Manual de usuario Burnham, modelo Hydronics C4

Fabricar: Burnham
Tamaño del archivo: 743.23 kb
Nombre del archivo: 881af686-6e7e-49e4-a2f5-7d9ab012ddc7.pdf

Idioma del manual:en

El documento se está cargando, por favor, espere
El documento se está cargando, por favor, espere

Resumen del manual


They are impervious to petroleum-based chemicals, which can deteriorate gaskets used in some competitors’ boilers. Ease of Maintenance and Installation The C3 & C4 Series Boilers are designed for quick, inexpensive servicing. Jacket design allows entry from both the top and side to allow complete access for cleaning. Burner swing door provides easy access to the combustion chamber for fast servicing. Packaged and ready to install with optional tankless coil for domestic hot water. Circulator is prepiped and wired for on the spot installation. C3 & C4 RATINGS BOILER MODEL (1) BURNER CAPACITY GPH (2) DOE HEATING CAPACITY MBH (3) I=B=R NET RATINGS MBH (4) MINIMUMCHIMNEY REQUIREMENTS AFUE % ROUND IN DIAMETER RECTANGLE IN. x IN. HEIGHT (FT.) C3 0.75 89 77 6 8 x 8 15 83.5 C4 1.20 140 121 6 8 x 8 15 81.7 Notes: 1. Available as a packaged water boiler only. 2. The Burner Capacity is based on oil having a heating value of 140,000 BTU/GAL. 3. DOE Heating Capacity and Annual Fuel Utilization Efficiency (AFUE) are based on U.S. Government tests at 13.0% CO2 with No. 1 maximum smoke and -0.02 inches water column over fire draft on standard equipment package. 4. Net I=B selecting boiler. Maximum Working Pressure: 30 PSI water. C3 & C4 DIMENSIONS AMD STANDARD EQUIPMENT Boiler Model A B C C3 16" 8-3/4" 6" C4 20" 10-3/4" 6" Standard Equipment: • Cast Iron Section Assembly • Deluxe Insulated Jacket • Burner Swing Door & Mounting Plate Beckett • Flame Retention Burner • Boiler Drain Valve • Barometric Draft Regulator 14000 Volt Electric Ignitor • Solenoid Oil Valve • 1-1/2" Supply Connection • Relief Valve • Combination High Limit Circulator Relay Control • Pressure/Temperature Gauge • Protectorelay Control Circulator OPTIONAL TANKLESS HEATERS OPTIONAL TANKLESS HEATERS BOILER MODEL HEATER MODEL HEATER GPM OUTPUT (1) C3 V1-2 3.25 C4 V1-1 3.5 Notes: 1. Tankless heater rating G.P.M. based on 100°F rise with 40°F inlet water (intermittent draw) with boiler water temperature of 200° F. Other Optional Equipment: • Two stage fuel unit LIFETIME LIMITED WARRANTY Every C3 & C4 cast iron heat exchanger is covered by Burnham's Lifetime True Blue Limited Warranty. H Burnham Hydronics Form No. PL81401271001-6/05-.3Mw Printed in the U.S.A. ©2005 U.S. Boiler Company, Inc. - Lancaster,PA Phone: 717-397-4701 www.burnham.com...

Otros modelos de este manual:
Calentadores de Agua - Hydronics C3 (743.23 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría