RP305, the LED corresponding to the TALLY Terminal (one of [1] to [5]) to which a tally signal is input lights red. 0 Pan/tilt Head Selection Switch [CONTROL] (AW-RP305 only) Select a desired camera with pan/tilt head from among those connected to the control panel. When a camera with pan/tilt head is selected by pressing one of the buttons [1] to [5], the pressed button lights. Note: Even if an unconnected camera with pan/tilt head is selected by pressing the corresponding button, the button lights. 0 Lamp Indicator [LAMP] Lights red when LAMP ON/OFF Switch 0 is in the ON position. Flashes if the lamp connected to the AC Adapter (AW-PS300) for pan/tilt head is broken. Goes out when LAMP ON/OFF Switch © is set to the OFF position. Note: Use a halogen lamp of 250 W to 500 W to connect to the pan/tilt head AC Adapter (AW-PS300). If a lamp of lower than 250 W is connected to it, the LED may flash when LAMP ON/OFF Switch 0 is in the ON position even though the lamp is not broken. 0 Lamp Switch [LAMP, ON/OFF] Switches on and off the halogen lamp connected to the lamp AC receptacle of the Pan/tilt Head AC Adapter (AW-PS300). In case of the AW-RP305, first select a pan/tilt head with CONTROL Switch O, then switch on or off the lamp. Set it to the ON position to switch the halogen lamp on (in which case, the lamp LED flashes). Set it to the OFF position to switch the halogen lamp off. Note: In using the AW-RP305, when a pan/tilt head is selected with CONTROL Switch O, the halogen lamp connected to the AC adapter for the pan/tilt head selected with that switch lights or goes out depending on the position of LAMP Switch 0. Q Lens Iris Selection Switch [IRIS, AUTO/MANU] Select a lens iris selection mode with this switch. When this switch is in the AUTO position, the lens iris is automatically controlled according to the quantity of light entering the lens. When the switch is in the MANU position, the iris can be manually controlled over the range from the closed position to the fully open position using IRIS LEVEL Control ©. Set the switch to the MANU position in storing iris data in PRESET Switches © with MEMORY Switch ©. If the switch is in the AUTO position, iris data will not be stored in the memory. Note: Len iris data may be unable to b...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría