Manual de usuario Raypak, modelo B6000

Fabricar: Raypak
Tamaño del archivo: 1.37 mb
Nombre del archivo: 0514ef00-f16c-4803-8e48-6cc30e55c023.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


® is a registered trademark of UnderWriters Laboratories-Canada Inc.® Before operating this product, please read these instructions completely. Page 2 B6000 BOILER MANAGEMENT SYSTEM (BMS) Contents Equipment Quantity B6000 System Control B6000 Boiler Monitor, Installed on Boiler(s) Outdoor Temperature Sensor Assy. (064140) Water Temperature Sensor Assy. (064139) Optional Equipment 1 As Ordered 1 1 As Ordered Check packaging for damage or missing components. IMPORTANT NOTICE: These instructions are intended for the use by qualified personnel only, specifically trained and experienced in the installation of this type of equipment and related system components. Installation and service personnel may be required by some states to be licensed. If your state is such, be sure your contractor bears the appropriate license. Only qualified persons shall attempt to repair this equipment. Repair must be according to these instructions. WARNING: Improper installation, adjustment, alteration, service or maintenance may damage the equipment, create a hazard resulting in asphyxiation, explosion, fire, electric shock, personal injury or property damage and will void the warranty. CAUTION: MORE THAN ONE (1) SUPPLY SOURCE. THIS CONTROL HAS THE POTENTIAL TO BE CONNECTED TO MORE THAN ONE (1) ELECTRICAL SUPPLY SOURCE. TO REDUCE THE RISK OF ELECTRIC SHOCK, DISCONNECT ALL CONNECTIONS BEFORE SERVICING. CAUTION: RISK OF ELECTRIC SHOCK. MORE THAN ONE (1) DISCONNECT SWITCH MAY BE REQUIRED TO DE-ENERGIZE THE EQUIPMENT BEFORE SERVICING. PLEASE REGISTER Before proceeding any further, please take a moment to complete the enclosed user registration form and mail to Raypak, Inc., 2151 Eastman Avenue, Oxnard, CA 93030. Page 3 TABLE OF CONTENTS PAGE Contents 3 Getting Started 5 Foreword 5 Installation and Mounting 7 Mechanical Installation 7 Electrical Installation 8 Check Your Power Source 8 Air Temperature Sensor 9 Water Temperature Sensor 10 Important Configuration Note 12 Wiring - Air and Water Sensors 12 Communication (RS485) Wiring 13 Wiring: Power Source to Control and Boiler Modules 14 Power Test 15 Boiler Monitor Select Switch 16 Boiler Monitor Communications Jumper W1 17 Optional Boiler Monitor Control 18 Field Wiring - Single Boiler 18 Field Wiring - Multiple Boilers 19 Installation Verification Procedure 20 System Control/Display Familiarization 21 Power Up - Boiler Monitor 22 Power Up - System Control Module 23 Displays 23 Important (Start Alternate) 35 System Control Box 39 System Control Board Pictorial 40 Replacement Parts List 42 Boiler Monitor Control Box 44 System Settings 46 Troubleshooting Guide 47 Page 4 Thank you for selecting the Raypak B6000 Boiler Management System (BMS). It is our sincere hope that you will enjoy its power, ease of use and energy saving features. GETTING STARTED To learn about the B6000 BMS, simply install it and start using it. The following steps will outline the things you will need for installation and to prepare it for use. FOREWORD The B6000 Boiler Management System is comprised of a Boiler Monitor for each boiler, one System Control for each system, an Outdoor Air Temperature Sensor and a Water Temperature Sensor. The system is a microprocessor-based energy management hot water control system that controls single or multiple boiler installations used for hydronic heating and/or domestic hot water supply. The B6000 BMS is designed to provide the ultimate in personal comfort, efficiency and operation. The system requires minimal attention after initial setup. The system control to boiler can be separated by up to 2000 feet. It is capable of being monitored from a remote location, with an optional modem package and a Personal Computer (PC) equipped with a modem. The Raypak Boiler Management System minimizes boiler operator attendance and increases system reliability and cost effectiveness. The System Control Module has • A screen that displays the different operating characteristics of the system. • A green light, to the left of the screen, that indicates normal system operating conditions. • A red light, to the right of the screen, that flashes when a fault occurs. • An alarm buzzer with a silencing switch. If the buzzer is silenced the red light will continue to flash until the diagnosed fault is corrected. • Buttons which are used to monitor and program the selectable system features. • On board relays designed to control primary system pumps, combustion vent louvers and/or other boiler accessories. Page 5 Each Boiler Monitor Module contains • The boiler on-off power switch. • The boiler manual override switch, which allows the boiler to operate independently in the event of asystem control failure. • Standard indicator lights: "Power On" - green, indicates the boiler is powered. "Manual Override" - red, indicates boiler is in manual override mode. "Call for Heat" - amber, indicates there is a call for heat. "Pump" - green, indicates pump circuit is energized. "High Limit" - red, indicates boi...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría