An instruction sheet displayed next to the machine is often helpful in notifying users that the appliance contains and dispense near-boiling water. In line with Health & Safety requirements we recommend that a risk assessment be carried out after the boiler has been installed. It is advisable to display a sign informing customers that drinks made from this boiler are very hot. During normal use of the boiler, certain surfaces will become hot. (especially near to the draw off tap). Care should be taken to avoid potential injury from burns and scalding whilst operating the appliance. Disclaimer. This appliance is designed to heat water. No other medium should be used. Glen Dimplex UK Ltd will not be held responsible for any accidents or injuries that occur from either misuse of the appliance or temperature of water or the hot drinks served. INTRODUCTION Your new water boiler is designed to give years of trouble free service provided that the instructions contained in this manual are followed carefully. Your new boiler is energy efficient, simple to operate and easy to service. It is recommended that the installation is carried out by a properly qualified fitter. CHECK LIST Before starting installation, check that you have the following parts: 1. Boiler Unit 2. Case 3. Mounting Template 4. Fitting Kit 5. Tap Kit (WB5E Only) INSTALLATION POSITIONING THE UNIT The heater should be positioned in a convenient place on a wall that is capable of supporting it safely. Use the mounting template and fitting kit provided. Position the boiler so that the tap is about 400mm above a draining board. Leave sufficient space around the unit to enable access for servicing, paying particular attention to the position of the top centre fixing screw that holds the cover in place. Screw in the top two screws leaving about 6mm protruding and hang the machine using the keyhole slots provided. Once the machine is positioned, tighten the top screws and insert the bottom screw. ELECTRICAL CONNECTION ALL MACHINES Supply – 220/240V 50Hz – 3kW. The circuit should be protected by its own 13amp double pole connection unit with flex outlet to BS5733, alternatively the circuit should have means of disconnection incorporated in fixed wiring, having a contact separation of at least 3mm in all poles. Minimum cable size is 1.5mm2. The use of an ELCB is recommended. Electrical installation should conform to current I.E.E. wiring regulations. When using fixed wiring, the bare section of earth wire must be sleeved to within 8mm of the end. Only a qualified electrician should carry out this work. WARNING: THIS APPLIANCE MUST BE EARTHED REAR ENTRY OF CABLE Fixed or flexible cable to be connected direct to the terminal block, cable gland not utilised. BOTTOM ENTRY OF CABLE Use the cable gland. Loosen cable-gripping nut. Pass cable through gland, leaving enough free cable to connect into the terminal block. Tighten cable gland grip nut. DO NOT SWITCH ON UNTIL THE INSTALLATION IS COMPLETE AND THE CASE AND TAP ARE IN PLACE WATER CONNECTION NOTE: Although it will not harm the boiler, it should not be operated with the water supply turned off. The water supply must have a pressure not exceeding 7 Bar (700kpa) and no lower than 1 Bar (200kpa). If the mains water pressure is below1 Bar a fault situation could arise as described in section; “Temperature Control and Safety cut-outs”.In addition the water inlet valve may not seat properly and can cause overflowing If your water pressure exceeds 7 Bar, a suitable pressure reduction valve will need to be fitted to the water supply to bring it to a level that the machine can cope with. Failure to do this could result in the boiler overfilling . The manufacturers cannot be held responsible for any machine malfunction if the water pressure exceeds that stated. If in doubt, consult your water supply company. The boiler has a type B air gap in compliance with water bylaws and has both WRAS and KIWA approval. Please note that washing machine hoses are not suitable for drinking water and will cause a very bad taste to the water. A 15mm stop valve should be fitted between the water supply and the boiler so that the machine can be isolated. Water purification filters are available to ensure fresh tasting water. Please contact the service department for details on 01704 502911. In hard water areas scale can cause problems. Fitting a scale reducer will help minimise scale. We regret that the manufacturers cannot be held responsible for scale problems even if a scale reducer has been installed. BOTTOM ENTRY Connect to a suitable cold drinking water supply using 15mm copper pipe and push on the ‘T’ piece supplied. The ‘T’ has been blanked off using a brass plug. Leave this plug in place. Push the ‘T’ p...
Otros modelos de este manual:Calentadores de Agua - WB15 (46.83 kb)
Calentadores de Agua - WB5E 1 (46.83 kb)
Calentadores de Agua - WB7 (46.83 kb)