Turning the dial counterclockwise increases temperature and clockwise reduces temperature. SETTING THE WATER HEATER TEMPERATURE AT 120°F (49°C) (APPROX. " " MARK ON FACE OF THERMOSTAT) WILL REDUCE THE RISK OF SCALDS. Some states require settings at specific lower temperatures. Figure 6 shows the approximate water temperatures produced at various thermostat dial settings. Short repeated heating cycles caused by small hot water uses can cause temperatures at the point of use to exceed the thermostat setting by up to 30°F (17°C). If you experience this type of use you should consider using lower temperature settings to reduce scald hazards. Valves for reducing point of use temperature by mixing cold and hot water are available. Also available are inexpensive devices that attach to faucets to limit hot water temperatures. Contact a licensed plumber or the local plumbing authority. Temperature Setting Time to Produce 2nd & 3rd Degree Burns on Adult Skin VERY HOT = APPROX.180°F (82°C) D = APROX. 160°F (71°C) C = APPROX.150°F (66°C) B = APPROX.140°F (60°C) A = APPROX.130°F (54°C) = APPROX.120°F (49°C) LOW = APPROX.100°F (38°C) Nearly instantaneous About 1/2 second About 1 1/2 seconds Less than 5 seconds About 30 secondsMore than 5 minutes - - - - - - - FIGURE 6 HIGH TEMPERATURE LIMIT SWITCH (Single-Use Type Energy Cut Off) The thermostat has a built-in limit switch which will extinguish the pilot light in case of excessive water temperatures. The pilot cannot be relit until the entire thermostat (labeled as single use type) is replaced. It is important that a serviceman be called to determine the reason for limit operation and thus avoid repeated thermostat replacement. Lower the temperature adjustment dial setting on new control. CHECKING VENTING The following steps shall be followed with each appliance connected to the venting system placed in operation, while any other appliances connected to the venting system are not in operation. 1. Seal any unused openings in the venting system. 2. Inspect the venting system for proper size and horizontal pitch, as required in the National Fuel Gas Code, ANSI Z223.1 or the CAN/CGA B149 Installation codes and these instructions. Determine that there is no blockage or restriction, leakage, corrosion and other deficiencies which could cause an unsafe condition. 3. So far as is practical, close all building doors and windows and all doors between the space in which the water heater(s) connected to the venting system are located and other spaces 11 of the building. Turn on all appliances not connected to the venting system. Turn on all exhaust fans, such as range hoods and bathroom exhausts, so they shall operate at maximum speed. Close fireplace dampers. 4. Follow the lighting instruction. Place the water heater being inspected in operation. Adjust thermostat so appliance shall operate continuously. 5. Test for draft hood spillage at the relief opening after 5 minutes of main burner operation. 6. After it has been determined that each appliance connected to the venting system properly vents when tested as outlined above, return doors, windows, exhaust fans, fireplace dampers and any other gas burning appliance to their previous conditions of use. 7. If improper venting is observed during any of the above tests, the venting system must be corrected. WARNING FAILURE TO CORRECT BACK DRAFTS MAY CAUSE AIR CONTAMINATION AND UNSAFE CONDITIONS. • If the back draft cannot be corrected by the normal method or if a suitable draft cannot be obtained, a blower type flue gas exhauster must be employed to assure proper venting and correct combustion. SERVICE INFORMATION The installer may be able to observe and correct certain problems which may arise when the unit is put into operation. HOWEVER, it is recommended that only qualified servicemen, using appropriate test equipment, be allowed to service the heater. FOR YOUR SAFETY AND SATISFACTORY OPERATION, IT IS RECOMMENDED THAT THIS HEATER BE CHECKED ONCE A YEAR BY A COMPETENT SERVICE PERSON. USERS OF THIS APPLIANCE SHOULD BE AWARE THAT GAS COMPONENTS WEAR OUT OVER A PERIOD OF TIME. THE GAS CARRYING COMPONENTS OF THIS APPLIANCE SHOULD BE INSPECTED FOR PROPER OPERATION PERIODICALLY BY A QUALIFIED SERVICE TECHNICIAN. PILOT AND MAIN BURNER Check pilot, figure 7, and main burner at least every 6 months for proper flame characteristics. The main burner should display the following characteristics: 1. Provide complete combustion of gas. 2. Cause rapid ignition and carryover of flame across entire burner. 3. Give reasonably quiet operation during ignition, burning and extinction. 4. Cause no excessive lifting of flames from burner ports. If preceding burner characteristics are not evident, check for accumulation of lint or other foreign material that restricts or blocks the air openings to the heater or burner. WARNING SOOT BUILD-UP INDICATES A PROBLEM THAT REQUIRES CORRECTION BEFORE FURTHER USE. CONSULT WITH A QUALIFIED SERVICE TECHNICIAN. Should th...
Otros modelos de este manual:Calentadores de Agua - BT- 65 (304.32 kb)
Calentadores de Agua - BT- 65 (304.32 kb)