If hydrogen is present, an unusual sound – such as air escaping – will come from the open faucet as the hot water begins to flow. Hydrogen gas is extremely flammable – there must be no open flame near this open faucet. Bock Water Heaters, Inc. 110 S. Dickinson St. • P.O. Box 8632 • Madison, WI 53708-8632 Phone: 608/257-2225 • Fax: 608/257-5304 • SPECIFICATIONS Leave ample room for servicing when the water heater is installed – do not block access to the burner, inspection door, handholes or controls. Leave room to pipe the unit and connect the fuel and electricity. BURNER SPECIFICATIONS Bock Multi- Flue Series 150-400 150-600 150-800 200-450 200-650 200-850 200-1150 250-800 250-1000 250-1250 250-1500 Nominal Storage 176 gal. 168 gal. 160 gal. 221 gal. 212 gal. 204 gal. 192 gal. 273 gal. 260 gal. 251 gal. 242 gal. Stack Size, in. 8 in. 8 in. 10 in. 8 in. 8 in. 10 in. 12 in. 10 in. 12 in. 14 in. 14 in. Turboflues, Qt. 3 5 7 3 5 7 10 7 10 12 14 Anode Rods, Qt. 4 4 6 4 4 6 10 6 8 10 11 Bock Oil Fired Model 150E-400 150E-600 150E-800 200E-450 200E-650 200E-850 200E-1150 250E-800 250E-1000 250E-1250 250E-1500 Max. Fire Rate 3.0 gph 4.5 gph 6.0 gph 3.2 gph 4.6 gph 6.1 gph 8.2 gph 6.0 gph 7.1 gph 9.0gph 11.0 gph Btu/hr input 400000 600000 800000 450000 650000 850000 1150000 800000 1000000 “1,250,000” 1500000 Burner Make Wayne Wayne Wayne Wayne Wayne Wayne Wayne Wayne Wayne Wayne PowerFlame Model EH EH EH EH EH EH FH EH FH FH C2-OAS Nozzle 3.0 x 80A 4.5 x 80B 5.5 x 80A 3.0 x 80B 4.5 x 80B 6.0 x 70B 2-4.0 x 80B 6.0 x 70B 2-3.5 x 80B 2-4.5 x 80B 6.00x70B* OEM Number 371-026B 371-028 193-020 371-028 371-028 193-020 193-022 193-020 193-022 193-022 Burner Make Carlin Carlin Carlin Carlin Carlin Carlin Carlin Model 201 CRD 301 CRD 301 CRD 201 CRD 301 CRD 301 CRD 301 CRD Nozzle 2.5 x 70B* 4.0 x 80B* 5.0 x 80A or 70W* 2.5 x 70B* 4.0 x 80B* 5.0 x 80A or 70W* 5.0 x 80A or 70W* OEM Number 9828500B361E 9859400B 9859400B 9828500B361E 9859400B 9859400B 9859400B Bock Dual Fuel Model 150DF-400 150DF-600 150DF-800 200DF-450 200DF-650 200DF-850 200DF-1150 250DF-800 250DF-1000 250DF-1250 250DF-1500 Max. Fire Rate 3.0 gph 4.5 gph 6.0 gph 3.2 gph 4.6 gph 6.1 gph 8.2 gph 6.0 gph 7.1 gph 9.0 gph 11.0 gph Btu/hr input 400000 600000 800000 450000 650000 850000 1150000 800000 1000000 1,250,000 1500000 Burner Make Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Model C1-GO-10 C1-GO-10 C1-GO-10 C1-GO-10 C1-GO-10 C1-GO-10 C1-GO-12 C1-GO-10 C1-GO-12 C1-GO-12 C2-GO-15 Nozzle 1.65x70B* 2.50x70B* 3.25x70B* 1.75x80B* 2.50x70B* 3.5x70B* 4.50x70B* 3.25x70B* 4.0x70B* 5.00x70B* 6.00x70B* Bock Power Gas Model 150G-400 150G-600 150G-800 200G-450 200G-650 200G-850 200G-1150* 250G-800 250G-1000 250G-1250* 250G-1500 Btu/hr input 400000 600000 800000 450000 650000 850000 1150000 800000 1000000 “1,250,000” 1500000 Burner Make Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Power Flame Model J15A-10 J15A-10 J30A-10 J15A-10 J15A-10 J30A-10 J30A-12 J30A-10 J30A-10 J30A-12 C2-G-15 Burner Controls: Burner Primary Control Detector Wayne EH R8184G 1294 C554A PF C2-0AS RM7895C 1012 C7072A PF C1-GO-10,12,15 RM7895C 1012 C7072A CARLIN 201CCRD, 301CRD P/N 4020002 C1440700K Aquastats: High Limit Honeywell Model L4080 & Averaging Control Model L8100C. Flue Tubes: Flue tubes constructed of steel minimum, 1/8 in. thick, 6 in. OD by 35 in. long, and provided with fins welded in a spiral pattern. Model Number of Flues 150-400 3 200-450 3 150-600 5 200-650 5 150-800 7 200-850 7 200-1150 10 250-1250 12 250-1500 14 WARNING WARNING CAUTION WATER PIPING GAS PIPING OIL PIPING MOUNTING THE BURNER CONNECT TO THE CHIMNEY Improper installation, adjustment, alteration, service or maintenance can cause serious injury or property damage. Refer to this manual. For assistance or additional information, consult a qualified installer or service agency. If the information in these instructions is not followed exactly, fire or explosion may result and can cause property damage, personal injury or death. Do not install on combustible flooring. Minimum clearance to combustible construction is: SIDES: 6”; BACK: 6”; FRONT: 24”. Install in accordance with all local codes. In the absence of local codes, refer to National Fuel Gas Code and/or NFPA 31 or ANSI Z21.10.1. Install unions and shut-off valves on both hot and cold water lines. A temperature and pressure (T&P) relief valve has been installed at the factory. Install a discharge line from the relief valve outlet to a suitable drain. Arrange the line without restriction to allow for complete drainage of both the relief valve and line. Do not install a check valve in the cold water line. If backflow preventers or pressure regulators are installed, be sure to make provision for expansion of water when heated by installing either a thermal expansion valve or an expansion t...
Otros modelos de este manual:Calentadores de Agua - 150 (77.25 kb)
Calentadores de Agua - 250 (77.25 kb)