Iniciar sesión:
Votos - 3, Puntuación media: 3 ( )

Manual de usuario Everpure, modelo HAZER 2

Fabricar: Everpure
Tamaño del archivo: 745.14 kb
Nombre del archivo: Arena_Hazer2_UM.pdf
Idioma del manual:en
Enlace gratuito para este manual disponible en la parte inferior de la página



Resumen del manual


This can lead to reduced lamp life and increased mechanical wear. Be sure to power off fixture before conducting maintenance. . Unplug fixture from power. . Use a vacuum or air compressor and a soft brush to remove dust collected on external vents. . Clean all glass when the fixture is cold with a mild solution of glass cleaner or Isopropyl Alcohol and a soft lint free cotton cloth or lens tissue. . Apply solution to the cloth or tissue and drag dirt and grime to the outside of the lens. . Gently polish optical surfaces until they are free of haze and lint. The cleaning of external optical lenses and/or mirrors must be carried out periodically to optimize light output. Cleaning frequency depends on the environment in which the fixture operates. Damp, smoky or particularly dirty surroundings can cause greater accumulation of dirt on the unit’s optics. Clean with soft cloth using normal glass cleaning fluid. Clean the external optics at least every 20 days. Clean the fixture at least every 30/60 days. Important Icon - B&W - 200x201.gif Always dry the parts carefully after cleaning them. CAUTION B&W Triangle - 200x184.gif Never spin a fan using compressed air. Warning! All haze machines are prone to clogging due to the thick consistency of the fog liquid and the high temperature at which it vaporizes. However, a properly maintained fog machine should provide years of reliable use. Cleaning your fog machine regularly will help reduce costly replacement and repair charges. Notes Icon 03 - 200x227.gif Maintenance Do not allow the haze machine to become contaminated. After every 40 hours of continuous operation, it is recommended to run a cleaning solution composed of 80% distilled water and 20% vinegar through the system to prevent the accumulation of particulate matter in the heating element. The recommended cleaning procedure is as follows: 1. Empty all fog liquid from the machine. Add cleaning solution to tank. Plug unit in and begin warm up. 2. Run the unit in a well-ventilated area until the tank is almost empty. Do not allow the pump to run dry. 3. Replace nozzle. 4. Cleaning is now complete. Refill with fog liquid. Run the machine briefly to clear any cleaning solution from the pump and heater. 5. Do not operate the machine without liquid at any time. Storage 1. When storing the machine, run distilled water (not tap water) through the system as described in the cleaning regiment above. This will help avoid any particles condensing inside the pump or heater. 2. It is strongly recommended to test-run the machine on a monthly basis in order to achieve its best hazing condition. CAUTION B&W Triangle - 200x184.gif Never place the hazer on any flammable material (i.e. carpet, fabric etc.) during operation. All fog/hazer machines should always be on a non-flammable surface, such as concrete or tile. CAUTION B&W Triangle - 200x184.gif Depending on the amount of haze generated, all haze machines may set off smoke detectors. Fixture Linking You will need a serial data link to run light shows of one or more fixtures using a DMX controller or to run synchronized shows on two or more fixtures set to a master/slave operating mode. The combined number of channels required by all the fixtures on a serial data link determines the number of fixtures the data link can support. Fixtures on a serial data link must be daisy chained in one single line. To comply with the EIA- 485 standard, no more than 32 fixtures should be connected on one data link. Connecting more than 32 fixtures on one serial data link without the use of a DMX optically-isolated splitter may result in deterioration of the digital DMX signal. Important Icon - B&W - 200x201.gif Maximum recommended serial data link distance: 500 m (1640 ft) Maximum recommended number of fixtures on a serial data link: 32 Data Cabling To link fixtures together you must obtain data cables. You can purchase CHAUVET-certified DMX cables directly from a dealer/distributor or construct your own cable. If you choose to create your own cable please use data-grade cables that can carry a high quality signal and are less prone to electromagnetic interference. DMX Data Cable Use a Belden© 9841 or equivalent cable which meets the specifications for EIA RS-485 applications. Standard microphone cables cannot transmit DMX data reliably over long distances. The cable must have the following characteristics: Type: shielded, 2-conductor twisted pair Maximum capacitance between conductors: 30 pF/ft Maximum capacitance between conductor and shield: 55 pF/ft Maximum resistance: 20 ohms/1000 ft Nominal impedance: 100 ~ 140 ohms Cable Connectors Cabling must have a male XLR connector on one end and a female XLR connector on the other end. DMX connector configuration To avoid signal transmission problems and interference, it is always advisable to connect a DMX signal terminator. Resistance 120 ohm . W between pin 2 (DMX -) and pin 3 (DMX +) on the output of the last fixture. 2 3 1 2 3 1 2 3 1 OUTPUT...

Otros modelos de este manual:
Depuradores de agua - HAZER 2 (745.14 kb)
Depuradores de agua - HAZER 2 (745.14 kb)

Comentarios



Tu reseña
Tu nombre:
Introduzca dos números de la imagen:
capcha





Categoría