Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario GE, modelo TRIPLEX 0150-0193C

Fabricar: GE
Tamaño del archivo: 1.08 mb
Nombre del archivo: dvmre-CT_triplex_man.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


· Event Record Rate: In pictures per second (pps). · Pre Event Duration: 0 to 5 seconds. · Post Event Duration: 0 to 200 seconds. · Acitvity Record Rate: In pictures per second (pps). · Record Quality: High, Medium, or Low. View Screen 5 Record Timer · DAY: 1-31, Mon, Tue, Wed, Thu, Fri, Sat, Sun, Mon-Fri, Sat-Sun, Mon-Sun · Start: Time (HH:MM) · Stop: Time (HH:MM) · Macro: Macro Number, On or Off View Screen 6 · Time and Date Display A: On or Off. · Time and Date Display B: On or Off. · Time Format · Date Format · Titles Display A: On or Off. · Titles Display B: On or Off. · Master Clock: Yes or No. · Multiscreen Dwell: In seconds. · Full Screen Dwell: In seconds. · Record Mode: No Overwrite, Write Once, or Continuous. · Auto Disable: On or Off. · Indicate Detection: On or Off. 0150-0193C 57 Calibur DVMRe Triplex View Screen 7 · Global Buzzer: On or Off. · Live Alarm Buzzer: On or Off. · Video Loss Buzzer: On or Off. · Playback Buzzer: On or Off. · Relay 1: Normally Open or Normally Closed. · Relay 2: Normally Open or Normally Closed. · Alarm Latch: T = Transparent, L = Latched, TO (020) = Timed Out (Time) · Alarm Record Mode: Interleaved, Exclusive, or No Change. · Full Screen Alarm: Yes or No. This feature is not available on the 4-Channel units. · Global Alarm Record Rate: In pictures per second (pps). · Pre Alarm Duration: In seconds. · Archive Alarm: Enable or Disable. View Screen 8 · Background Archive: On or Off. · Monitor Setup: Single or Dual. · Baud Rate Port 1 · Baud Rate Port 2 · Network Address · Ethernet: Enable or Disable. · POTS: Enable or Disable. · Language: English, German, or French. · Keyboard Lock: On or Off. · Record Lock: On or Off. 0150-0193C 58 Calibur DVMRe Triplex 4 Alarms 4.1 Alarm Input Alarm devices are connected via the Alarm PCB on the back panel of the unit (see section 1.7). Each Alarm Input corresponds with the Camera Input of the same number. Alarm input to camera number assignments can be changed on 10 and 16-channel models. See Alarm Action menu (section 3.11). 4.2 Alarm Output Front Panel Alarm LED: The LED located to the left and above the Alarm button is lit for the duration of the alarm. Internal Buzzer: The internal buzzer is activated until it is Silenced and Acknowledged. This feature can be turned off in the menu system (see Buzzer Setup in section 3.11). Monitor Displays: Discussed below in the On-screen Displays During Alarms section. Output Relays: The alarm output relays are active for the duration of the alarm. This feature is configured in the menu system (see Alarm Action and Relay Configuration in section 3.11) and can be deactivated. Macro Activation: Unit can be configured in the menu system to activate a macro when an alarm is detected. Preset PTZ Camera commands: Unit can be configured in the menu system to send preset commands to specific cameras when an alarm is detected. Record Rate: Record Rate can be increased by recording at the Alarm Record Rate (see section 3.10) and by Interleaved or Exclusive Recording (see Alarm Record mode in section 3.11). 4.3 Alarm Acknowledge Pressing the Alarm button acknowledges to the unit that the alarm has been recognized and silences the internal buzzer. This does not clear the alarm condition. 4.4 On-screen Displays During Alarms 10 and 16-Channel Units Monitor-A in Live Multiscreen Mode Single Alarm: When a single alarm is received, the unit changes to 4-way display containing the camera in alarm, and three associated cameras. The three associated cameras are defined as a group in the menu system (see Alarm Action in section 3.11). The top left cameo displays the camera in alarm. 4-Way Single Alarm Second Alarm: When a second alarm is received, the unit changes to a 10-way multiscreen, displaying the alarm cameras in the top two cameos. The associated cameras are displayed in the remaining cameos. 10-Way Second Alarm Third Alarm: When a third alarm is received, the unit changes to a 9-way multiscreen, displaying the alarm cameras in the top three cameos. The associated cameras are displayed in the remaining cameos. More than three alarms simultaneously: The unit switches to the maximum multiscreen display, i.e. 16 or 10-way. 9-Way Third Alarm 0150-0193C 59 Calibur DVMRe Triplex Other display options include: • A full screen display of a single camera in alarm, with a sequenced full screen display for additional cameras in alarm. This option is selectable in the menu system (see Full Screen Alarm in section 3.11). • Freeze camera display at the time the alarm was received. Monitor-B Display During Alarm Single Alarm: Unit switches to a full screen display of the camera in alarm. Additional Alarms: Unit switches to a sequenced display of all cameras in alarm. 4-Channel Units Single Alarm: Unit switches to a full screen display of the camera in alarm. Additional Alarms: Unit switches to a sequenced display of all cameras in alarm. 4.5 Alarm Operations During Playback Live Alarms Displays Single Alarm: Unit switc...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría