Iniciar sesión:
Votos - 3, Puntuación media: 3.7 ( )

Manual de usuario GE, modelo BTI - 65

Fabricar: GE
Tamaño del archivo: 395.74 kb
Nombre del archivo: 44bf4b65-af0f-4285-9792-ecdffe6c1eab.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


flue gas temperature °C 265 275 275 Flue gas discharge kg/h 27 55.2 53.2 Gas data butane 3+ (G30) Input* kW 17.2 21.8 29.6 Output kW 12.3 15.7 21.2 Inlet pressure mbar 30 30 30 Burner pressure mbar --- Gas consumption** kg/h 1.3 1.6 2.2 Diameter pilot orificemm0.230.230.23Diameter main orificemm1.92.22.5Max. flue gas temperature °C 265 275 275 Flue gas discharge kg/h -81.1 74.8 Gas data propane 3+ (G31) Input* kW 16.4 20.9 28.6 Output kW 11.7 15 20.4 Inlet pressure mbar 37 37 37 Burner pressure mbar --- Gas consumption** kg/h 1.2 1,5 2,0 Diameter pilot orificemm0.230.230.23Diameter main orificemm1.92.22.5Max. flue gas temperature °C 265 275 275 Draw-off capacity Storage capacity l 178 265 355 Max. temperature setting °C 80 80 80 30 min. .T=44°C l 281 396 508 60 min. .T=44°C l 405 554 713 90 min. .T=44°C l 529 713 871 120 min. .T=44°C l 652 871 1070 Continuous .T=44°C l/h 247 375 399 Heating-up time .T=44°C min. 43 42 53 30 min. .T=50°C l 248 348 447 60 min. .T=50°C l 356 488 612 90 min. .T=50°C l 465 627 777 120 min. .T=50°C l 574 767 992 Continuous .T=50°C l/h 218 330 351 Heating-up time .T=50°C min. 49 48 61 30 min. .T=55°C l 225 317 406 60 min. .T=55°C l 324 443 556 90 min. .T=55°C l 423 570 706 120 min. .T=55°C l 522 697 856 Continuous .T=55°C l/h 198 300 319 Heating-up time .T=55°C min. 54 53 67 Electrical data Power consumption W 30 Power supply VAC/Hz 230(-15/+10%) / 50 General Anodes -1 Maximum working pressure bar 8 Maximum weight kg 266 382 499 Shipping data Weight empty kg 93 122 149 Weight incl. packaging BTT / BTI kg 105 140 167 Width packaging mm 670 780 780 Height packaging mm 1690 1640 1830 Depth packaging mm 730 870 870 BTI 65BTI 85BTI 100 * Gas data Gas consumption BTI Dimensions A 1680 1585 1780 B 1510 1450 1640 D 520 645 675 E 655 770 775 G 100 130 130 K 340 340 340 M 1540 1505 1685 N 1540 1505 1685 R 295 285 285 S 1330 1280 1460 1 Cold water (external) 3/4-14 NPT 1-11.5 NPT 11/4-11.5 NPT 2 Hot water (external) 3/4-14 NPT 1-11.5 NPT 11/4-11.5 NPT 3 Gas control (internal) Rp1/2 4 Tank drain valve (internal) 3/4-14 NPT 5 T&P valve (internal) 3/4-14 NPT Dimensions in mm. All BTI water heaters receive a three years warranty on the tank and one year on parts. BTI 65BTI 85BTI 100 BTI Installation diagram Vented 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 14 Hot water outlets 17 Three way valve 18 Water tank 19 Float valve A Cold water B Hot water C Return circulation D Gas supply E Overflow pipe H Expansion vent pipe A BTI water heater should be installed in accordance with local standards and ventilation requirements (category B11BS). Further installation and connection details can be found in the Installation & Commissioning Manual. BTI Installation diagram Unvented 1 Pressure reducing valve 3 T&P valve 4 Stop valve 5 Non-return valve 6 Circulation pump 9 Drain valve 10 Gas cock 11 Isolating valve 14 Hot water outlets 15 Expansion relief valve 16 Expansion vessel A Co...

Otros modelos de este manual:
Calentadores de Agua - BTI - 65 (395.74 kb)
Calentadores de Agua - BTI - 85 (395.74 kb)
Calentadores de Agua - BTI - 85 (395.74 kb)
Calentadores de Agua - BTI - 85 (395.74 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría