Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Cleveland Range, modelo GFB-15

Fabricar: Cleveland Range
Tamaño del archivo: 132.06 kb
Nombre del archivo: c196dfbd-7bc7-4b38-8b77-5770390f634b.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Code ¦ Registered with the National Board of Boiler & Pressure Vessel Inspectors ¦ Accepted for use in U.S.D.A. Inspected Facilities Options & Accessories . Stainless Steel outer Jacket . Automatic Boiler Blow-down Controls . Applicable Controls to meet the various special insurance, local, state or federal code requirements . Electric heated Steam Boilers . Oil-fired Steam Boilers . Cooling Kit for boiler drain . Aquastat automatic drain cooling kit . Larger models availabe on request ShallbeCLEVELANDModelGFB-____,gas-fired,vertical,tube- lessLARGESTEAMBOILERSystem,_____H.P.(horsepower); CompletewithPowerBurners;SkidmountedandpipedwithVerticalCondensateReturnSystemandBlow-DownSeparatorPackage;Factoryassembledasaself-containedunit,inaccor- dancetoU.L.requirements,andA.S.M.E.Section1(one)Code; Guaranteedproductionof_______poundsofSteamperhourat212°F. ShortFormSpecifications SECT. XIV PAGE 53 1333 East 179 St., Tel: 1-216-481-4900 Web Site: Cleveland, Ohio, U.S.A. 44110 Fax: 1-216-481-3782 Email: Steam@ClevelandRange.com SECT. XIV PAGE 54 0907 Cleveland Range reserves right of design improvement or modification, as warranted. Litho in USA F H CAN PIVOT 360. GAS HEAD E (TO OUTSIDE 1-1/4" DIA. VENT 3" DIA. VENT (TO OUTSIDE OF BUILDING) G C D 4 1/4" B (PIPE TO DRAIN) OVERFLOW OVERALL REMOVAL BURNER SAFETY VALVE EXHAUST 4 1/4" STEAM GAGE ASSEMBLY A BOILER HEIGHT WITH TRIM (NOT SUPPLIED) SHUTOFF VALVE GAS INLET GAS INLET OF BUILDING) FRONT VIEW PLAN VIEW 2 1 2 CR D MINIMUM CLEARANCE FRONT 18" SIDES 18" REAR 18" TOP - see dimension "C" DIMENSIONS MODEL A B C D E F G H GFB-6 75" 72" 86 1/4" 56 1/4" 48" 33" 44" 22 1/2" GFB-10 80 1/2" 78" 90 1/4" 62 1/4" 54" 33 1/2" 46" 21 1/2" GFB-15 86 1/2" 84" 96 1/4" 67 1/4" 54" 35 1/2" 47" 20 1/2" GFB-20 92 1/2" 90" 100 1/4" 70 1/4" 54" 43" 60" 25" GFB-30 102" 96" 110 1/4" 77 3/4" 60" 49" 67" 27" GFB-50 106 1/2" 114" 118 1/4" 83 1/4" 66" 57" 78" 22 1/2" GFB-60 120" 114" 128 1/4" 89 1/4" 66" 57" 78" 34" UTILITY CONNECTIONS 120 / 1 PH BOILER BLOW DOWN STEAM CONDEN NATURAL GAS EL1 EL2 FILL COLD OUTPUT -SATE BLOWDOWN CONSUMPTION ELEC- FOR MODEL COLD WATER WATER STEAM LBS/HR RETURN DRAIN GAS FT3/HR TRICAL PUMP GFB-6 1/2" NPT 1" NPT 3/4" 207 1" 1 1/2" 1" 260 5.2 10 NPT NPT NPT NPT AMPS AMPS GFB-10 1/2" NPT 1" NPT 1" 345 1 1/4" 1 1/2" 1" 420 5.2 10 NPT NPT NPT NPT AMPS AMPS GFB-15 1/2" NPT 1 1/4" NPT 1 1/4" 518 1 1/4" 1 1/2" 1 1/4" 630 5.2 15 NPT NPT NPT NPT AMPS AMPS GFB-20 1/2" NPT 1 1/4" NPT 1 1/2" 690 1 1/4" 1 1/2" 1 1/4" 840 9.2 15 NPT NPT NPT NPT AMPS AMPS GFB-30 1/2" NPT 1 1/4" NPT 2" 1035 1 1/4" 1 1/2" 1 1/2" 1260 9.2 20 NPT NPT NPT NPT AMPS AMPS GFB-50 3/4" NPT 1 1/2" NPT 3" 1725 2" 1 1/2" 1 1/2" 2100 **4.4 **11 NPT NPT NPT NPT AMPS AMPS GFB-60 3/4" NPT 2" NPT 3" 2070 2" 1 1/2" 2" 2520 **4.4 **16.7 NPT NPT NPT NPT AMPS AMPS ** 208V / 3PH DD 1 1 DD 2 2 D 1 D 2 D 1BB DD 1 2 B D 2 B B D 1 D 2 1 2 (NOT TO SCALE) 2 D 1 D 2 B 1 NOTE: It is the owners/operators responsiblity to meet the recommended mi...

Otros modelos de este manual:
Calentadores de Agua - GFB-6 (132.06 kb)
Calentadores de Agua - GFB-60 (132.06 kb)
Calentadores de Agua - GFB-10 (132.06 kb)
Calentadores de Agua - GFB-20 (132.06 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría