Iniciar sesión:
Votos - 0, Puntuación media: 0 ( )

Manual de usuario Bosch, modelo DE1821415/01

Fabricar: Bosch
Tamaño del archivo: 2.21 mb
Nombre del archivo:
Idioma del manual:ruplenfrdenl
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


A If the continuous-flow heater does not have sufficient water flow due to low water line pressure in your domestic plumbing system, remove the flow-rate limiter. B Priority circuit for the combination with electrical storage heaters: For operation with a priority circuit, a special load shedding relay BZ 45L20 (special accessory) is required. Other existing load shedding relays, with the exception of electronic load shedding relays, may malfunction. C The control electronics must be coded when operated with a load shedding relay. LED Appliance status Off Off Lights up Ready Slow flash (1/s) Appliance is heating Fast flash (4/s) Desired water temperature is not reached (water flow too high for appliance rating). E The filter upstream from the check valve in the cold water supply inlet is clogged. Remove the filter and either clean it or descale it. See Figure E 1–3. Technical dat a DE 12415 DE 1821415 DE 4151821 DE 2427415 DE 4152427 Rated output [kW] 13.2 18 21 24 27 Rated voltage [V] 400 400 400 Fuse protection [A] 20 32 40 Minimum conductor cross-section [mm2] 4 4 6 Warm water flow at rated output with temperature increase from 12 °C to 38 °C [l/min] 7.3 9.9 11.6 13.2 13.9 12 °C to 60 °C [l/min] 3.9 5.4 6.3 7.2 7.6 Start-up flow [l/min] 2.6 2.6 2.6 Start-up flow pressure * [MPa (bar)] 0.025 (0.25) 0.025 (0.25) 0.025 (0.25) Application area in water specific electric resistance at 15 °C [.cm] . 1 300 . 1 300 . 1 300 Rated pressure [MPa (bar)] 1.0 (10.0) 1.0 (10.0) 1.0 (10.0) Maximum permissible supply temperature [°C] 55 55 55 Maximum mains impedance at connection point [.] . 0.244 . 0.244 . 0.244 * The pressure loss on the mixer must also be added 9 en Operation with prewarmed water (solar heated) The continuous-flow heater can only heat prewarmed water to a max. of 60 °C. If the cold water supply exceeds a tem- Important: The cold water supply temperature must not be higher than 55 °C! If the cold water supply exceeds a temperature of 60 °C, a perature of 55 °C, the water will not be warmed any further. circuit breaker will trigger and shut the appliance off. Therefore, the residential plumbing must be equipped with a thermostatic premixer (e. g. special accessory BZ 45T20) that will limit the cold water supply temperature to a max. of 55 °C by appropriately mixing in cold water. G 1 2 A 472 99 115 236 20 100 33242 388 Special accessories ¦ Pipe kit BZ 45U20: for use of the continuous-flow heater as an under sink appliance ¦ Priority switch (load shedding relay) BZ 45L20: for operation with a priority circuit ¦ Mounting kit BZ 45K23: for surface mount installation ¦ Thermostatic premixer BZ 45T20: for installation in the domestic plumbing when using preheated water 10 en Operating instructions Please read the operating instructions carefully before you use the appliance! Safety information ¦ This appliance is intended for domestic use or for household- based non-commercial applications. Household- based applications include, e.g. usage in emp...

Otros modelos de este manual:
Calentadores de Agua - DE2427415/01 (2.21 mb)
Calentadores de Agua - DE2427415/02 (2.21 mb)
Calentadores de Agua - DE2427415/03 (2.21 mb)
Calentadores de Agua - DE4151821/01 (2.21 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría