Iniciar sesión:
Votos - 4, Puntuación media: 3.3 ( )

Manual de usuario Culligan, modelo 2

Fabricar: Culligan
Tamaño del archivo: 49.14 kb
Nombre del archivo:
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


Never use harsh, abrasive cleaning compounds or those which contain acid, such as vinegar, bleach and similar products. 3 WARNING: Protect your water conditioner and the entire drainline from freezing temperatures. DANGER: If your unit should freeze, do not attempt to disassemble it. Call your Culligan Dealer. 4 The timer is very accurate. Keep time-of-day setting correct to assure recharging at the proper time. 5 Should service, adjustment or trouble-shooting information be needed which is not covered in this Use and Care Guide, refer to the appropriate Installation Manual for your model. If you do not have this material, it may be obtained from your independently operated Culligan dealer. To clean out the salt storage tank A periodic clean-out of the Salt Storage Tank is necessary to keep your Culligan Water Conditioner at peak operating efficiency. Do it at least every 2 years when the salt supply is low. Follow these step-by-step procedures: Tools needed: Scoop Clean, bucket-size container Phillips-head screwdriver Garden hose Household scrub brush or sponge 1 Remove the salt storage tank cover and the cap from the brine valve chamber. 2 Lift the brine valve out of the brine valve chamber and set aside in an upright position. 3 If you’d like to save any clean, dry salt remaining in the tank, remove it and place it in a clean container. 4 Using the scoop, dig out and discard as much remaining salt, water and debris as possible. 5 Remove the brine valve chamber by removing the screws on either side of the salt tank. 6 Lay the salt tank on its side and direct a brisk stream of water from your garden hose to its inside to rinse out all residue. 7 Using a household scrub brush and a mild soapy solution, clean the salt plate. This will complete the tank cleaning. 8 Stand salt tank upright. Place brine valve chamber in position and affix with screws. 9 Insert the brine valve into the chamber and replace brine valve chamber cap. 10 Fill the salt storage tank with 4 to 6 inches of water. 11 Fill the tank with salt to within a few inches from the top. 12 Replace salt storage tank cover. Before you call for service . . . If you unexpectedly experience hard water, make these simple checks before calling your Culligan Man. One of the following conditions may be the reason for your interruption of service. IMPORTANT: If any of the following conditions are found, the water conditioner should be manually recharged according to instructions on page 7 after you have corrected the condition. POWER SUPPLY Check your power supply cord. Is it plugged fully into the electric outlet? Be certain that the outlet does not have a wall switch which has been turned off. Reset conditioner to proper time of day and then plug in. BLOWN FUSE Check the house fuse or circuit breaker panel. Replace a blown-out fuse or reset an open circuit breaker. POWER FAILURE Any interruption in your power supply, or time changes — such as daylight savings — will disrupt your conditioner’s recharge schedule by causing the timer to run off schedule. Reset timer to proper time of day. SALT SUPPLY Check it. Refill if necessary and wait approximately four hours for the salt to dissolve before initiating a recharge cycle. BY-PASS VALVES Check to see if they are in the proper position. Cul-Flo-Valv® by-pass, if used, should be in the “Push for Soft Water” position. If hand valves are used, see that inlet and outlet valves are opened and that the bypass valve is closed. INCREASED USAGE Guests, family additions, new water-using appliances, etc. all will result in more water usage and will require more capacity from your conditioner. You can reprogram your recharging schedule by following the directions on adjustments on pages 6 and 7. Call your Culligan Man for advice and save a service call. NO WATER If you aren’t getting any water flow at all, make sure your water supply is working. Open a tap ahead of the conditioner (outside tap) to see if you have any water pressure. Check the by-pass valve. If it is the Service (soft water) position, put it into by-pass and call your Culligan dealer for service. CONTINUOUS FLOW TO DRAIN If water runs to drain continuously, check to make sure unit is not in recharge. If it is recharging, allow unit to finish cycle, then reset time of day if necessary. If the unit is not in recharge, unplug electrical cord, place the valve in bypass, and contact your Culligan dealer for service. SALT BRIDGING Salt “bridging” occurs when a space is formed between the salt and the water preventing the salt from dissolving in the water to make brine. No brine — no soft conditioned water! High humidity and/or use of some brands of purified salt products may cause a salt bridge to form. The best way to check and eliminate a salt bridging problem is to take a broom handle or similar instrument and make a mark 32 inches from the end. Then carefully begin to probe down through the salt with the instrument. Should an obstruction be found before the ...

Otros modelos de este manual:
Depuradores de agua - 2M (49.14 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría