Manual de usuario Rinnai, modelo Q175C
Fabricar: Rinnai Tamaño del archivo: 104.64 kb Nombre del archivo: 89529d2f-f951-47f1-bc54-b108464be94f.pdf
Idioma del manual:
|
|
|
|
Enlace gratuito para este manual disponible en la parte inferior de la página
Resumen del manual
supply boiler temperature °F 176 Max operating pressure psi 45 Relief valve rating MBH 375 Relief valve pressure rating psi 30 Dry weight lbs 196 Min inlet gas pressure NG "W.C. 4.0" Max inlet gas pressure NG "W.C. 10.5" Min inlet gas pressure LP "W.C. 8.0" Max inlet gas pressure LP "W.C. 14.0” Max equivalent exhaust vent length ft 80 Max equivalent combustion air vent length ft 80 Approved venting materials Polypropylene, Stainless Steel, PVC, CPVC Performance Specifications Units Fuel Type NG/LP Input MBH 1 75 Heating Capacity MBH 161 AFUE (I=B=R) % 95.7 Part Load Efficiency (EN677) % 98.5 DHW flow rate 75°F AT Gpm 4.1 Electrical Specifications Units Electrical Voltage Mains V/Hz 120/60 Electrical Voltage Controls V 24 Power Consumption Max Load W 210 Power Consumption Stand by Load W 14 Recommended Circuit breaker rating A 15 Rinnai is continually updating and improving products; therefore, specifications are subject to change without prior notice. Local, state, provincial and federal codes must be adhered to prior to installation. © 2011 Rinnai Corporation Q175C SP 2/2011 Rinnai Q175C DIMENSIONS 2.0” 50mm 18.6” 474mm 2.1” 54mm 142mm inch / mm A Height 26.8 / 680 B Width 39.4 / 1000 C Depth 15.2 / 385 D Left side / vent 19.5 / 495 E Center to center / vent and air supply 4.7 / 120 F Back / vent 10.6 / 270 G Left side / gas pipe 2.6 / 65 H Left side / supply pipe 7.3 / 185 J Left side / return pipe 17.5 / 445 K Left side / condensate pipe 20.9 / 530 L Left side / expansion pipe 23.2 / 590 N Left side / cold water pipe 34.8 / 885 O Left side / hot water pipe 37.6 / 955 P Pipe length of g 0.7 / 18 Q Pipe length of c 2 / 50 R Pipe length of e, f, k, r, and w 2.3 / 60 S Back / center of pipe c 1 / 25 T Back / Center of pipe g 1.6 / 40 U Back, / center of pipe e, f, k, r, and w 2 / 50 V Pipe length vent co-axial Pipe length vent parallel 2.6 / 65 5.8 / 147 Clearances Minimum required clearance to combustibles and non-combustibles Recom- mended service clearances inch / mm inch / mm Top 2 / 50 10 / 250 Back 0 0 Front 6 / 150 24 / 600 Left side 2 / 50 2 / 50 Right side 2 / 50 2 / 50 Floor / Ground 12 / 300 30 / 762 Vent 0 0 Rinnai Corporation • 103 International Drive • Peachtree City, GA 30269 • Toll-Free: 1-800-621-9419 • Fax: 678-364-8643 • www.rinnai.us...
|