Iniciar sesión:
Votos - 2, Puntuación media: 3 ( )

Manual de usuario Kenmore, modelo REVERSE OSMOSIS 625.38556

Fabricar: Kenmore
Tamaño del archivo: 1.65 mb
Nombre del archivo: 7213be10-9f21-4d74-a4b5-8bb469b60fba.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Drilling of surfaces made of stone or solid surface materials such as granite, marble, Corian or other plastic resin products TM or sinks made of porcelain and stainless steel may cause permanent, irreparable damage to the sink or countertop surface. INSTALL REVERSE OSMOSIS FAUCET 1. Locate and organize your RO faucet install parts. Refer to Figure 13. 2. Mount faucet base to sink hole until the faucet base is square against the sink surface. The rubber washer should be between the sink surface and the faucet base. 3. Tighten the toggle bolts until the base is firmly mounted to the sink surface. Do not overtighten. 4. Feed a length of 3/8" blue tubing up through the hole and connect to the 3/8" quick connect fitting on the bottom of the faucet. See Figure 14. 5. Feed a length of 1/4" red tubing up through the hole and connect to the 1/4" barb on the bottom of the faucet. See Figure 14. 6. Connect the length of 3/8" black tubing to the 3/8" barb on the bottom of the faucet. See Figure 14. faucet faucet base 1/4 turn to connect u/faucet base screw i __ ___ rubber washer toggle bolt_ _ 4__-____ _ _n°nmnaenCftc_d _ etectr°nics hole in sinkor countertop / , _. F:qJ_f:_ 3,8,, tu ,n 3/8" BLUEtubing_ / _\ Figure 13 Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com NOTE: If you ran the red reverse osmosis directly to a remote drain point, disregard and refer to instructions on page 10. 7. Mount the faucet body on to the faucet drain tubing steps 5 and 6 base, 1/4 turn. FAUCET ELECTRONICS The RO system will monitor the total product flow of the unit and also length of time the filters have been installed. The faucet base has an indicator light that flashes to inform you of the status of the RO membrane and filters. Green -RO membrane and filters are good. jJ BLUE TUBE 3/8" quick connect fitting for the blue tube BLACK TUBE 3/8" barb fitting for the black tube TUBE 1/4" barb fitting for the red tube Amber -Warning, filters need replacing. replacing, when water has been drawn, time (or 650 gallons have been used). Filters need after 6 months Figure 14 Red -RO membrane needs to be replaced. INSTALL BATTERY When the coin battery is first applied at initial start up, the LED indicator light will flash in a red, amber, green sequence. All timers and counters are reset to zero. In order to reset the time and gallon count feature, push the the button on the PWA and hold until the LED flashes and PWA board Reset button release. The battery needs to be replaced at the time of filter replacement. Use only lithium batteries (CR 2032 or equivalent). Improper placement of battery could damage electronics. Use care when inserting the battery to Battery J align it correctly Figure 15. on PWA with the proper polarity. See Figure 15 Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com HOW TO CUT AND CONNECT THE TUBES Your Reverse Osmosis Water System includes push-in fittings for quick tubing connection. Review the following instructions before connecting the tubes in the next step. Cut tubes to length 1. Use a sharp cutter or knife to cut the end of tubing. Always cut the tubing square. See Figure 16. 2. Inspect the end (about 1") of the tubing to be sure there are no nicks, scratches or other rough spots. If needed, cut the tubing again. See Figure 16. NOTE: Tubing lengths should allow for the removal of the assembly from the hanger washers for servicing. If tubing lengths are shortened for neater appearance, it may be necessary to keep the assembly on the hanger washers for service. Connect tubes 1. Push tubing through collet, until it engages the o-ring. See Figure 17. Continue pushing until the tube bottoms out against the back of the fitting. See Figure 18. A common mistake is to stop pushing when the tube engages the o-ring. This will lead to future leaks. When a 1/4" tube is fully engaged, 11/16" of the tube has entered the fitting. When a 3/8" tube is fully engaged, 3/4" of the tube has entered the fitting. See Figures 17 &18. 2. If using tubing other than tubing supplied with the system, be sure it is of high quality, exact size and roundness with a smooth surface. Disconnect Tubes 1. Push the collet inward with a finger tip. See Figure 20. 2. Continue holding collet inward while pulling the tubing out. See Figure 20. Cut tubing smooth, square with end of tubing round, with no cuts, nicks or flat spots. Tube Correctly Cut Figure 16 Caltet __f Tube Partially Engaged With Fitting Figure 17 O-Ring Tube Fully Engaged With Fitting Figure 18 Cotlet (Depress to Remove Tubing) Fitting O-Ring Seat Callet Collet and O-Ring Disconnect Tubing Figure 20 Figure 19 Questions? Call The Kenmore Water Line 1-800-426-9345 or visit KenmoreWater.com 3/8" black tubing 211 ii water supply fitting HOT COLD / 1/4" green tubing sink p-trap r UI : O Tube CONNECT YELLOW TUBE TO STORAGE TANK 1. Locate the yellow tube. One end is attached to the Reverse Osmosis filter assembly. 2. Run the other end...


Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría