• Is REC LOCK on Menu Screen 1 at OFF? 1-week programmed timer recording cannot be conducted properly. • Are the date and time on the regular displays correct? (See page 11) One or more cameras do not record when a multiple number of cameras are used. • Turn the time adjustment control on the sequential switcher, and adjust it to a setting which is longer than the video recording duration in the recording time mode. • Connect a camera switching cable between the unit and sequential switcher. (See page 27) No auto repeat recording. • Has the stop button been pressed during auto rewinding? No timer recording. • Are the present time and start/stop times for the timer recording correct? • Has INT or EXT lighted on the display? No alarm recording. • Have the alarm sensors and alarm Input connectors been connected properly? • Has the alarm recording mode been selected on Menu Screen 2? ■ r r ■>,* «■: %. .£ ^Trouble w|t|§playb'ack - 1 J, Noise sometimes appears on the playback pictures. • Adjust the tracking buttons. (See page 28) Dirty playback picture. • The video heads may be dirty or clogged or they may have reached the end of their service life. Consult with your dealer. "Snow" on playback picture. • The video heads may be dirty or clogged. Consult with your dealer. While a multiple number of cameras are being used, two scenes appear as the playback picture when the cameras are switched. •. Has the camera switching signal cable been connected properly? Recording starts when the unit’s power plug is connected to or disconnected from the power outlet. • Has INT or EXT lighted on the display? No playback because recording starts when the main power for the connected equipment is set to ON. • Has INT or EXT lighted on the display? 30 Specifications Power Source: 120 V AC. 50 - 60 Hz Power Consumption: 18W Video Recording System: Tape Speed: Tape Format: Recording Time Modes: FF/REW Time: VIDEO Television System: Modulation System: Input: Output: Horizontal Resolution: S/N: 4 rotary heads, helical scanning 11.12 mm/s (8-hour mode) 3.71 mm/s (24-hour mode) 2.22 mm/s (40-hour mode) Tape width 12.7mm (1/2 inch), iVHS) tape 8/24/40 hours mode Approx. 3 min. (with NV-T160) EIA Standard (525 lines, 60 fields) NTSC color signal Luminance; Frequency modulation recording Color Signal; Converted subcarrier phase shift recording Video Input (BNC); 1 .OVp-p, 75ohms, unbalanced Video Output (BNC); 1 .OVp-p, 75ohms, unbalanced Color; More than 230 lines B/W; More than 300 lines Better than 43 dB (B/W, 8-hour mode) Better than 43 dB (color, 8-hour mode) AUDIO Input: Output: Tracks: CONNECTORS Alarm Input/Summer Time Setting Input: Alarm Reset Input: Operating Temperature: Operating Humidity: Weight: Dimensions: Audio Input (Phono); -10 dBV, 47 kohms, unbalanced Mic (Mini-jack); -60 dBV, 600ohms, unbalanced Audio Output (Phono); -8 dBV, 1 kohm, unbalanced 1 track Contact closure for alarm +4 - +14V 41°F - 104T (5°C - 40°C) 35% - 80% 11lbs (5.0kg) 101 Vi6"(W)x4%n(H)x13%"(D) 270x120x344.5 mm Weight and dimensions shown are approximate. Specifications are subject to change without notice. Input/Output Terminal Signal Level _Terminal Alarm Input/Summer Time Setting Input Signal Level Vil: 0 - 0.6 V MIN 400 msec. Note LOW Input Alarm Reset Input MIN 400 msec. _»| -1 Viht 4 — 14 V HIGH Input Camera Switching Output Video recording interval H-H ■Vih: 11 -13V Voh = 11-13V (5.6kß) Vol - 0-0.6V (max. 3 mA) 16.67 msec. Tape end output During auto repeat or auto rewinding Voh Vol When stopped i “I Voh: 11 -13 V - VOL Voh = 11-13V (4.7kQ) Vol = 0-0.6V (max. 3 mA) Approx. 10 sec. Warning output “L Vo«: 11 -13 V - VOL Voh = 11-13V (4.7kQ) Vol = 0-0.6V (max. 3 mA) 31 Panasonic Broadcast & Television Systems Company Division of Matsushita Electric Corporation of America CLOSED CIRCUIT VIDEO EQUIPMENT DIVISION Executive Office: One Panasonic Way (3E-7), Secaucus, NJ 07094 REGIONAL OFFICES: Northeast: 43 Hartz Way, Secaucus, NJ 07094 (201 ) 348-7303 Southeast: 1225 Northbrook Parkway, Suite 107A, Suwanee, GA 30174 (404) 717-6772 Midewest: 1707 North Randall Road, Elgin, IL 60123 (708) 468-5200 Southwest: 4500 Amon Carter Blvd., Fort Worth, TX 76155 (817) 685-1117 Western: 6550 Katella Ave., Cypress, CA 90630 (714) 373-7265 Panasonic Canada Inc. 5770 АтЫег Drive, Mississauga, Ontario L4W 2T3 (905) 624-5010 Panasonic Sales Company Division of Matsushita Electric of Puerto Rico Inc. San Gabriel Industrial Park, 65th Infantry Ave., Km. 9.5, Carolina, Puerto Rico 00630 Manuel d’instructions Magnétoscope à temps échelonné Panasonic’ Il est recommandé de lire attentivement ce manuel avant d’utiliser l'appareil. Imprimé au Japon VQT7701 S0698H100® Mise en garde: “L’enregistrement non autorisé d’émissions de télévision, films, rubans magnétoscopiques ou autres, protégés par des droits d’auteur, peut enfreindre les droits de propriété et aller à rencon...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría