Iniciar sesión:
Votos - 2, Puntuación media: 3.5 ( )

Manual de usuario Weil-McLain, modelo 550-141-826/1201

Fabricar: Weil-McLain
Tamaño del archivo: 2.85 mb
Nombre del archivo: wgo_boiler_manual.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


BEFORE installing, read all instructions in this manual and all other information shipped with the boiler. Perform steps in the order given. Failure to comply could result in severe personal injury, death or substantial property damage. GOLD WGOOIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 — Boiler Manual GOLD WGOOIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 — Boiler Manual GOLD WGOOIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 — Boiler Manual GOLD WGOOIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 — Boiler Manual HOMEOWNER and SERVICE TECHNICIAN — read and follow completely. Routine maintenance schedule Beginning each heating season . Call a qualified service technician to perform annual service. Daily during heating season . Check that boiler area is free from combustible materials, gasoline and other flammable vapors and liquids. Weekly during heating season . Check for and remove any obstructions to flow of combustion or ventilation air to boiler. . Check that breeching is attached between boiler and chimney. If breeching is loose or damaged, immediately turn off switch on boiler and call service technician to repair. . Check for oil leaks in oil piping and around burner. If found, immediately call qualified service technician to correct situation. . Check for water leaks in boiler and piping; also check for leaks around tankless heater plate, if installed. If found, immediately call service technician to repair. End of heating season . If tankless heater is installed, boiler will continue to operate. Check for the following: • All daily and weekly instructions listed on this page must be followed. • Burner motor may have to be oiled. Some motors are permanently lubricated and do not need additional oil. Check for oiling instructions on burner or motor. Boiler shutdown . Do not drain boiler unless exposure to freezing temperatures will occur. . Always keep manual fuel supply shut off if burner is shut down for an extended period of time. • Turn off switch at boiler and any external switch to boiler. • Close fuel valves. • Turn off water feed valve. • Cover burner to protect from dust and dampness. Part number 550-141-826/1211 GOLD WGOOIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 — Boiler Manual GOLD WGOOIL-FIRED NATURAL DRAFT WATER BOILER — SERIES 3 — Boiler Manual HOMEOWNER and SERVICE TECHNICIAN — read and follow completely. Troubleshooting Homeowners — The problems and corrections below represent common situations that can occur. There may be others not listed below. It is important always to contact a qualified service technician if you have any questions about the operation of your boiler or system. Common Problems Common Causes Possible Corrections Rapid cycling — burner turns on and off frequently. Thermostat installed where drafts or heat affect reading. Locate thermostat on inner wall away from heat sources or cool drafts. Heat anticipator in thermostat adjusted incorrectly. Adjust heat anticipator to match current draw. Refer to boiler wiring diagram. Incorrect limit setting. Have qualified service technician increase limit setting to decrease cycling. Maximum setting 220° F. Need to frequently add makeup water. Leaks in boiler or piping. Have qualified service technician repair leaks at once to avoid constant use of makeup water. Popping or percolating noise heard in boiler. Mineral deposits in sections due to constant use of makeup water, or incorrect pH. Have qualified service technician de-lime boiler, repair leaks at once to avoid constant use of makeup water and check pH (between 7.0 and 8.5). Black water condition. Oxygen corrosion due to leaks in piping. Have qualified service technician repair leaks at once to avoid constant use of makeup water and check pH (between 7.0 and 8.5). Frequent release of water through relief valve. Expansion tank sized too small or water-logged. Have qualified service technician check expansion tank operation. Metal flakes found in flueway. Contaminated combustion air supply. Remove sources of hydrocarbons in or near boiler area. (Bleaches, cleaners, chemicals, sprays, fabric softeners, paint remover, etc.) Condensation of combustion gases. Have qualified service technician check boiler operation. Some radiators or baseboard units do not heat or are noisy. Air in system. Bleed air from system through air vents in radiators or baseboard units. Low system pressure. Have qualified service technician check for leaks in boiler or piping at once. High limit set too low. Have qualified service technician adjust limit to higher setting. Domestic water from tankless heater is hot then suddenly turns cold. OR Domestic water from tankless heater is always lukewarm. Mineral deposits insulate internal waterways of heater. Have qualified service technician delime or replace coil. Boiler stop-leak compound has been added to boiler water and is insulating outside of coil. Have qualified service technician remove and clean coil and drain, and flush boiler to remove ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría