Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Panasonic, modelo WJSX650

Fabricar: Panasonic
Tamaño del archivo: 2.46 mb
Nombre del archivo: WJSX650.PDF
Idioma del manual:entr
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Up to 59 operators can be registered. • User ID: ID number of operator controlling this unit. 1 to 99998 are available. Note: Begin the entry with a numeric other than "0". • Password: For login, a password is checked as well as a User ID. Up to 5 digits are available. Note: To protect system controllers from misuse, be sure to change the factory default passwords. • Level: An operator's restrict level. 1 to 5 are available. 1 is the highest, and 5 is the lowest. Note: Desired functions can be assigned to each level in "Operator" – "Level Table" of WJ-SX650 Series Administrator Console. • Priority: Operator priority given to control a monitor, camera, or recorder selected by another operator. 1 to 99 are available. 1 is the highest, and 99 is the lowest. • Camera Access: View and control can be enabled or disabled for each camera. VIEW & OPERATE: An operator can display the selected camera image on the selected monitor. The operator can also control the camera. VIEW: An operator can display the selected camera image on the selected monitor, but cannot control the camera. - -: The operator can neither display the selected camera image on the selected monitor nor control the camera. • Recorder Access: View and control can be enabled or disabled for each recorder. VIEW & OPERATE: An operator can display the selected recorder image on the selected monitor. The operator can also control the recorder. VIEW: An operator can display the selected recorder image on the selected monitor, but cannot control the recorder. - -: The operator can neither display the selected recorder image on the selected monitor nor control the recorder. • Monitor Access: Control can be enabled or disabled for each monitor. Notes: • Monitor Access is set for each DATA port. Operators logging into the system from the same DATA port have the common setting. • Monitor Access setting is not applied for operators logging into the system from the PC connected to the SERIAL port. • Monitor Access setting is performed in "Controller" – "Monitor Access" of WJ-SX650 Series Administrator Console. Power-on/off 1. To power on the unit, press the power switch behind the front panel. 2. Power on system controllers and recorders. (Refer to the operating instructions of each system device for how to power on.) 3. When finishing operations, power off each device in the same procedure as power on. Operation Start (Login) By logging into the system as a registered operator, you can control system devices with the authority of that operator. 1. Turn on the power. (Refer to Power-on/off.) 2. Wait until the login standby display appears. Note: If the password is wrong or no operation has been performed for 5 seconds or more, the LCD (or LED display) will return to the login standby display. 3. Enter the user ID by pressing numeric buttons, and press the CAM (SET) button. 4. Enter the password by pressing numeric buttons, and press the CAM (SET) button. The system controller will enter the login status, and the LCD (or LED display) will become the default status. Operation End (Logout) You need to log out of the system: • When finishing operations and powering off • When changing an operator WV-CU950/650 During the login status, press the LOGOUT button while holding down the SHIFT button. The LCD returns to the login standby display. WV-CU360C/CJ During the login status, press the LOG OUT button while holding down the SHIFT button. The LED display returns to the login standby display. Operation Start/End (Auto Login/Logout) • To activate auto login or auto logout, the setting is required in advance. • The auto login and auto logout settings is performed in "Controller" – "Auto Login/Logout" of WJ-SX650 Series Administrator Console. • Auto login and auto logout are set for each DATA port. Operators logging into the system from the same DATA port have the common setting. • When both auto login and auto logout are set for a DATA port, system controllers connected to the port perform login and logout automatically. Then, the system controller returns to the status before monitor selection. Monitor Control The following is the procedure examples for monitor operation. Refer to p. 73 Lists of Operations and Functions for other monitor control procedures not described here. Monitor Selection In the following procedure, you can display camera images or perform setup procedures on a desired monitor. 1. Enter the desired monitor number by pressing the numeric buttons. The entered number will appear on the LCD (or LED display). 2. Press the MON (ESC) button. The specified monitor will be selected, and the system will become ready for monitor control. 3. Control the selected monitor. Note: Even after you log out of the system or select another monitor, the camera image or sequence is continuously displayed on the selected monitor. Monit...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría