Iniciar sesión:
Votos - 2, Puntuación media: 5 ( )

Manual de usuario Heatmaster, modelo HM 71

Fabricar: Heatmaster
Tamaño del archivo: 138.83 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Combustion gas circuit The combustion gas circuit is paint protected and comprises: • Flue pipes HeatMaster 71/101 models contain 8 steel flue pipes with an internal diameter of 64 mm. Each pipe is fitted with a turbulator of stainless steel designed to improve heat exchange and to reduce flue gas temperature. • Combustion chamber The combustion chamber on HeatMaster models is entirely water cooled. Insulation The boiler body is fully insulated by rigid polyurethane foam with a high thermal insulation coefficient, sprayed on without the use of CFCs. Casing The boiler is covered by a steel casing which has been scoured and phosphated before being stove enamelled at 220 °C. Burner 71 and 101 models are always delivered with ACV BG 2000-M 71 and 101 air/gas premix burners. DESCRIPTION Top cover Flue reduction collar Automatic air vent Central heating flow pipe Flue pipes and turbulators Insulation Burner Heating return Combustion chamber Burner chamber plate Primary circuit Casing front panel Primary expansion vessel Domestic cold water inlet Heating circuit filling valve with removable hose and non-return valve Primary shunt pump Domestic hot water outlet Tank-in-Tank heat exchanger Detector NTC1 and NTC2 Detector NTC3 Low water pressure switch Primary safety valve TECHNICAL SPECIFICATION DIMENSIONS The units are delivered fully assembled, tested and packed on a timber base with shockproof edges and protected by heat-shrunk plastic film. On delivery and after unpacking, check the equipment for damage. For transport purposes, refer to the weights and dimensions given below. G D F E J HBAK C C/2 A mm B mm C mm D mm E mm F mm G O mm H mm J mm K mm HM 71 1743 1630 680 937 680 390 150 1289 285 1720 HM 101 2093 2030 680 937 680 390 150 1693 285 2120 GENERAL FEATURES HM 71 HM 101 Fuel type Natural gas / propane Natural gas / propane Maximum Input kW 20 - 69.9 25 - 107 / 22 - 110 Maximum Output kW 63.0 96.8 Maintenance loss at 60 °C of rated value % 0.5 0.4 Total capacity L 239.0 330.0 Primary circuit capacity L 108.0 130.0 Hot water connection O 1” 1” Heating connection O 11/2” 11/2” Flue connection O mm 150 150 Hot water tank heat exchange surface m2 3.14 3.95 Weight empty Kg 282 335 Pressure drop primary circuit mbar 46 83 TECHNICAL SPECIFICATION MAXIMUM OPERATING CONDITIONS Maximum service pressure (tank full of water) - Primary circuit: 3 bar - Secondary circuit: 10 bar Test pressure (tank full of water) - Primary circuit: 4.5 bar - Secondary circuit: 13 bar Operating temperature Maximum temperature: 90 °C Water quality • Chlorures: < 150 mg/l (304) < 2000 mg/l (Duplex) • 6 . ph . 8 DOMESTIC HOT WATER PERFORMANCES HM 71 HM 101 Peak delivery at 40 °C L/10’ 646 905 Peak delivery at 45 °C L/10’ 543 777 Peak delivery at 60 °C L/10’ 346 514 Peak delivery at 70 °C L/10’ 268 385 Peak delivery at 80 °C L/10’ 203 290 Peak delivery at 40 °C L/60’ 2133 3172 Peak delivery at 45 °C L/60’ 1794 2680 Peak delivery at 60 °C L/60’ 1219 1813 Peak delivery at 70 °C L/60’ 971 1378 Peak delivery at 80 °C L/60’ 710 1003 Continuous delivery at 40 °C L/60’ 1835 2776 Continuous delivery at 45 °C L/60’ 1573 2379 Continuous delivery at 60 °C L/60’ 1067 1665 Continuous delivery at 70 °C L/60’ 715 1241 Continuous delivery at 80 °C L/60’ 675 903 Reheat time to 60 °C min 16 13 HEATMASTER CONTROL SETTINGS Description The 71/101 series is fitted with an electronic controller (MCBA) which controls burner operation (ignition, safety and modulation), and provides facilities to adapt the controller to the desired application. The MCBA has three levels of settings : manufacturer, installer and user. There are three temperature detectors located in the primary and secondary circuits. It provides two operating modes. 1. Heating mode Temperature set by the user at between 60 and 90 °C. • Differential “ON”, burner starts. • Differential “OFF”, burner stops. • PI (Proportionnel Integral) regulator in “heating” mode. • The regulator compares the primary temperature with the setting and modulates. The room thermostat detects the heating demand 2. Hot water mode (with hot water priority) The detector located in the secondary tank detects the hot water demand. When a draw-off is detected the controller goes to “hot water demand” mode: • The primary shunt pump starts. • The heating pump switches off. • The burner starts and the controller uses the data from the primary detector to control modulation. User-accessible parameters 1. “Hot water” setting adjustable from 20 to 90 °C. 2. “Hot water” mode: ON/OFF. 3. “Heating” mode: ON/OFF. 4. “Heating” setting adjustable from 60 to 90 °C. Parameters accessible in servicing Main default settings: - Hot water priority active. - Heating demand detection by room thermostat. -A single heating circuit. An access code is required for “service” access. For more technical information, contact your ACV dealer. ...

Otros modelos de este manual:
Calentadores de Agua - HM 101 (138.83 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría