Iniciar sesión:
Votos - 2, Puntuación media: 4 ( )

Manual de usuario Weil-McLain, modelo CGs

Fabricar: Weil-McLain
Tamaño del archivo: 1.8 mb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


"B" in the safety information above. If you don't smell gas, go to the next step. 5. When equipped with Johnson Controls vent damper Model M35, manually rotate damper blade in direction of arrow to Open position indicated on damper assembly. 10. Move selector arm to ON. 6. This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot 11. Turn on all electric power to the appliance. by hand. 7. Depress and move selector arm to OFF. Note: Selector 12. When equipped with Effikal vent damper, place service arm cannot be moved to OFF unless selector arm is switch in Automatic Operation position. depressed slightly. Do not force. 13. Set thermostat to desired setting. Selector 14. If the appliance will not operate, follow the instructions arm ToTurn Off Gas To The Appliance and call your service technician or gas supplier. 15. Replace front panel. Position indicator (shown in position)OFF 59332 TOTURN OFF GAS TOTHE APPLIANCE 1. Set the thermostat to lowest setting. 4. Depress and move selector arm to OFF. Do not force. 2. Turn off all electric power to the appliance if service is to 5. Replace front panel. be performed. 3. Remove front panel. Part Number 550-110-592/1000 CGa, CGi, CGs, EG, EGH, LGB, PEG, PFG Boiler. Operating instructions EGH-85 to EGH-125, • Spark-ignited pilot PFG-6 to PFG-8 • Gas valve — Robertshaw 7000DERHC FOR YOUR SAFETY READ BEFORE LIGHTING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance is equipped with an ignition C. Use only your hand to turn the gas control knob. Never use tools. If device which automatically lights the pilot. Do the selector arm will not depress or move by hand, don't try to repair not try to light the pilot by hand. it, call a qualified service technician. Force or attempted repair may result in a fire or explosion. B. Before OPERATING, smell all around the appliance area for gas. Be sure to smell next to D. Do not use this appliance if any part has been under water. the floor because some gas is heavier than air and Immediately call a qualified service technician to inspect the appliance will settle on the floor. See below. and to replace any part of the control system and any gas control, which has been under water. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Immediately call your gas supplier from a neighbor’s phone. Follow the gas supplier’s instructions. • Do not touch any electric switch; do not use any phone in your building. • If you cannot reach your gas supplier, call the fire department. OPERATING INSTRUCTIONS 1. Stop! Read the safety information above on this label. 2. Set the thermostat to lowest setting. 3. When equipped with Effikal vent damper Model RVGP, place service switch in Hold Damper Open position. 4. Turn off all electrical power to the appliance. Gas control knob (shown in ON position) 5. When equipped with Johnson Controls vent damper Model M35, manually rotate damper blade in direction of arrow to Open position indicated on damper assembly. Position 6. Turn gas control knob clockwise to OFF. 59205b indicator 7. When equipped with vent damper, verify damper blade is in full open position. 8. Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow "B" in the safety information above. If you don't smell gas, go to the next step. 9. Turn gas control knob counterclockwise to PILOT. 10. Turn on all electric power to the appliance. 11. When equipped with Effikal vent damper, place service switch in Automatic Operation position. 12. Set thermostat to desired setting. 13. If the appliance will not operate, follow the instructions "TO TURN OFF GAS TO APPLIANCE" below and call your service technician or gas supplier. 14. Replace front panel. TOTURN OFF GAS TOTHE APPLIANCE 1. Set the thermostat to lowest setting. 3. Remove front panel. 2. Turn off all electric power to the appliance if service is to 4. Turn gas control knob clockwise to OFF. be performed. 5. Replace front panel. Part Number 550-110-592/1000 Gas control knob (shown in "ON" position) User.s Information Manua. Operating instructions CGi, CGs • Spark-ignited pilot • Gas valve — Honeywell VR8204/VR8304, White-Rodgers 36C and 36E FOR YOUR SAFETY READ BEFORE OPERATING If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life. A. This appliance does not have a pilot. It is equipped C. Use only your hand to turn the gas control knob. Never use with an ignition device which automatically lights tools. If the knob will not turn by hand, don't try to repair it, the burner. Do not try to light the burner by hand. call a qualified service technician. Force or attempted repair may result in a fire or explosion. B. Before OPERATING, smell all around the appliance area for gas...

Otros modelos de este manual:
Calentadores de Agua - CGi (1.8 mb)
Calentadores de Agua - EGH (1.8 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría