|
Resumen del manual
Concentric Diameter (mm) 80/125 100/150 100/150 100/150 130/200 130/200 Max. length (m) 40 40 40 15 15 15 Max. 45/90° bends 7 7 7 4 3 3 Parallel (standard diameter) Diameter (mm) 80 100 100 100 130 130 Max. length (m) 25 80 45 25 115 60 Lequivalent/bend 90° (m) 3,9 4,6 4,6 4,6 2,4 2,4 Lequivalent/bend 45. (m) 1,1 1,2 1,2 1,2 1,4 1,4 Parallel (larger diameter for more length) Diameter (mm) 100 130 130 130 150 150 Max. length (m) 100 100 100 100 100 100 Lequivalent/bend 90. (m) 4,6 2,4 2,4 2,4 2,6 2,6 Lequivalent/bend 45. (m) 1,2 1,4 1,4 1,4 1,6 1,6 * All Cyclone BFC are also approved for installations where the unit is supplied without venting materials (C63). Concentric flues It is not permitted to use more than the specified number of bends, even when the duct is shorter than the maximum length. A 45° bend is equivalent to a 90° bend. Parallel flues - The maximum permissible length should be reduced by the equivalent length of each bend. (Note: for a parallel installation this means that 3 changes in direction amount to 6 bends (3 in the supply duct and 3 in the flue). - The maximum length also applies if a parallel installation has different supply and flue duct lengths (B23, C53). - Combined flues (C43) shall be fitted with a condensate drain. Note: horizontal flue runs must be installed with a fall of at least 5 mm per metre. Flue systems Cyclone BFC Minimum space requirements BFC 28 BFC 30 BFC 50 BFC 60 BFC 80 BFC 100 Minimal space for wall duct (mm) V 550 550 550 550 640 640 W 725 790 790 790 940 940 X 1535 2075 2075 2075 2230 2230 Y 1460 1480 1480 1480 1620 1620 Y * 1010 1030 1030 1030 1170 1170 Minimal space for roof duct (mm) V 1305 1500 1500 1500 1730 1730 W 680 1035 1035 1035 1120 1120 X 2965 3325 3325 3325 3620 3620 X ** 2015 2375 2375 2375 2670 2670 Y 1575 1415 1415 1415 1560 1560 Y ** 625 465 465 465 610 610 For the parts numbers of components and flue gas ducts, etc. please refer to the “Maintenance and accessories” chapter. O80/125 O100/150 O100/150 O100/150 O130/200 O130/200 * Distance without concentric pipe between bend and wall duct. ** Distance without concentric pipe between appliance and roof duct. BFC 28-60 BFC 80-100 BFC 28 BFC 30 BFC 50 BFC 60 BFC 80 BFC 100 ...
Otros modelos de este manual:Calentadores de Agua - BFC - 100 (826.55 kb)
Calentadores de Agua - BFC - 100 (826.55 kb)
Calentadores de Agua - BFC - 100 (826.55 kb)
Calentadores de Agua - BFC - 28 (826.55 kb)