Iniciar sesión:
Votos - 5, Puntuación media: 4 ( )

Manual de usuario Panasonic, modelo AWRP50N

Fabricar: Panasonic
Tamaño del archivo: 827.07 kb
Nombre del archivo: AWRP50N.PDF
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


[Switcher settings] The IP address set in the [IP:SW] item from [SW IP ADR] on the [SYSTEM] menu will be set for the switcher. Notes .. Duplication in the IP addresses may arise when a device other than a remote camera or switcher has been connected within the same subnet. Connect only devices which are covered by the “Auto IP setting” within the same subnet. .. If a remote camera with the same IP address as the unit’s exists, the IP address of the remote camera concerned cannot be set by following the steps in “Auto IP setting”. .. When a multiple number of AW-RP50 remote camera controllers have been connected in the same subnet, do not perform the steps described in “Auto IP setting” using each controller at the same time. .. When the steps described in “Auto IP setting” have been performed by operating the unit, do not use the “Setup Software” (provided with the unit) in the host computer end at the same time. Similarly, do not use the “Easy IP Setup Software” provided with the AW-HE50 at the same time. Otherwise, the settings may not be established correctly. 26 Connections ..When setting the IP addresses for the first time The IP addresses are set while the remote cameras, switcher and unit are at their factory settings. Before setting the IP addresses, check that “NoAsign” is shown as the remote camera’s connection setting. Connection settings: On the [SYSTEM] menu, select [CAMERA CTL], and then display items [CAM1] to [CAM100]. Note 1 Connect the remote cameras, switcher and unit to the network within the same subnet. 192.168.000.010 .. 192.168.000.011 192.168.000.010 .. 192.168.000.010 192.168.000.010 .. 192.168.000.012 1.AUTO SETUP RENEW IP ADR 192.168.000.008 .. 192.168.000.008 192.168.000.009 2 On the [SYSTEM] menu, select [AUTO SET IP], and display [AUTO SETUP]. Then select “RENEW IP ADR”, and press the F2 dial. Both the number of devices (all remote cameras and the switcher) currently being managed by the unit and the number of new devices detected are displayed on the LCD panel. C:003/003 S:1/1 YES C:003/003 Number of devices currently managed by the unit + Number of new devices detected Number of new devices detected C: Remote camera, S: Switcher . Memo . .. If the number of new devices detected exceeds the number of devices that can be registered (100 remote cameras and 1 switcher), [C/S OVER!] will be displayed at the bottom of the LCD panel. Automatic IP address setting can be performed even in this state, but IP addresses will be set only for the number of devices that can be registered. C:020/100 S:1/1 C/S OVER! YES .. When a multiple number of remote cameras have been started up at the same time, for instance, it may not be possible for all of these cameras to be detected by the unit. In this case, select “RETRY”, and then press the F2 dial to retry the operation. The number of units to be added can be updated. .. The number displayed for “Number of new devices detected” may be lower than the actual number of devices to be set, due to a cause such as the remote cameras or switches not being powered on. In this case, eliminate the cause of the problem, select “RETRY”, and then press the F2 dial to retry the operation. The number of units to be added can be updated. C:020/020 S:1/1 RETRY 27 Connections 3 Turn the F2 dial, select “Yes”, and then press the F2 dial. This starts the “Auto IP setting” process. When “Auto IP setting” has been initiated, the progress is shown by the number of displayed dots which are reduced one by one. AUTO SETUP ...................... When all the operations have been completed successfully, “COMPLETE!” is displayed. AUTO SETUP COMPLETE! The remote cameras and the switcher are automatically rebooted, and they restart with the new IP addresses which were set. The remote cameras can now be operated from the unit. The function for linking the switcher with the unit becomes available for use at this point. . Memo . If the IP addresses were not set successfully, “SET UP ERR!” is displayed. AUTO SETUP SET UP ERR! The cause of the problem is likely a network malfunction. Check the connection status of the hub and LAN cables, and then retry the “Auto IP setting” operation. Connections ..When introducing additional remote cameras or a switcher into an environment where similar existing devices are already in use Even when additional remote cameras or switcher are introduced into an environment where similar existing devices are already in use, the settings can be easily established using “Auto IP setting”. There are two methods for setting the IP addresses of newly introduced devices (remote cameras or a switcher), as follows: 1. Setting the IP address from the unit 2. Changing the IP address on the unit to match the IP address of the remote camera or switcher This section explains each of these methods. Setting the IP address from the unit [Remote camera settings] The unit sets the IP addresses for the remote cameras that have been detected by associating them with ca...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría