Iniciar sesión:
Votos - 5, Puntuación media: 3.4 ( )

Manual de usuario Bradford-White Corp, modelo BTH-120 through BTH-500

Fabricar: Bradford-White Corp
Tamaño del archivo: 665.37 kb
Nombre del archivo: 569201b4-1400-4920-b95f-7420c52c882d.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Capacity F. 30 F. 40 F. 50 F. 60 F. 70 F. 80 F. 90 F. 100 F. 110 F. 120 F. 130 F. 140 F. BTUH KW C. 17 C. 22 C. 28 C. 33 C. 39 C. 44 C. 50 C. 56 C. 61 C. 67 C. 72 C. 78 C. BTH 120 NATURAL/ PROPANE 120,000 95% 60 U.S. Gal GPH 461 345 276 230 197 173 154 138 126 115 106 99 35 227 Litres LPH 1744 1308 1046 872 747 654 581 523 476 436 402 374 BTH 150 NATURAL/ PROPANE 150,000 95% 100 U.S. Gals. GPH 576 432 345 288 247 216 192 173 157 144 133 123 44 379 Litres LPH 2179 1635 1308 1090 934 817 726 654 594 545 503 467 BTH 199 NATURAL/ PROPANE 199,900 95% 100 U.S. Gals. GPH 767 575 460 384 329 288 256 230 209 192 177 164 58 379 Litres LPH 2904 2178 1743 1452 1245 1089 968 871 792 726 670 622 BTH 250 NATURAL/ PROPANE 250,000 73 95% 100 U.S. Gals. GPH 960 720 576 480 411 360 320 288 262 240 221 206 379 Litres LPH 3632 2724 2179 1816 1557 1362 1211 1044 991 908 838 778 BTH 300 NATURAL/ PROPANE 300,000 96% 130 U.S. Gals. GPH 1164 873 699 582 499 436 388 349 318 291 269 250 88 492 Litres LPH 4406 3304 2644 2203 1888 1652 1469 1322 1201 1102 1017 945 BTH 400 NATURAL/ PROPANE 399,900 96% 130 U.S. Gals. GPH 1552 1164 931 776 665 582 517 465 423 388 359 332 117 492 Litres LPH 5875 4406 3525 2938 2518 2203 1958 1759 1602 1469 1356 1259 BTH 500 NATURAL/ PROPANE 499,900 95% 130 U.S. Gals. GPH 1919 1439 1151 959 822 720 640 576 523 480 443 411 146 492 Litres LPH 7263 5447 4358 3631 3113 2724 2421 2179 1981 1816 1676 1556 Recovery capacities are based on heater performance at 95% and 96% thermal efficiency. Add "A" to model number when ordering ASME. Optional on 120 - 250 models. Standard on 300 - 500 models. Maximum gas supply pressure for 120 - 250: 10.5" w.c. natural gas 14" w.c propane. Maximum gas supply pressure for 300-500 10" w.c. natural gas 13" w.c. propane. Manifold pressure: 4" w.c. natural gas 10" w.c. propane. Electrical requirements: 120 VAC, Blower 2.2 Amps FL, Igniter 4.0 Amps. SUGGESTED SPECIFICATION (Natural or Propane) gas water heater(s) shall be A. O. Smith Cyclone Xi model # _________ or equal, with up to 96% thermal efficiency, a storage capacity of ______ gallons, an input rating of __________ BTUs per hour, a recovery rating of ___________ gallons per hour (gph) at 100° F rise and a maximum hydrostatic working pressure of 160 PSI. Water heater(s) shall: 1. Have seamless glass-lined steel tank construction, with glass lining applied to all water-side surfaces after the tank has been assembled and welded; 2. Have a spiral-shaped heat exchanger placed entirely inside the tank, which shall be glass-lined to protect against acidic flue gas condensate; 3. Have foam insulation and an ASME-rated temperature and pressure relief valve; 4. Have a down-fired power burner designed for precise mixing of air and gas for optimum efficiency, requiring no special calibration on start-up; 5. Be approved for 0. clearance to combustibles. Heater shall be supplied with maintenance-free powered anode. The control shall be an integrated solid-state temperature and ignition control device with integral diagnostics, graphic user interface, fault history display, and shall have digital temperature readout. The water heater(s) shall: 1. Be design-certified by UL (Underwriters Laboratories), according to ANSZ21.10 standards governing storage-type water heaters; 2. Meet ASHRAE/IESNA 90.1-1999; 3. Be design-certified by Underwriters Laboratories for 180° F (62° C) water; 4. Meet SCAQMD Rule 1146.2 for low-NOx emissions. For conventional-vent specification: The BTH-120 - 250 water heater(s) shall be suitable for venting in 3. PVC pipe for a total equivalent distance of 50 ft and 4. PVC pipe for a total equivalent distance of 120 ft. The BTH-300 - 500 water heater(s) shall be suitable for venting only in 4. PVC pipe, for a total equivalent distance of 70 ft. For sealed-combustion direct-vent specification: The BTH-120 - 250 water heater(s) shall be suitable for venting with (3. or 4.) _______ diameter PVC pipe for a total equivalent distance of (50 ft or 120 ft) ________ feet. [Alternative venting: the heater(s) shall be suitable for sealed combustion direct venting using a (3. or 4.) ________ diameter PVC exhaust pipe for a total distance of (50 ft or 120 ft) ________ equivalent feet of vent and (50 ft or 120 ft) _______ equivalent feet of intake.] The BTH-300 - 500 water heater(s) shall be suitable for sealed combustion direct-vent using only 4. diameter PVC pipe and 4. diameter PVC exhaust pipe for a total equivalent distance of 70 ft. Operation of the water heater(s) in a closed system where thermal expansion has not been compensated for (with a properly sized thermal expansion tank) will void the warranty. For Technical Information and Automated Fax Service, call 800-527-1953. A. O. Smith reserves the right to make product changes or improvements without prior notice. Page 4 of 4 ACGSS02407 Dec...

Otros modelos de este manual:
Calentadores de Agua - BTH-120 through BTH-500 (665.37 kb)
Calentadores de Agua - BTH-120 through BTH-500 (665.37 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría