Manual de usuario Desa, modelo CGB3930PR

Fabricar: Desa
Tamaño del archivo: 941.72 kb
Nombre del archivo: 8ea93659-cfa9-1354-f1af-45cae335515a.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


With sheet metal, you must have non-combustible material behind it. Non-combustible material must extend at least 8" up (for all models). If non-combustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). See Figure 5 for minimum clearances. IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. If Using Mantel You must have non-combustible material(s) above the fireplace opening. Non-combustible materials (such as slate, marble, tile, etc.) must be at least 1/2 inch thick. With sheet metal, you must have non-combustible material behind it. Non-combustible material must extend at least 8 inches up (for all models). If non-combustible material is less than 12", you must install the fireplace hood accessory (24" and 30" models only). Even if non-combustible material is more than 12", you may need the hood accessory to deflect heat away from your mantel shelf. See Figure 5 and Figures 6 and 7on page 9 for minimum clearances. IMPORTANT: If you cannot meet these minimum clearances, you must operate heater with chimney flue damper open. Non-Combustible Requirements for Material Distance (A) Safe Installation 12" or more Non-combustible material okay. Between 8" and 12" Install fireplace hood accessory (GA6050, GA6052, or GA6053, see Accessories,page 21). Less than 8" Non-combustible material must be extended to at least 8". See Between 8" and 12",above. If you cannot extend material, you must operate heater with flue damper open. Heat Resistant Material Figure 5 - Heat Resistant Material (Slate, Marble, Tile, etc.) Above Fireplace (A) 8 104307 OWNER’S MANUAL INSTALLATION Continued MANTEL CLEARANCES If you meet minimum clearance between mantel shelf and top of fireplace opening, a hood is not required (see Figure 6). If minimum clearances in Figure 6 are not met, you must have a hood. When using a hood there are still certain minimum mantel clearances required. Follow minimum clearances shown in Figure 7 when using hood. NOTICE: If your installation does not meet the minimum clearances shown, you must do one of the following: • operate the logs only with the flue damper open • raise the mantel to an acceptable height • remove the mantel. Floor Clearances A. If installing appliance on the floor level, you must maintain the minimum distance of 14" to combustibles (see Figure 8). B. If combustible materials are less than 14" to the fireplace, you must install appliance at least 5" above the combustible flooring (see Figure 9). Figure 6 - Minimum Mantel Clearances Without Using Hood Minimum Non- Combustible Material Minimum Non- Combustible Material Height Distances to Underside of Mantel Top of Fireplace Opening Underside of Mantel Shelf Mantel Shelf 12" (A) 18" 20" 22" 24" All minimum distances are in inches Log Set 2 1/2" 6" 8" 10" 24"/30" Models Mantel Shelf Minimum Non- Combustible Material 8" Min. 12" 15" 18" in inches 20" 2 1/2" 6" 8" 10" 12" Distances to Underside of Mantel Hood (GA6050, GA6052) Opening Underside of Mantel Shelf Figure 7 - Minimum Mantel Clearances When Using Hood All minimum distances are Log Set All Models Top of Fireplace Figure 9 - Minimum Fireplace Clearances Above Combustible Flooring 5" Min. Hearth Combustible Material Combustible Material Non-Combustible Material 14" Min. Figure 8 - Minimum Fireplace Clearances If Installed at Floor Level Continued 104307 9 CGD3924PR, CGB3924PR and CGB3930PR UNVENTED PROPANE/LP GAS LOG HEATER INSTALLATION Continued INSTALLING HEATER BASE ASSEMBLY CAUTION: Do not remove the metal data plates attached to the heater base assembly. The data plates contain important warranty information. WARNING: You must secure this heater to fireplace floor. If not, heater will move when you adjust controls. Moving heater may cause a gas leak. CAUTION: Do not pick up heater base assembly by the burner. This could damage heater. Only handle base assembly by grates. IMPORTANT:Make sure the heater burners are level. If heater is not level, heater will not work properly. Installation Items Needed • hardware package (provided with heater) • approved flexible gas hose (not provided) (if allowed by local codes) • sealant resistant to propane/LP gas, not provided • electric drill with 3/16" masonry drill bit 1. Apply pipe joint sealant lightly to male threads of the fitting to be threaded into gas regulator. Connect approved flexible gas hose to gas regulator of heater (see Figure 10). 2. Locate masonary screws in hardware package. 3. Position heater base assembly in fireplace. 4. Mark screw locations through holes in mounting flanges (see Figure 11). If installing in a brick-bottom fireplace, mark screw locations in mortar joint of bricks. 5. Remove heater base from fireplace. 6. Drill holes at marked locations using 3/16" masonry drill bit. 7. Attach base assembly to fireplace floor using two masonry screws (in hardware package) (see Figure 11). 8. Connect to gas supply. ...

Otros modelos de este manual:
Calentadores de Agua - CGB3924PR (941.72 kb)
Calentadores de Agua - CGD3924PR (941.72 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría