Iniciar sesión:
Votos - 3, Puntuación media: 4 ( )

Manual de usuario Coway, modelo CHP-06ER

Fabricar: Coway
Tamaño del archivo: 2.73 mb
Nombre del archivo:
Idioma del manual:en
Fotos y especificaciones  Coway  CHP-06ER
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


22 23 INSTALLING METHOD Be cautious Installation place. When installing avoid bumpy areas, damp areas, and area in the reach of direct sunlight, dusty areas, water splashing areas. ¦ Installation place. Have 10Cm space between the wall and the product and install above the floor where it is solid and flat. ¦ After installation After installing use after throwing away room water more than twice. ¦ Cold water pipe Always connect to the cold water pipe. (When it is connected to hot water pipe the filter of the Water Filtration System may get damaged) ¦ Moving and installation. When moved, connect the power cord after 30minutes of installation. ¦ ¦ To secure the optimum performance of the product, consult with an installation expert for further installation. -Service center : 213-480-1600 ¦ Residuals may be left inside the filter which is used during the process of inspection when the product was manufactured. - It is not used product so feel safe to use them. Do not use the main water supply valve or hose again that is used before when installing the product. . Inside water tank CLEANING METHOD Press the cold/hot water selection switch on product front for 2 seconds to turn off, and close the main water supply valve, and pull off power cord. Drain all the water in the storage tank by using the drain hose. . Extract the cold/room water in the water tank through the tap of the cold/room water faucet and empty the water in the hot water tank through the front drainage. Open the top cover of the product pulling upward and open the sealing clips (6 areas) of the water tank. Then take out the hose and open the cover of the storage tank. 1 2 3 Installing Method Cleaning Method .. .. .. Draining out the cold/room water tank Draining out the hot water tank .. .. .. .. / Installation and Cleaning 24 25 CLEANING METHOD Separate the ceramic filter from the bottom of the storage tank cover and clean it into room water. .. 5 Wipe the inside of storage tank with a soft cloth. After installing the ceramic filter on the lower part of the storage tank cover, close the sealing clips (6 areas) of the storage tank. Close the water tank cover after inserting the hose. 7 Wash out the storage tank with the reserved water and drain it through the drain hose. 6 Close the top cover and then connect the power cord before opening the main water supply valve. After checking water extraction from the faucet of the cold/room water and hot water, press the cold/hot water selection switch in front of the product for 2 seconds for re-operation. 8 4 .. .. .. .. .. .. .. Please close the cover of the storage tank completely. Ants or other substances might get inside. .. When cleaning storage tank do not use chemicals or detergents. When the chemicals and detergents are not washed out completely it may be harmful to health. Please always keep environment clean and clean the storage tank once every two months. ¦ Cleaning Method Draining out the cold/room water tank Draining out the hot water tank .. .. Installation and Cleaning . Inside water tank 26 27 CLEANING METHOD . Gutter 1 Separating the gutter It is easily disassembled by holding the gutter after removing the gutter cover. 2 Installing the gutter After adhering the gutter closely to the front side of the product and slightly raise the gutter cover. Cleaning Method Filter Replacement and Daily Check / .. Installation and Cleaning . Filter Replacement FILTER REPLACEMENT AND DAILY CHECK Filter The vitality of product is the filter. The fraudulent filters or missing time for filter change may degrade the performance and so interrupt the filtration. If the filter is not regularly replaced, it may degrade the water quality from the product. The filter change cycle may vary within the range of expected replacement cycle depending on the feed water quality. . The period for the filter exchange is made based on 10. use in a day for house use (4 people based) and 20. use for business. ¦ ¦Estimated Time of Filter Replacement About Estimated Time of Filter Replacement The filter change cycle described above is not the filter quality warranty period but the expected cycle that the filter shows its original performance. (based on the tap water.) . The filter change cycle may be reduced for the areas with poor water quality or more applications. ¦ Part No. Names of Filter Usable Period WJNF14 Neo-sense filter WJMF14-75 WJMF14S-50 WJCFC14-POST WJCC-02 Membrane filter(CHP-06ER) Membrane filter(CHP-06EL) Fine post-carbon filter Ceramic filter 18 months 12 months 6 months 24 months 24 months The product water should be tested every 6 months to ensure that the contaminants are being reduced effectively. Please contact your local dealer or Coway to initiate this service. •This reverse osmosis system contains a replacement component critical to the efficiency of the system. Replacement of the reverse osmosis component should be one with identical specifications, as defined by the manufacturer, to assure the same...

Otros modelos de este manual:
Depuradores de agua - CHP-06ER/L (2.73 mb)
Depuradores de agua - CHP-06EL (2.73 mb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría