Manual de usuario Weil-McLain, modelo AFG

Fabricar: Weil-McLain
Tamaño del archivo: 1.31 mb
Nombre del archivo: f6931346-0a01-4ce4-d152-c57935b20a81.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


The installation must comply with all local codes and ordinances and with the latest revision of the National Fire Protection Standard for Oil-Burning Equipment, NFPA 31 (or CSA B139-M91). Never attempt to use gasoline as a fuel for this burner. It is more combustible than fuel oil and could result in a serious explosion, causing severe personal injury, death or substantial property damage. Read all instructions before proceeding. Follow all instructions completely. Failure to follow these instructions could result in equipment malfunction, causing severe personal injury, death or substantial property damage. W-M Part No. 550-141-754/1201 Instruction Manual - Model AFG Oil Burner Gfc". :_rr - Contents _ 'Sec&ett Prepare before installing Verify ratings..........................................................................................................3 Notice special requirements.................................................................................3 Check certifications/approvals............................................................................3 Be aware of hazard definitions............................................................................3 Verify burner specification number (Table 1).......................................................4 Prepare burner & site Inspect/prepare installation site...........................................................................5 Prepare burner......................................................................................................5 Check/adjust “Z” dimension................................................................................6 Set head position adjusting plate (“V1 ” head only)............................................7 Adjust, pipe & wire burner Mount burner on appliance..................................................................................8 Connect fuel lines.................................................................................................8 Wire burner............................................................................................................8 Startup & adjust burner Startup burner/set combustion............................................................................8 Set combustion with instruments........................................................................9 Troubleshooting....................................................................................................9 Service & maintain burner Perform annual maintenance.............................................................................10 To replace the blower wheel...............................................................................10 Replacement parts..............................................................................................11 Owner’s information and warranty....................................................................12 Sec&ett Instruction Manual - Model AFG Oil Burner _Préparé before installin^ Verify ratings Fuels U. S............No. 1 or No. 2 heating oil only (ASTM D396) Canada No 1 stove nil or No 2 furnace oil onlv Electrical Power supply.........120 vac/60 HZ/single phase Operating load....................5.8 amps maximum Motor.........Vi HP, 3450 rpm, NEMA 48M frame ...................rotation ccw when facing shaft end Ignition..........Continuous-duty-rated solid state igniter Fuel unit Pump pressure ...............See Table 1, page 4 Air tube ATC code............. Dimensions Height (maximum)...........................11 'h inches Width (maximum)............................12 7/» inches Depth (chassis only)........................6 ¥16 inches Air tube diameter..................................4 inches Check certifications/approvals • Underwriters Laboratories has certified this burner to comply with ANSI/UL 296 and has listed it for use with #1 or #2 fuel oil as specified in ASTM D396. • Low sulfur #7 and #2 fuel oils reduce heat exchanger deposits with all burners compared to the standard fuels. Reduced deposits extend the service interval for cleaning and improve the efficiency of the appliance over time. Low sulfur fuels reduce particulate and oxides of nitrogen emissions as well. The Oilheat Manufacturers'Association recommends these fuels as the preferred fuels tor this burner. • State and local approvals are shown on burner rating label (see below). • All oil burners should be installed in accordance with regulations of (he latest revision of the National Fire Protection Association Standard NFPA 31 and in complete accordance with all local codes and authorities having jurisdiction. Regulation of these authorities take precedence over the general Instructions provided in this installation manual. • For recommended installation practice in Canada, reference to CSA Standard B139-M91. Be aware of hazard definitions Notice special requirements - Concealed damage — If you ...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría